Effect of Plasma Treatment on the Sensor Properties of a Light‐Addressable Potentiometric Sensor (LAPS)
Open Access
- 18 July 2019
- journal article
- research article
- Published by Wiley in Physica Status Solidi (a)
- Vol. 216 (20) , 1900259
Abstract
A light‐addressable potentiometric sensor (LAPS) is a field‐effect‐based (bio‐) chemical sensor, in which a desired sensing area on the sensor surface can be defined by illumination. Light addressability can be used to visualize the concentration and spatial distribution of the target molecules, e.g., H+ ions. This unique feature has great potential for the label‐free imaging of the metabolic activity of living organisms. The cultivation of those organisms needs specially tailored surface properties of the sensor. O2 plasma treatment is an attractive and promising tool for rapid surface engineering. However, the potential impacts of the technique are carefully investigated for the sensors that suffer from plasma‐induced damage. Herein, a LAPS with a Ta2O5 pH‐sensitive surface is successfully patterned by plasma treatment, and its effects are investigated by contact angle and scanning LAPS measurements. The plasma duration of 30 s (30 W) is found to be the threshold value, where excessive wettability begins. Furthermore, this treatment approach causes moderate plasma‐induced damage, which can be reduced by thermal annealing (10 min at 300 °C). These findings provide a useful guideline to support future studies, where the LAPS surface is desired to be more hydrophilic by O2 plasma treatment.Keywords
This publication has 29 references indexed in Scilit:
- Retracted: Study of the wettability of ZnO nanofilmsInternational Nano Letters, 2012
- Plasma and vacuum ultraviolet induced charging of SiO2 and HfO2 patterned structuresJournal of Vacuum Science & Technology A, 2011
- Oxygen plasma-treated gold nanoparticle-based field-effect devices as transducer structures for bio-chemical sensingMicrochimica Acta, 2008
- “LAPS Card”—A novel chip card-based light-addressable potentiometric sensor (LAPS)Sensors and Actuators B: Chemical, 2006
- Development of a handheld 16 channel pen-type LAPS for electrochemical sensingSensors and Actuators B: Chemical, 2005
- High resolution LAPS using amorphous silicon as the semiconductor materialSensors and Actuators B: Chemical, 2004
- Chemical imaging sensor and its application to biological systemsElectrochimica Acta, 2001
- Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS?Sensors and Actuators B: Chemical, 2001
- Characteristics of silicon nitride after O/sub 2/ plasma surface treatment for pH-ISFET applicationsIEEE Transactions on Biomedical Engineering, 2001
- The effect of O2 plasma on properties of the Si-SiO2 systemPhysica Status Solidi (a), 1980