SWSherine Shafik Wahba

Sherine Shafik Wahba

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sherine Shafik Wahba has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diagnostic accuracy of different keratoconus detection indices of pentacam in paediatric eyes

    by Ahmed Osama Hashem, Bassem Fayez Aziz, Sherine Shafik Wahba, Maged Maher Roshdy, Amr Ismail Elawamry

    Objective: No diagnostic gold standard for keratoconus in children and adolescents exists. Our objective was investigating the diagnostic accuracy of various indices for keratoconus (KC) detection in paediatric eyes.Methods: All retrievable data of significance from 432 normal right paediatric eyes and 48 eyes of paediatric KC and forme fruste KC (FFKC), imaged by use of a rotating Scheimpflug camera (Oculyzer II, Pentacam HR) between December 2013 and October 2018 at Watany Eye Hospitals, Cairo, Egypt, including Scheimpflug images data, were collected. The area under the receiver operating characteristic curve (AUROC) was calculated for different indices in this retrospective descriptive study.Results: All 36 tested indices showed discriminative power differentiating KC and FFKC from normal corneas (AUROCP-value 0.05).Conclusions: The 8 most useful rotating Scheimpflug imaging indices for KC detection in paediatric eyes are CAIRO 8 followed by ART max and avg, PPI max and avg, BE BFTE, KI, TKC, and IHD.


  • Customized miniflap for a nondissected flap island during femtosecond laser–assisted laser in situ keratomileusis

    by Abdallah K. Hassouna, Sherine S. Wahba, Marian S. Md Hermina, Sameh N. Boptom Samy

    Three cases of a rare complication that occurred during femtosecond laser–assisted laser in situ keratomileusis are reported. An anterior chamber gas bubble escaped between the cornea and the cone through the canal, which lead to a nondissected island. A new technique, a customized miniflap that could be applied in the same session to treat the nondissected island is described. The results were promising because the flaps were lifted easily with no complications, confirmed by the postoperative visual acuity, the regularity index, and anterior segment optical coherence tomography.

  • Open Access

    Pentacam HR Indices Variation in Normal Corneas with Different Corneal Thickness

    by Maged Maher Salib Roshdy, Sherine Shafik Wahba, Rania Serag Elkitkat, Nermine Said Madkour, Ramy Riad Fikry

    Purpose. To evaluate the effect of variable corneal thickness on Pentacam HR diagnostic indices in normal corneas.Methods. Retrospective study was conducted at Al Watany Eye Hospital, Cairo, Egypt. Consecutive 160 eyes of young myopic subjects without KC were evaluated using Pentacam HR (WaveLight Allegro Oculyzer II, Erlangen, Germany). The elevation- and thickness-based indices were recorded. Enrolled corneas were categorized into three groups according to TCT quartiles; group 1 (39 eyes) included corneas with TCT 564 µm. The possible effect of pachymetry on Pentacam HR indices was assessed using partial correlation tests.Results. In normal corneas, back elevation from best fit sphere (BE from BFS) and that from best fit toric ellipsoid (BFTE) were the elevation indices that showed statistically significant differences among groups (P=0.013and0.019, respectively). Regarding pachymetric indices, maximum pachymetry progression index (PPI max) showed statistical significance (P=0.001). Partial correlations, after excluding age and refractive error effects, showed that TCT was correlated with BE from BFS, BE from BFTE, and PPI max (P=0.001,0.001,0.002, respectively).Conclusions. Some Pentacam HR indices varied with different corneal thickness in normal corneas. This necessitates inclusion of pachymetric subgroups in the normative database. The use of the more robust indices (average pachymetry progression index and front elevations) is recommended in relatively thin or thick corneas.


  • Open Access

    Topographic Asymmetry Indices: Correlation between Inferior Minus Superior Value and Index of Height Decentration

    by Sherine S. Wahba, Maged M. Roshdy, Ramy R. Fikry, Mona K. Abdellatif, Abdulrahman M. Abodarahim

    Purpose. To investigate the correlation between decentration index (index of height decentration, IHD) automatically calculated by the Pentacam HR software and the manually calculated inferior minus superior (I‐S) value.Setting. Al Watany Eye Hospital, Cairo, Egypt.Methods. In a retrospective study, history taking, clinical examination, and rotating Scheimpflug camera scanning (by Oculyzer II equivalent to Pentacam HR) were done to 128 eyes: 82 normal, 24 forme fruste keratoconus FFKC (apparently normal cornea with evident keratoconus in the fellow eye), and 22 keratoconus (KC). All cases of corneal scars or previous corneal surgeries were excluded. The (I‐S) value was calculated manually from 10 points astride the horizontal meridian. The IHD is calculated automatically by the device software 1.17r119.Results. The mean (±SD) of (I‐S) value in normal, FFKC, and KC eyes were 0.30 ± 0.93, 0.11 ± 2.03, and 4.62 ± 3.89, respectively, and those of IHD were 0.008 ± 0.004, 0.011 ± 0.005, 0.066 ± 0.067, respectively. The two indices were highly correlated (p<0.0001) with a correlation coefficient (r2 = 0.874). Deduced regression formulae linking the two indices were calculated.Conclusions. The two topographic decentration indices are highly correlated. Deduced formulae were proposed linking them.


  • Open Access

    New corneal assessment index from the relational thickness and other OCULUS values (CAIRO Index)

    by Maged M Roshdy, Sherine S Wahba, Ramy Riad Fikry

    Purpose: The aim of this study was to find indices for keratoconus (KC) detection with higher sensitivity and specificity than the currently available ones with the rotating Scheimpflug imaging (Oculyzer I, Pentacam) software. Patients and methods: Data of 103 normal and 73 KC eyes imaged by Oculyzer I, including slit-lamp examination, refraction, Scheimpflug images, and follow-up data were collected. Logistic regression was done to find new indices with higher area under receiver operating characteristic curves using the currently available ones. Results: The Corneal Assessment Index from Relational thickness and other OCULUS Values 9 (CAIRO 9) index, deduced from the Ambrosio relational thickness-maximum and the anterior elevation at thinnest point from 9 mm best-fit sphere, and the CAIRO 8, deduced from Ambrosio relational thickness-maximum and anterior elevation at thinnest point from 8 mm best-fit sphere, have a very high area under receiver operating characteristic curves for KC detection (0.997 and 0.995, respectively). Conclusion: New corneal assessment index is deduced with better sensitivity and specificity for KC detection.


  • Open Access

    Effect of Age on Pentacam Keratoconus Indices

    by Maged Maher Salib Roshdy, Sherine Shafik Wahba, Rania Serag Elkitkat, Amira Maurice Hakim, Ramy Riad Fikry

    Purpose. To assess the effect of age on elevation and pachymetric Pentacam keratoconus (KC) detection indices, and the need to adjust normative values accordingly. Methods. In a retrospective study, 95 eyes of myopic normal subjects without KC were evaluated using the OCULUS Pentacam, with an age range of 17.4 to 46.8 years. Subjects were categorised into three groups according to their age: the first included those younger than 21 years (19 eyes), the second was for the age range of 21–40 years (65 eyes), and the third comprised subjects older than 40 years (11 eyes). Results. There were statistically significant differences among the three groups regarding many elevation indices: AE from BFS, PE from BFS, and PE minus AE from BFS (P=0.003, 0.010, and <0.001, resp.), and pachymetric indices: PPI avg, PPI max, ART avg, ART max, and diagonal decentration of the thinnest point (P=<0.001, 0.024, 0.003, 0.026, and 0.026, resp.). On comparing subjects below 21 years to those above 40 years, there was a statistically significant decrease of both PE from BFS and PE minus AE (P=0.005 and <0.001, resp.) and statistically significant increase in AE from BFS (P=0.001). Conclusions. Age is an important determinant of elevation indices, significantly altering their normative values. The use of the more robust pachymetry, rather than elevation, indices is recommended in subjects below 21 or above 40 years of age.


  • Open Access

    Cap-preserving SMILE Enhancement Surgery

    by Ahmed N. Sedky, Sherine S. Wahba, Maged M. Roshdy, Nermeen R. Ayaad

    Different enhancement procedures have been suggested for reduction of residual refractive errors after SMILE. The aim of this study is to evaluate an improved cap-preserving technique for enhancement after SMILE (Re-SMILE). A retrospective case series was conducted at Eye subspecialty center, Cairo, Egypt on 9 eyes with myopia or myopic astigmatism (spherical equivalent – 8.0 and − 12.0D). undergoing SMILE procedure and needed second interference. This was either because the more myopic meridian was more than − 10.0 D and therefore planned to have two-steps procedure (six eyes) or because of under correction needing enhancement (three eyes). Assessment after the primary SMILE procedure was conducted at 1 day, 1 week, 1 month and 3 months postoperatively. Assessment after Re-SMILE was conducted at 1 day, 1 week, 1 month, 3 months, 6 months and 1 year postoperatively. The assessments included full ophthalmic examination, objective and subjective refraction, and rotating Scheimpflug camera imaging. Preoperatively, the mean refractive spherical equivalent (MRSE) values were: − 9.36 ± 0. 89. After primary SMILE it was − 2.18 ± 0.71. After Re-SMILE it was − 0.13 ± 0.68. MRSE was significantly improved after both procedures (P < 0.01). The safety index of primary SMILE cases was 1.65 ± 0.62 and for Re-SMILE 1.13 ± 0.34 and the efficacy index was 1.14 ± 0.24 after primary SMILE and 1.11 ± 0.26 after Re-SMILE. Centered cap-preserving Re-SMILE is an effective procedure in reducing residual refractive errors after primary SMILE in high myopes.


  • Open Access

    Dellen formation as a complication of subconjunctival silicone oil following microincision vitrectomy

    by Mohamed M Mahgoub, Maged M Roshdy, Sherine S Wahba

    Purpose: To study the subconjunctival silicone oil (SCSO) parameters associated with dellen formation following microincision vitrectomy (MIV). Patients and methods: This was a case–control study of 20 eyes with SCSO following MIV. Ten of them suffered postoperative dellen formation. Dellen occurrence, their sizes, number of loci, and distance between SCSO and the limbus were recorded. The outcome after silicone-oil removal was evaluated. Results: The SCSO was at 3.1±1.2 mm from the limbus. All cases with dellen had SCSO within 2 mm of the limbus (PP=0.414; sex, P=0.656; laterality, P=1; indication for pars plana vitrectomy, P=0.655; instrument gauge, P=0.211; circumference involved by SCSO, P=0.252). All the dellen healed after surgical evacuation of SCSO (PConclusion: Dellen can be associated with MIV secondary to SCSO near the limbus. Resolution with scarring occurred following SCSO evacuation. Therefore, SCSO should be evacuated as early as possible to avoid long-term peripheral corneal morbidity.


  • Open Access

    Microcapillary sign of flap alignment in femtosecond laser-assisted in situ keratomileusis

    by Fathy Fawzy, Sherine S Wahba, Nader Fawzy

    Microcapillary sign of flap alignment in femtosecond laser-assisted in situ keratomileusis Fathy Fawzy,1,2 Sherine S Wahba,1,3 Nader Fawzy1,4 1Al Watany Eye Hospital, 2Ophthalmology Department, Military Medical Academy, 3Ophthalmology Department, Ain Shams University, Cairo, Egypt; 4Sehkraft Augenzentrum, Cologne, Germany We present an observational sign that ensures perfect alignment during femtosecond laser-assisted in situ keratomileusis (FS LASIK). Alignment is assured when a microsponge is used to dry the flap and the area of dryness exceeds the area of direct touch of the microsponge. The area might even reach the whole circumference of the flap at the first touch. This sign of alignment can be explained by microcapillary action. This sign was not elicited in flaps created by a microkeratome. Keywords: capillarity, femtosecond LASIK flap, corneal flap alignment


  • Open Access

    Rotating Scheimpflug Imaging Indices in Different Grades of Keratoconus

    by Sherine S. Wahba, Maged M. Roshdy, Rania S. Elkitkat, Karim M. Naguib

    Purpose. To evaluate accuracy of various Keratoconus (KC) screening indices, in relation to Topographic Keratoconus (TKC) grading.Setting. Al Watany Eye Hospital, Cairo, Egypt.Methods.Data of 103 normal (group 1) and 73 KC eyes (group 2), imaged by Pentacam (branded as Allegro Oculyzer), were analysed.Group 2was divided into2a: 14 eyes (TKC = 1, early KC),2b: 25 eyes (TKC = 1 to 2 or 2, moderate KC), and2c: 34 eyes (TKC = 2 to 3 up to 4, severe KC). Participants were followed up for six years to confirm diagnosis. Area under the receiver operating characteristic curve (AUROC) was calculated for evaluated curvature, elevation, and pachymetry indices with various reference shapes at different diameters.Results. When comparing normal to KC eyes, ten indices had significantly higher AUROC. Only five of them had significantly higher AUROC in early KC compared to normal corneas: Pachymetry Progression Index- (PPI-) Maximum (Max), Ambrósio’s Relational Thickness- (ART-) Max, PPI-Max minus PPI-Minimum (Min), central corneal thickness (CCT), and diagonal decentration of thinnest point from the apex (AUROC = 0.690, 0.690, 0.687, 0.683, and 0.674, resp.).Conclusion. Generally, ten pachymetry and elevation-based indices had significantly higher AUROC. Five indices had statistically significant high AUROC when comparing early KC to normal corneas.