Measuring the Internal Stress in Ovine Meniscus During Simulated In Vivo Gait Kinematics: A Novel Method Using Fibre Optic Technology
Authors:
- 22 October 2020
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (4) , 1199-1208
Abstract
Changes in stress transferred across articular joints have been described as a substantial factor in the initiation and progression of joint disease such as post-traumatic osteoarthritis and have thus been of interest to biomechanical researchers. However, to date, stress magnitudes within the menisci have not been successfully measured. In this study, a novel method for measuring stress within the menisci is presented. Small Fibre Bragg Grating (FBG) sensors were inserted inside menisci and used to measure mechanical stress during replicated gait cycles. In-vitro stress measurements within the menisci were preformed for healthy gait and gait following surgical damage to the joints. Together with our capability to reproduce in vivo motions accurately, the improvements in fibre optic technology have allowed for the first direct measurement of mechanical stress in menisci.Keywords
Funding Information
- Canadian Institute of Health Research
- Natural Sciences and Engineering Research Council of Canada
This publication has 37 references indexed in Scilit:
- Patellofemoral contact patterns before and after total knee arthroplasty: an in vitro measurementBioMedical Engineering OnLine, 2013
- Technical Issues in Using Robots to Reproduce Joint Specific GaitJournal of Biomechanical Engineering, 2011
- Design of a Pressure Sensor Based on Optical Fiber Bragg Grating Lateral DeformationSensors, 2010
- An in-fiber Bragg grating sensor for contact force and stress measurements in articular jointsMeasurement Science and Technology, 2010
- A minimally invasive in-fiber Bragg grating sensor for intervertebral disc pressure measurementsMeasurement Science and Technology, 2008
- A simple temperature-insensitive fiber Bragg grating displacement sensorOptics Communications, 2007
- Fibre optic Bragg grating sensors: An alternative method to strain gauges for measuring deformation in boneMedical Engineering & Physics, 2007
- Meniscal tears: The effect of meniscectomy and of repair on intraarticular contact areas and stress in the human kneeThe American Journal of Sports Medicine, 1986
- Transmission of the Load in the Knee Joint with Special Reference to the Role of the MenisciEngineering in Medicine, 1979
- The Role of the Menisci in Force Transmission Across the KneeClinical Orthopaedics and Related Research, 1975