Ultrasound Assessment of Gastric Emptying in Premature Infants Treated With Non‐Invasive Ventilatory Support
Authors:
- 26 April 2021
- journal article
- research article
- Published by Wiley in Journal of Pediatric Gastroenterology and Nutrition
- Vol. 73 (2) , 197-202
Abstract
Background: Nasal continuous positive airway pressure (CPAP) introduces positive pressure of air into both the trachea and stomach, which may affect gastric emptying. The rate of gastric emptying can be estimated by ultrasound (US) in neonates by two validated techniques: “antral cross‐sectional area” (ACSA, two‐dimensional estimate of the surface area at the gastric antrum), and “spheroid gastric volume” (spheroid, three‐dimensional estimate of the stomach volume).Objective: To compare gastric emptying rates in neonates on machine‐derived nasal CPAP (MD‐nCPAP, Avea and RAM cannula) with those on bubble CPAP (bCPAP, Fisher Paykel and Babi.Plus nasal prongs).Methods: Ultrasound measurements of the amount of the milk in the stomach were performed before feeding and at 1, 2, and 3 hours after the start of feeding, using both the ACSA and spheroid methods. Rates of gastric emptying were calculated during the “early” (1–2 hours) and “late” (2–3 hours) phases after feeding.Results: We recruited 32 infants (25–34 weeks gestational age, full enteral tube feedings, on nasal CPAP). Seventeen infants were treated with MD‐nCPAP (median birth weight 1015 g [interquartile range (IQR): 870–1300], gestational age 28 weeks [IQR: 27–29], postnatal age 20 days [IQR: 14–28]), whereas 15 infants were treated with bCPAP (median birth weight 960 g [IQR: 855–1070], gestational age 27 weeks [IQR: 26–28], postnatal age 17 days [IQR: 15–25]). Gastric emptying rates (% emptied/min) were significantly faster in the “early” compared to the “late” phase for all infants. There were no significant differences in the rates of gastric emptying (either “early” or “late”) or volumes of gastric residuals between infants receiving MD‐nCPAP or bCPAP, measured by either method. Although no feeding intolerance was seen in either group, the volumes of residual gastric contents measured by both methods were higher than the volumes traditionally considered abnormal when obtained by gastric tube aspiration.Conclusions: Gastric emptying is faster during the “early” compared to the “late” phase. Gastric emptying rates are not different in infants receiving MD‐nCPAP versus bCPAP. The presence of large residual gastric contents in infants who are tolerating feedings challenges the value of traditional gastric aspiration for the assessment of feeding tolerance in infants.Keywords
All Related Versions
This publication has 29 references indexed in Scilit:
- A Randomized Controlled Trial of Post-extubation Bubble Continuous Positive Airway Pressure Versus Infant Flow Driver Continuous Positive Airway Pressure in Preterm Infants with Respiratory Distress SyndromeThe Journal of Pediatrics, 2009
- Continuous Positive Airway Pressure and Noninvasive VentilationClinics in Perinatology, 2007
- Gastric emptying in very-low-birth-weight infants treated with nasal continuous positive airway pressureThe Journal of Pediatrics, 2004
- Gastric Residual (GR): Reliability of the Measurement. 888Pediatric Research, 1997
- Gastric emptying in preterm infants.Archives of Disease in Childhood - Fetal and Neonatal Edition, 1994
- Ultrasonic assessment of gastric emptying in the preterm infant.Archives of Disease in Childhood, 1993
- Benign gaseous distension of the bowel in premature infants treated with nasal continuous airway pressure: a study of contributing factors.American Journal of Roentgenology, 1992
- Gastric emptying with gastro-oesophageal reflux.Archives of Disease in Childhood, 1987
- Randomized controlled trial of very early continuous distending pressure in the management of preterm infantsEarly Human Development, 1987
- Gastric emptying in children: unusual patterns detected by scintigraphyAmerican Journal of Roentgenology, 1983