Open Proximal Rectus Femoris Tendon Full‐Thickness Tear Repair With Double‐Row Suture Anchor Transosseous‐Equivalent Construct With Biologic Augmentation Using Bone Marrow Aspirate Concentrate and Bovine Bioinductive Collagen Implant
Open Access
- 31 August 2026
- journal article
- research article
- Published by Wiley in Arthroscopy Techniques
- Vol. 15 (9) , e70247
Abstract
Proximal full‐thickness rectus femoris tendon tears are debilitating injuries in high‐demand athletes, particularly those involved in sprinting and soccer. Although direct repair remains the mainstay of treatment, concerns exist regarding tendon healing, strength restoration, and the risk of retear. Contemporary suture anchor fixation techniques employing a double‐row transosseous‐equivalent construct, combined with biologic augmentation with autologous bone marrow aspirate concentrate and a highly purified type I bioinductive collagen implant, offer a potential means to increase the tendon‐bone contact area and reinforce the repair construct. We describe our preferred open technique using a double‐row transosseous‐equivalent construct to maximize tendon footprint coverage and compression, combined with bone marrow aspirate concentrate and bioinductive collagen implant to enhance tendon‐to‐bone healing biology.Keywords
This publication has 27 references indexed in Scilit:
- Centrifuge‐Free Bone Marrow Aspirate Harvest for Orthopaedic ApplicationsArthroscopy Techniques, 2025
- Bone Marrow Aspirate Concentrate Harvest Techniques for the Sports Medicine SurgeonArthroscopy Techniques, 2024
- Should proximal ruptures of the anterior rectus femoris muscle be treated surgically?Chinese Journal of Traumatology, 2021
- “Current concepts and expert practice report: Augmentation of rotator cuff repairs”Journal of Clinical Orthopaedics and Trauma, 2021
- Bicortical Titanium Tenodesis Button With Double‐Row Fixation for the Treatment of Proximal Rectus Femoris Avulsion: Review of Literature and Surgical TechniqueArthroscopy Techniques, 2021
- Double‐Row Suture Anchor Repair of Posterolateral Corner Avulsion FracturesArthroscopy Techniques, 2017
- Biologic augmentation of rotator cuff repair with mesenchymal stem cells during arthroscopy improves healing and prevents further tears: a case-controlled studyInternational Orthopaedics, 2014
- Scaffold devices for rotator cuff repairJournal of Shoulder and Elbow Surgery, 2012
- Biomechanical Advantages of Triple‐Loaded Suture Anchors Compared With Double‐Row Rotator Cuff RepairsArthroscopy, 2009
- Total proximal tendon avulsion of the rectus femoris muscleScandinavian Journal of Medicine & Science in Sports, 2006