Impact of bubble size in a rat model of cerebral air microembolization
Authors:
- Martin JuenemannMJMartin Juenemann
- Mesut YeniguenMYMesut Yeniguen
- Nadine SchleicherNSNadine Schleicher
- Johannes BlumensteinJBJohannes Blumenstein
- Max NedelmannMNMax Nedelmann
- Marlene TschernatschMTMarlene Tschernatsch
- Georg BachmannGBGeorg Bachmann
- Manfred KapsMKManfred Kaps
- Petr UrbanekPUPetr Urbanek
- Markus SchoenburgMSMarkus Schoenburg
- Tibo GerrietsTGTibo Gerriets
Open Access
- 18 October 2013
- journal article
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 8 (1) , 198
Abstract
Background: Cerebral air microembolization (CAM) is a frequent side effect of diagnostic or therapeutic interventions. Besides reduction of the amount of bubbles, filter systems in the clinical setting may also lead to a dispersion of large gas bubbles and therefore to an increase of the gas–liquid-endothelium interface. We evaluated the production and application of different strictly defined bubble diameters in a rat model of CAM and assessed functional outcome and infarct volumes in relation to the bubble diameter. Methods: Gas emboli of defined number and diameter were injected into the carotid artery of rats. Group I (n = 7) received 1800 air bubbles with a diameter of 45 μm, group II (n = 7) 40 bubbles of 160 μm, controls (n = 6) saline without gas bubbles; group I and II yielded the same total injection volume of air with 86 nl. Functional outcome was assessed at baseline, after 4 h and 24 h following cerebral MR imaging and infarct size calculation. Results: Computer-aided evaluation of bubble diameters showed high constancy (group I: 45.83 μm ± 2.79; group II: 159 μm ± 1.26). Animals in group I and II suffered cerebral ischemia and clinical deterioration without significant difference. Infarct sizes did not differ significantly between the two groups (p = 0.931 u-test). Conclusions: We present further development of a new method, which allows reliable and controlled CAM with different bubble diameters, producing neurological deficits due to unilateral cerebral damage. Our findings could not display a strong dependency of stroke frequency and severity on bubble diameter.Keywords
This publication has 36 references indexed in Scilit:
- The effect of blood pressure on cerebral outcome in a rat model of cerebral air embolism during cardiopulmonary bypassThe Journal of Thoracic and Cardiovascular Surgery, 2011
- A rat model for cerebral air microembolisationJournal of Neuroscience Methods, 2010
- Microemboli may link spreading depression, migraine aura, and patent foramen ovaleAnnals of Neurology, 2009
- Protecting the brain from gaseous and solid micro-emboli during coronary artery bypass grafting: a randomized controlled trialEuropean Heart Journal, 2009
- Cerebral Air Emboli Differentially Alter Outcome after Cardiopulmonary Bypass in Rats Compared with Normal CirculationAnesthesiology, 2007
- Reduction in Air Bubble Size Using Perfluorocarbons During Cardiopulmonary Bypass in the RatAnesthesia & Analgesia, 2006
- Clinically Silent Cerebral Ischemic Events After Cardiac Surgery: Their Incidence, Regional Vascular Occurrence, and Procedural DependenceThe Annals of Thoracic Surgery, 2006
- Capture of particulate emboli during cardiac procedures in which aortic cross-clamp is usedThe Annals of Thoracic Surgery, 2000
- The effect of gas emboli on rabbit cerebral blood flow.Stroke, 1990
- Experimental air embolism of the brain: an analysis of the technique in the rat.Stroke, 1982