Nadine Schleicher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nadine Schleicher has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Georg Bachmann
Department of Radiology, Kerckhoff Clinic, Bad Nauheim, Germany
1 shared publication - Johannes Blumenstein
Department of Cardiac Surgery, Kerckhoff-Klinik, Heart Center, Bad Nauheim, Germany
1 shared publication - Manfred Kaps
Klinik und Poliklinik für Neurologie, Universitätsklinikum Giessen, Giessen
1 shared publication - Markus Schönburg
Department of Cardiac Surgery, Kerckhoff Heart Center, Benekestr. 2-8, 61231 Bad Nauheim, Germany
1 shared publication - Marlene Tschernatsch
Department of Neurology, University Hospital of the Justus-Liebig-University Giessen, Klinikstrasse 33, 35392 Giessen, Germany
1 shared publication - Martin Juenemann
Department of Neurology, Justus Liebig University, Giessen, Germany
1 shared publication
Latest Publications
- Open Access
- 18 October 2013
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 8 (1) , 198
Impact of bubble size in a rat model of cerebral air microembolization
Background: Cerebral air microembolization (CAM) is a frequent side effect of diagnostic or therapeutic interventions. Besides reduction of the amount of bubbles, filter systems in the clinical setting may also lead to a dispersion of large gas bubbles and therefore to an increase of the gas–liquid-endothelium interface. We evaluated the production and application of different strictly defined bubble diameters in a rat model of CAM and assessed functional outcome and infarct volumes in relation to the bubble diameter. Methods: Gas emboli of defined number and diameter were injected into the carotid artery of rats. Group I (n = 7) received 1800 air bubbles with a diameter of 45 μm, group II (n = 7) 40 bubbles of 160 μm, controls (n = 6) saline without gas bubbles; group I and II yielded the same total injection volume of air with 86 nl. Functional outcome was assessed at baseline, after 4 h and 24 h following cerebral MR imaging and infarct size calculation. Results: Computer-aided evaluation of bubble diameters showed high constancy (group I: 45.83 μm ± 2.79; group II: 159 μm ± 1.26). Animals in group I and II suffered cerebral ischemia and clinical deterioration without significant difference. Infarct sizes did not differ significantly between the two groups (p = 0.931 u-test). Conclusions: We present further development of a new method, which allows reliable and controlled CAM with different bubble diameters, producing neurological deficits due to unilateral cerebral damage. Our findings could not display a strong dependency of stroke frequency and severity on bubble diameter.
- 18 October 2013
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 8 (1) , 198
Open AccessImpact of bubble size in a rat model of cerebral air microembolization
Background: Cerebral air microembolization (CAM) is a frequent side effect of diagnostic or therapeutic interventions. Besides reduction of the amount of bubbles, filter systems in the clinical setting may also lead to a dispersion of large gas bubbles and therefore to an increase of the gas–liquid-endothelium interface. We evaluated the production and application of different strictly defined bubble diameters in a rat model of CAM and assessed functional outcome and infarct volumes in relation to the bubble diameter. Methods: Gas emboli of defined number and diameter were injected into the carotid artery of rats. Group I (n = 7) received 1800 air bubbles with a diameter of 45 μm, group II (n = 7) 40 bubbles of 160 μm, controls (n = 6) saline without gas bubbles; group I and II yielded the same total injection volume of air with 86 nl. Functional outcome was assessed at baseline, after 4 h and 24 h following cerebral MR imaging and infarct size calculation. Results: Computer-aided evaluation of bubble diameters showed high constancy (group I: 45.83 μm ± 2.79; group II: 159 μm ± 1.26). Animals in group I and II suffered cerebral ischemia and clinical deterioration without significant difference. Infarct sizes did not differ significantly between the two groups (p = 0.931 u-test). Conclusions: We present further development of a new method, which allows reliable and controlled CAM with different bubble diameters, producing neurological deficits due to unilateral cerebral damage. Our findings could not display a strong dependency of stroke frequency and severity on bubble diameter.