Radiation Dose to the Lens Using Different Temporal Bone CT Scanning Protocols
Authors:
- Y. NiuYNY. Niu
- Z. WangZWZ. Wang
- Y. LiuYLY. Liu
- Z. LiuZLZ. Liu
- V. YaoVYV. Yao
Open Access
- 5 November 2009
- journal article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 31 (2) , 226-229
Abstract
BACKGROUND AND PURPOSE: Temporal bone CT is performed frequently in clinical practice. At the same time, the eye lens are exposed to ionizing radiation without any useful diagnostic information delivered. Our aim was to investigate the radiation dose to the lens of the eye by using temporal bone CT scanning with different protocols. MATERIALS AND METHODS: Direct axial and coronal CT by using a conventional sequential scanning mode (140 kV, 220 mAs/section, 1.25-mm thickness, 1.25-mm increment, 16 × 0.625 mm collimation, the glabellomeatal line as a scanning baseline), a routine helical scanning mode (140 kV, 220 mAs/section, 0.315 pitch, 0.67-mm thickness, 0.33-mm increment, 16 × 0.625 collimation, the orbitomeatal line as a scanning baseline), and a modified helical scanning mode (acanthiomeatal line as a scanning baseline; other parameters, same as above) was performed on an exsomatized cadaveric head. CTDIvol and DLP were recorded for each scanning mode, and effective doses were calculated. Organ doses for the lens were measured with TLDs. RESULTS: When the sequential scanning mode was used, the gross effective dose was 1.21 mSv and the organ dose to the lens was 50.96 and 1.73 mGy, respectively, for direct axial and coronal imaging. The effective dose was 0.803 mSv in routine helical scanning, while the lens dose was 40.17 mGy. With the modified helical scanning mode, the effective dose was as same as that for the routine helical scanning, but the lens dose was reduced significantly to 10.33 mGy. CONCLUSIONS: The effective doses resulting from sequential axial and coronal scanning were 1.51 times higher than the dose from helical scanning, and the lens dose was 1.31 times higher. With the modified helical scanning mode, thinner section images could be used to reformat axial, coronal, and sagittal images with a further 74.3% reduction in lens dose beyond that achieved with the conventional helical protocol.Keywords
This publication has 13 references indexed in Scilit:
- Imaging of Complications of Acute Mastoiditis in ChildrenRadioGraphics, 2003
- High-resolution Petrous Bone Imaging Using Multi-slice Computerized TomographyActa Oto-Laryngologica, 2001
- Patient doses from CT in New Zealand and a simple method for estimating effective doseBritish Journal of Radiology, 1996
- Radiation dose to the lens from computed tomography scanning in a neuroradiology departmentBritish Journal of Radiology, 1995
- Comparison of two methods for assessing patient dose from computed tomographyBritish Journal of Radiology, 1994
- High-resolution CT of the temporal bone: a modified baseline.Radiology, 1992
- Patient dose and associated risk due to radiological investigation of the internal auditory meatusBritish Journal of Radiology, 1991
- Determinations of organ doses and effective dose equivalents from computed tomographic examinationBritish Journal of Radiology, 1991
- Radiation Doses to the Lens of the Eye During Computerised Tomography of the Orbit; A Comparison of Four Modern Computerised Tomography UnitsAustralasian Radiology, 1990
- Calcification of the transverse ligament in calcium dihydrate deposition disease (CPPD)Neuroradiology, 1985