DKDalibor Kurepa

Dalibor Kurepa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dalibor Kurepa has a total of 73 co-authors. Here are the top co-authors by number of shared publications:

  • Barry Weinberger

    Division of Neonatology, Cohen Children's Medical Center, New Hyde Park, New York, USA

    5 shared publications
  • Vitaliya Boyar

    Pediatrics, Cohen Children's Medical Center Division of Neonatology, New Hyde Park, New York, USA

    4 shared publications
  • Alla Zaytseva

    Northwell Health, Cohen Children’s Medical Center, Division of Neonatology, New Hyde Park, USA

    3 shared publications
  • Barry Weinberger

    Department of Pediatrics, Division of Neonatal-Perinatal Medicine, Cohen Children’s Medical Center, Northwell Health, New Hyde Park, USA

    3 shared publications
  • Gangajal Kasniya

    Division of Neonatology, Cohen Children's Medical Center, New Hyde Park, New York, USA

    3 shared publications
  • Jane Cerise

    Feinstein Institutes for Medical Research Manhasset New York USA

    3 shared publications

Latest Publications

  • Open Access

    Lung Ultrasound-Guided Non-Fiberobronchoscopic Bronchoalveolar Lavage for Neonatal Atelectatic Pulmonary Disease Treatment: Clinical Practice Guidelines Based on International Expert Consensus

    by Jing Liu, Ya-Li Guo, Peng Jiang, Xian Zhang, Bi-Ying Deng, Zun-Jie Liu, Xiao-Xiao Wang, Yuan Hong, Xiao-Ling Ren, Meng-Ru Zhao, et al.

    Severe pulmonary diseases, including atelectasis, pneumonia, and meconium aspiration syndrome, are major causes of neonatal respiratory distress, weaning difficulties, ventilator or oxygen dependence, prolonged oxygen requirements, extended hospitalization, and poor prognosis. The lack of simple and effective treatment strategies seriously endangers the survival and health of newborns, particularly premature infants. Recent advances in lung ultrasound (LUS) technology have made LUS-guided non-fiberobronchoscopic bronchoalveolar lavage (NFB-BAL) a promising solution. This approach addresses the limitations of conventional BAL in neonates by enabling accurate diagnosis, precise lesion localization, and dynamic procedural monitoring, hence reducing complications. Based on international expert consensus, these guidelines were developed to improve knowledge and promote the application of this technology and enhance operational standardization to ensure its effectiveness and safety. These guidelines contain 17 recommendations on 13 key clinical issues for reference and implementation in clinical practice. The wide application of these guidelines is expected to help significantly improve the prognosis of critically ill newborns with atelectatic pulmonary diseases.

  • Predictors of extubation success for premature infants

    by Victoria M. Scarpelli, Stephanie G. Galanti, Iels Aan Jibu, Alla Zaytseva, Dalibor Kurepa, Barry Weinberger

    Objective We aimed to determine whether clinical variables predict the success of extubation for premature infants. Study design Using variables preceding 320 extubations of infants ≤30 weeks or ≤1250 g at birth, we built predictive models for success at 1-, 3-, and 7-days using machine learning algorithms. We also determined whether lung ultrasound (LUS) scores (n = 15) were associated with success, or predicted success, of extubation. Result Of 84 factors considered, nine were associated with success at 1 day, seven at 3 days, and six at 7 days. The accuracies of the predictive models were 78–84%. Median LUS scores were significantly lower preceding successful extubations (at 3 days) but not correlated with the findings of the predictive models. Conclusion We devised robust models for predicting extubation success based on clinical antecedents. Further study is needed to determine whether LUS can further improve prediction of extubation readiness.

  • Open Access

    Outcomes, safety and health economics of introduction of video laryngoscopy-assisted less invasive surfactant administration

    by Venkata Gupta, Barry Weinberger, Stephanie G. Galanti, Jimikumar Patel, Gangajal Kasniya, Dalibor Kurepa

    Background: Less invasive surfactant administration (LISA) is associated with better outcomes than InSurE (Intubation-Surfactant administration-Extubation). Video-laryngoscopy (VL) facilitates intubation in neonates, however safety and cost-effectiveness of VL-assisted LISA have not been evaluated. Methods: We compared the outcomes of infants receiving VL-assisted LISA (n = 67) with a historical cohort of infants who received InSurE (n = 52). Secondary aims were to evaluate safety and cost-effectiveness. Results: VL-assisted LISA was associated with reduced duration of non-invasive ventilation (NIV), reduced duration of oxygen therapy, reduced composite days on NIV and mechanical ventilation (MV), and shorter NICU stay with lower hospital costs for infants ≥29 weeks GA, compared to InSurE. In the VL-assisted LISA group, 66% of the tracheal catheters were placed on the first attempt and 16% of infants displayed desaturation during placement. Conclusion: In infants ≥29 weeks GA, VL-assisted LISA reduced exposure to NIV, oxygen, NIV and MV combined, length of stay, and cost of care compared to InSurE.


  • Open Access

    Lung Ultrasound Assessment of Regional Distribution of Pulmonary Edema and Atelectasis in Infants with Evolving Bronchopulmonary Dysplasia

    by Jimikumar Patel, Barry Weinberger, Margaret Pulju, Stephanie G. Galanti, Gangajal Kasniya, Venkata Gupta, Dalibor Kurepa

    Background: Preterm infants are at risk for bronchopulmonary dysplasia (BPD) due to prolonged respiratory support. Studies have described differences in the regional distribution of lung ventilation (non-dependent (NDL) vs. dependent (DL)). The aim of this study was to use LUS to compare regional distribution of pulmonary edema and atelectasis in infants with evolving BPD. Methods: We prospectively performed LUS in premature infants with evolving BPD. On each side, three lung areas (NDL/anterior, lateral, and DL/posterior) were examined for the presence of pulmonary edema and atelectasis. Pulmonary edema scores were assigned based on the number of B-lines, and atelectasis scores were assigned based on the presence/absence of atelectasis. Results: 38 premature infants were enrolled. The NDL showed more pulmonary edema and atelectasis compared to the DL (p = 0.003, p = 0.049, respectively) and compared to the lateral lung (p =< 0.001, p = 0.004, respectively). There was no difference between the lateral and DL (p = 0.188, p = 0.156, respectively). There was no difference between the right and the left lung (p = 0.223, p = 0.656, respectively). Conclusions: In this cohort of preterm infants with evolving BPD, lung disease was unevenly distributed, with more pulmonary edema and atelectasis in the NDL regions compared to the DL or lateral regions.


  • Video laryngoscopy-assisted less-invasive surfactant administration quality improvement initiative

    by Dalibor Kurepa, Vitaliya Boyar, Olena Predtechenska, Venkata Gupta, Barry Weinberger, Margaret Pulju, Alla Zaytseva, Stephanie G Galanti, Gangajal Kasniya, Shahana Perveen

    Objective To describe the use of quality improvement methodology in transitioning from delivery of surfactant by INSURE (INtubation–SURfactant administration–Extubation) to video laryngoscope-assisted LISA (less-invasive surfactant administration) for infants with respiratory distress syndrome (RDS) receiving non-invasive ventilatory support. Setting Two large neonatal intensive care units (NICUs) at Northwell Health (New Hyde Park, New York, USA). Study population Infants with RDS receiving continuous positive airway pressure in the NICU and eligible for surfactant administration. Results LISA was initiated in our NICUs in January 2021, after extensive guideline development, education programmes, hands-on training and provider credentialing. Our Specific, Measurable, Achievable, Relevant and Timely aim was to deliver surfactant by LISA for 65% of total doses by 31 December 2021. This goal was achieved within 1 month of go-live. In total, 115 infants received at least one dose of surfactant during the year. Of those, 79 (69%) received it via LISA and 36 (31%) via INSURE. Two Plan–Do–Study–Act cycles contributed to improved adherence to guidelines on timely surfactant administration and both written and video documentation. Conclusions Safe and effective introduction of LISA with the use of video laryngoscopy is achievable with careful planning, clear clinical guidelines, adequate hands-on training and comprehensive safety and quality control.


  • Lung ultrasound assessment of pulmonary edema in neonates with chronic lung disease before and after diuretic therapy

    by Gangajal Kasniya, Barry Weinberger, Jane Cerise, Margaret Pulju, Vitaliya Boyar, Florin Frunza, Dalibor Kurepa

    Introduction: Bronchopulmonary dysplasia (BPD) is characterized by lung injury with varying degrees of disrupted alveolarization, vascular remodeling, inflammatory cell proliferation, and pulmonary edema. Diuretics are often used to ameliorate the symptoms or progression of BPD. Our primary objective was to use lung ultrasound (LUS) to determine if diuretics decrease pulmonary edema in infants with BPD. The secondary objective was to assess changes in respiratory support during the first week after initiation of diuretics.Methods: Premature infants requiring noninvasive respiratory support and starting diuretic therapy for evolving BPD were compared with a similar group of infants not receiving diuretics (control). For the diuretic group, LUS exams were performed before and on Days 1, 3, and 6 after initiation of treatment. For the control group, LUS was performed at equivalent time points. A composite pulmonary edema severity (PES) score of 0–5 was calculated based on the total number of B‐lines in six scanned areas. Respiratory support parameters (FiO2, nasal cannula flow, or CPAP) were also recorded.Results: Infants in the diuretic (n = 28) and control (n = 23) groups were recruited at median corrected gestational ages of 34.2 (33.3–35.9) and 34.0 (33.4–36.3) weeks, respectively (p = 0.82). PES scores, FiO2, and respiratory flow support decreased significantly from Days 0 to 6 (p < 0.0001, p = 0.001, and p = 0.01, respectively) in the diuretic group, but not in the control group.Conclusion: Diuretic use is associated with decreased pulmonary edema and improved oxygenation in infants with BPD during the first week of treatment.


  • Open Access

    Lung Ultrasound Assessment of Pulmonary Edema in Neonates with Chronic Lung Disease Before and After Diuretic Therapy

    by Dalibor Kurepa, Gangajal Kasniya, Jane Cerise, Margaret Pulju, Vitaliya Boyar, Florin Frunza, Barry Weinberger

    Introduction: Bronchopulmonary dysplasia (BPD) is characterized by lung injury with varying degrees of disrupted alveolarization, vascular remodeling, inflammatory cell proliferation, and pulmonary edema. Diuretics are often used to ameliorate the symptoms or progression of BPD. Our primary objective was to use lung ultrasound (LUS) to determine if diuretics decrease pulmonary edema in infants with BPD. The secondary objective was to assess changes in respiratory support during the first week after initiation of diuretics. Methods: Premature infants requiring non-invasive respiratory support and starting diuretic therapy for evolving BPD were compared with a similar group of infants not receiving diuretics (control). For the diuretic group, LUS exams were performed before and on days 1, 3 and 6 after initiation of treatment. For the control group, LUS was performed at equivalent time points. A composite pulmonary edema severity (PES) score of 0 to 5 was calculated based on the total number of B-lines in 6 scanned areas. Respiratory support parameters (FiO2, nasal cannula flow or CPAP) were also recorded. Results : Infants in the diuretic (n=28) and control (n=23) groups were recruited at median corrected gestational ages of 34.2 (33.3-35.9) and 34.0 (33.4-36.3) weeks, respectively ( p =0.82). PES scores, FiO2, and respiratory flow support decreased significantly from day 0 to 6 ( p <.0001, p =0.001, and p=0.01, respectively) in the diuretic group, but not in the control group. Conclusion: Diuretic use is associated with decreased pulmonary edema and improved oxygenation in infants with BPD during the first week of treatment.

  • Correlation between visual inspection/physical exam and point-of-care ultrasound exam in the evaluation of neonatal peripheral intravenous catheter site

    by Ioan-Florinel Frunza, Vitaliya Boyar, Joanna Fishbein, Dalibor Kurepa

    A peripheral intravenous catheter (PIVC) is used to administer IV fluids and medications. The most common PIVC complication is peripheral intravenous extravasation and infiltration (PIVE/I). Early ...


  • Ultrasound Assessment of Gastric Emptying in Premature Infants Treated With Non‐Invasive Ventilatory Support

    by Arkar Ye Hlaing, Barry Weinberger, Richard Schanler, Jane Cerise, Dalibor Kurepa

    Background: Nasal continuous positive airway pressure (CPAP) introduces positive pressure of air into both the trachea and stomach, which may affect gastric emptying. The rate of gastric emptying can be estimated by ultrasound (US) in neonates by two validated techniques: “antral cross‐sectional area” (ACSA, two‐dimensional estimate of the surface area at the gastric antrum), and “spheroid gastric volume” (spheroid, three‐dimensional estimate of the stomach volume).Objective: To compare gastric emptying rates in neonates on machine‐derived nasal CPAP (MD‐nCPAP, Avea and RAM cannula) with those on bubble CPAP (bCPAP, Fisher Paykel and Babi.Plus nasal prongs).Methods: Ultrasound measurements of the amount of the milk in the stomach were performed before feeding and at 1, 2, and 3 hours after the start of feeding, using both the ACSA and spheroid methods. Rates of gastric emptying were calculated during the “early” (1–2 hours) and “late” (2–3 hours) phases after feeding.Results: We recruited 32 infants (25–34 weeks gestational age, full enteral tube feedings, on nasal CPAP). Seventeen infants were treated with MD‐nCPAP (median birth weight 1015 g [interquartile range (IQR): 870–1300], gestational age 28 weeks [IQR: 27–29], postnatal age 20 days [IQR: 14–28]), whereas 15 infants were treated with bCPAP (median birth weight 960 g [IQR: 855–1070], gestational age 27 weeks [IQR: 26–28], postnatal age 17 days [IQR: 15–25]). Gastric emptying rates (% emptied/min) were significantly faster in the “early” compared to the “late” phase for all infants. There were no significant differences in the rates of gastric emptying (either “early” or “late”) or volumes of gastric residuals between infants receiving MD‐nCPAP or bCPAP, measured by either method. Although no feeding intolerance was seen in either group, the volumes of residual gastric contents measured by both methods were higher than the volumes traditionally considered abnormal when obtained by gastric tube aspiration.Conclusions: Gastric emptying is faster during the “early” compared to the “late” phase. Gastric emptying rates are not different in infants receiving MD‐nCPAP versus bCPAP. The presence of large residual gastric contents in infants who are tolerating feedings challenges the value of traditional gastric aspiration for the assessment of feeding tolerance in infants.


  • Open Access

    Ultrasound assessment of gastric emptying in premature infants treated with non-invasive ventilatory support

    by Dalibor Kurepa, Richard Schanler, Barry Weinberger, Arkar Ye Hlaing

    Background: Nasal CPAP introduces positive pressure of air into both trachea and stomach, which may affect gastric emptying. The rate of gastric emptying can be estimated by US by two validated techniques: “antral cross-sectional area” (2-dimensional estimate of the surface area at the gastric antrum), and “spheroid gastric volume” (3-dimensional estimate of the stomach content volume). No study examined gastric emptying rate in infants on bubble CPAP (bCPAP). Objective: To compare gastric emptying rates in neonates on machine-derived nasal CPAP (MD-nCPAP) with those on bCPAP. Methods: Ultrasound measurements of the amount of milk in the stomach were performed before feeding and at 1, 2, and 3 hours after the start of feeding, using both the ACSA and spheroid methods. Rates of gastric emptying were calculated during the “early” (1-2 hours) and “late” (2-3 hours) phases after feeding. Results: We recruited 32 infants (25-34 weeks gestational age). Seventeen infants were treated with MD-nCPAP [median birth weight 1015 g (IQR: 870 to 1300), gestational age 28 weeks (IQR: 27 to 29), postnatal age 20 days (IQR: 14 to 28)], while 15 infants were treated with bCPAP [median birth weight 960 g (IQR: 855 to 1070), gestational age 27 weeks (IQR: 26 to 28), postnatal age 17 days (IQR: 15 to 25)]. Gastric emptying rates (% emptied/min) were significantly faster in the “early” compared to the “late” phase for all infants. There were no significant differences in the rates of gastric emptying (either “early” or “late”) or volumes of gastric residuals between infants receiving MD-nCPAP or bCPAP, measured by either method. Conclusions: Gastric emptying is faster during the “early” compared to the “late” phase. Gastric emptying rates are not different in infants receiving MD-nCPAP vs bCPAP.