Paris Vakiel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paris Vakiel has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Christopher R. Dennison
Department of Mechanical Engineering, University of Victoria, Victoria, Canada
5 shared publications - Donald Raboud
Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
5 shared publications - Kevin Adanty
Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
5 shared publications - Simon Ouellet
Weapons Effects and Protection Section, Defence R&D Valcartier Research Center, Quebec, Canada
5 shared publications - Yizhao Li
School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
5 shared publications - Albert H. Vette
Department of Mechanical Engineering, University of Alberta, Donadeo Innovation Centre for Engineering, Edmonton, Alberta, T6G 1H9, Canada; Department of Biomedical Engineering, University of Alberta, Donadeo Innovation Centre for Engineering, Edmonton, Alberta, T6G 1H9, Canada; Glenrose Rehabilitation Hospital, Alberta Health Services, 10230-111 Avenue, NW, Edmonton, Alberta, T5G 0B7, Canada
4 shared publications
Latest Publications
- Open Access
- 2 November 2023
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (3) , 734
Correction: Evaluating the Intracranial Pressure Biofidelity and Response Repeatability of a Physical Head-Brain Model in Frontal Impacts
- 2 November 2023
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (3) , 734
Open AccessCorrection: Evaluating the Intracranial Pressure Biofidelity and Response Repeatability of a Physical Head-Brain Model in Frontal Impacts
- Open Access
- 29 May 2023
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 51 (8) , 1834
Publisher Correction: Evaluating the Intracranial Pressure Biofidelity and Response Repeatability of a Physical Head-Brain Model in Frontal Impacts
- 29 May 2023
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 51 (8) , 1834
Open AccessPublisher Correction: Evaluating the Intracranial Pressure Biofidelity and Response Repeatability of a Physical Head-Brain Model in Frontal Impacts
- 24 April 2023
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 51 (8) , 1816-1833
Evaluating the Intracranial Pressure Biofidelity and Response Repeatability of a Physical Head-Brain Model in Frontal Impacts
Headforms are widely used in head injury research and headgear assessment. Common headforms are limited to replicating global head kinematics, although intracranial responses are crucial to understanding brain injuries. This study aimed to evaluate the biofidelity of intracranial pressure (ICP) and the repeatability of head kinematics and ICP of an advanced headform subjected to frontal impacts. Pendulum impacts were performed on the headform using various impact velocities (1–5 m/s) and impactor surfaces (vinyl nitrile 600 foam, PCM746 urethane, and steel) to simulate a previous cadaveric experiment. Head linear accelerations and angular rates in three axes, cerebrospinal fluid ICP (CSFP), and intraparenchymal ICP (IPP) at the front, side, and back of the head were measured. The head kinematics, CSFP, and IPP demonstrated acceptable repeatability with coefficients of variation generally being less than 10%. The BIPED front CSFP peaks and back negative peaks were within the range of the scaled cadaver data (between the minimum and maximum values reported by Nahum et al.), while side CSFPs were 30.9–92.1% greater than the cadaver data. CORrelation and Analysis (CORA) ratings evaluating the closeness of two time histories demonstrated good biofidelity of the front CSFP (0.68–0.72), while the ratings for the side (0.44–0.70) and back CSFP (0.27–0.66) showed a large variation. The BIPED CSFP at each side was linearly related to head linear accelerations with coefficients of determination greater than 0.96. The slopes for the BIPED front and back CSFP-acceleration linear trendlines were not significantly different from cadaver data, whereas the slope for the side CSFP was significantly greater than cadaver data. This study informs future applications and improvements of a novel head surrogate.
- 24 April 2023
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 51 (8) , 1816-1833
Evaluating the Intracranial Pressure Biofidelity and Response Repeatability of a Physical Head-Brain Model in Frontal Impacts
Headforms are widely used in head injury research and headgear assessment. Common headforms are limited to replicating global head kinematics, although intracranial responses are crucial to understanding brain injuries. This study aimed to evaluate the biofidelity of intracranial pressure (ICP) and the repeatability of head kinematics and ICP of an advanced headform subjected to frontal impacts. Pendulum impacts were performed on the headform using various impact velocities (1–5 m/s) and impactor surfaces (vinyl nitrile 600 foam, PCM746 urethane, and steel) to simulate a previous cadaveric experiment. Head linear accelerations and angular rates in three axes, cerebrospinal fluid ICP (CSFP), and intraparenchymal ICP (IPP) at the front, side, and back of the head were measured. The head kinematics, CSFP, and IPP demonstrated acceptable repeatability with coefficients of variation generally being less than 10%. The BIPED front CSFP peaks and back negative peaks were within the range of the scaled cadaver data (between the minimum and maximum values reported by Nahum et al.), while side CSFPs were 30.9–92.1% greater than the cadaver data. CORrelation and Analysis (CORA) ratings evaluating the closeness of two time histories demonstrated good biofidelity of the front CSFP (0.68–0.72), while the ratings for the side (0.44–0.70) and back CSFP (0.27–0.66) showed a large variation. The BIPED CSFP at each side was linearly related to head linear accelerations with coefficients of determination greater than 0.96. The slopes for the BIPED front and back CSFP-acceleration linear trendlines were not significantly different from cadaver data, whereas the slope for the side CSFP was significantly greater than cadaver data. This study informs future applications and improvements of a novel head surrogate.
- 19 September 2022
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 145 (1)
Review of Mechanisms and Research Methods for Blunt Ballistic Head Injury
Head injuries account for 15%–20% of all military injuries and pose a high risk of causing functional disability and fatality. Blunt ballistic impacts are one of the threats that can lead to severe head injuries. This review aims to examine the mechanisms and injury risk assessment associated with blunt ballistic head injury (BBHI). The review further discusses research methods and instrumentation used in BBHI studies, focusing on their limitations and challenges. Studies on the mechanisms of focal and diffuse brain injuries remain largely inconclusive and require further effort. Some studies have attempted to associate BBHIs with head mechanics, but more research is required to establish correlations between head mechanics and injury severity. Limited access to experimental models and a lack of instrumentation capable of measuring the mechanics of brain tissue in situ are potential reasons for the lack of understanding of injury mechanisms, injury correlations, and injury tolerance levels specific to this loading regime. Targeted research for understanding and assessing head injuries in blunt ballistic impacts is a necessary step in improving our ability to design protection systems to mitigate these injuries.
- 19 September 2022
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 145 (1)
Review of Mechanisms and Research Methods for Blunt Ballistic Head Injury
Head injuries account for 15%–20% of all military injuries and pose a high risk of causing functional disability and fatality. Blunt ballistic impacts are one of the threats that can lead to severe head injuries. This review aims to examine the mechanisms and injury risk assessment associated with blunt ballistic head injury (BBHI). The review further discusses research methods and instrumentation used in BBHI studies, focusing on their limitations and challenges. Studies on the mechanisms of focal and diffuse brain injuries remain largely inconclusive and require further effort. Some studies have attempted to associate BBHIs with head mechanics, but more research is required to establish correlations between head mechanics and injury severity. Limited access to experimental models and a lack of instrumentation capable of measuring the mechanics of brain tissue in situ are potential reasons for the lack of understanding of injury mechanisms, injury correlations, and injury tolerance levels specific to this loading regime. Targeted research for understanding and assessing head injuries in blunt ballistic impacts is a necessary step in improving our ability to design protection systems to mitigate these injuries.
- 4 February 2021
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (4) , 1268-1269
Correction to: Mapping Stresses on the Tibial Plateau Cartilage in an Ovine Model Using In-Vivo Gait Kinematics
- 4 February 2021
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (4) , 1268-1269
Correction to: Mapping Stresses on the Tibial Plateau Cartilage in an Ovine Model Using In-Vivo Gait Kinematics
- 22 October 2020
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (4) , 1199-1208
Measuring the Internal Stress in Ovine Meniscus During Simulated In Vivo Gait Kinematics: A Novel Method Using Fibre Optic Technology
Changes in stress transferred across articular joints have been described as a substantial factor in the initiation and progression of joint disease such as post-traumatic osteoarthritis and have thus been of interest to biomechanical researchers. However, to date, stress magnitudes within the menisci have not been successfully measured. In this study, a novel method for measuring stress within the menisci is presented. Small Fibre Bragg Grating (FBG) sensors were inserted inside menisci and used to measure mechanical stress during replicated gait cycles. In-vitro stress measurements within the menisci were preformed for healthy gait and gait following surgical damage to the joints. Together with our capability to reproduce in vivo motions accurately, the improvements in fibre optic technology have allowed for the first direct measurement of mechanical stress in menisci.
- 22 October 2020
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (4) , 1199-1208
Measuring the Internal Stress in Ovine Meniscus During Simulated In Vivo Gait Kinematics: A Novel Method Using Fibre Optic Technology
Changes in stress transferred across articular joints have been described as a substantial factor in the initiation and progression of joint disease such as post-traumatic osteoarthritis and have thus been of interest to biomechanical researchers. However, to date, stress magnitudes within the menisci have not been successfully measured. In this study, a novel method for measuring stress within the menisci is presented. Small Fibre Bragg Grating (FBG) sensors were inserted inside menisci and used to measure mechanical stress during replicated gait cycles. In-vitro stress measurements within the menisci were preformed for healthy gait and gait following surgical damage to the joints. Together with our capability to reproduce in vivo motions accurately, the improvements in fibre optic technology have allowed for the first direct measurement of mechanical stress in menisci.
- 22 October 2020
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (5) , 1288-1297
Mapping Stresses on the Tibial Plateau Cartilage in an Ovine Model Using In-Vivo Gait Kinematics
Understanding stresses within the knee joint is central to understanding knee function, and the etiology and progression of degenerative joint diseases such as post-traumatic osteoarthritis. In this study, in vivo gait kinematics of four ovine subjects were recorded using a highly accurate Instrumented Spatial Linkage (ISL) as each subject walked on a standard treadmill. The subjects were then sacrificed, and the right hind limbs removed. Ten purpose-built Fibre Bragg Grating (FBG) sensors were positioned within each stifle joint and used to measured contact stresses on the articulating surface of the tibial plateau as the recorded gait was replicated using a 6-degrees-of-freedom parallel robotic system. This study provides the first accurate, direct measurement of stress in a joint during in vivo gait replication. It was hypothesized that the results would indicate a direct link between gait kinematics and measured stress values. Contrary to this expectation no direct link was found between individualistic differences in kinematics and differences in stress magnitudes. This finding highlights the complex multifactorial nature of stress magnitudes and distribution patterns across articular joints. The results also indicate that stress magnitudes within the knee joint are highly position dependent with magnitudes varying substantially between points only a few mm apart.
- 22 October 2020
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (5) , 1288-1297
Mapping Stresses on the Tibial Plateau Cartilage in an Ovine Model Using In-Vivo Gait Kinematics
Understanding stresses within the knee joint is central to understanding knee function, and the etiology and progression of degenerative joint diseases such as post-traumatic osteoarthritis. In this study, in vivo gait kinematics of four ovine subjects were recorded using a highly accurate Instrumented Spatial Linkage (ISL) as each subject walked on a standard treadmill. The subjects were then sacrificed, and the right hind limbs removed. Ten purpose-built Fibre Bragg Grating (FBG) sensors were positioned within each stifle joint and used to measured contact stresses on the articulating surface of the tibial plateau as the recorded gait was replicated using a 6-degrees-of-freedom parallel robotic system. This study provides the first accurate, direct measurement of stress in a joint during in vivo gait replication. It was hypothesized that the results would indicate a direct link between gait kinematics and measured stress values. Contrary to this expectation no direct link was found between individualistic differences in kinematics and differences in stress magnitudes. This finding highlights the complex multifactorial nature of stress magnitudes and distribution patterns across articular joints. The results also indicate that stress magnitudes within the knee joint are highly position dependent with magnitudes varying substantially between points only a few mm apart.
- Open Access
- 17 October 2020
- Published by Elsevier in Osteoarthritis and Cartilage Open
- Vol. 2 (4) , 100109
Correlation of damage score in PTOA with changes in stress on cartilage in an ovine model
- 17 October 2020
- Published by Elsevier in Osteoarthritis and Cartilage Open
- Vol. 2 (4) , 100109
Open AccessCorrelation of damage score in PTOA with changes in stress on cartilage in an ovine model