Pathology-based radiation dose in computed tomography: investigation of the effect of lung lesions on water-equivalent diameter, CTDIVol and SSDE in COVID-19 patients
- 9 September 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (19) , 2356-2365
Abstract
Lung lesions can increase the CT number and affect the water-equivalent diameter (Dw), Dw-based conversion factor (CFw), and Dw-based size-specific dose estimate (SSDEw). We evaluated the effect of COVID-19 lesions and total severity score (TSS) on radiation dose considering the effect of automatic tube current modulation (ATCM) and fixed tube current (FTC). A total of 186 chest CT scans were categorised into five TSS groups, including healthy, minimal, mild, moderate and severe. The effective diameter (Deff), Dw, CFw, Deff-based conversion factor (CFeff), volume computed tomography dose index (CTDIVol), pathological dose impact factor (PDIF) 1 and SSDEw were calculated. TSS was correlated with Dw (r = 0.29, p-value = 0.001), CTDIVol (ATCM) (r = 0.23, p = 0.001) and PDIF (r = − 0.51, p-value = 0.001). $\overline{{\mathrm{SSDE}}_{\mathrm{w}}}$ (FTC) was significantly different among all groups. $\overline{{\mathrm{SSDE}}_{\mathrm{w}}}$ (ATCM) was greater for moderate (13%) and mild (14%) groups. Increasing TSS increase the Dw and causes a decrease in CFw and $\overline{{\mathrm{SSDE}}_{\mathrm{w}}}$ (FTC), and can increase $\overline{{\mathrm{SSDE}}_{\mathrm{w}}}$ (ATCM) in some Dw ranges.
Keywords
Funding Information
- Research Council of Aja University of Medical Sciences (97001884)
This publication has 35 references indexed in Scilit:
- CT images and radiotherapy treatment planning of patients with breast cancer: A datasetData in Brief, 2017
- Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective doseEuropean Journal of Radiology, 2016
- Attenuation‐based size metric for estimating organ dose to patients undergoing tube current modulated CT examsMedical Physics, 2015
- Size‐specific, scanner‐independent organ dose estimates in contiguous axial and helical head CT examinationsMedical Physics, 2014
- Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image qualityEuropean Radiology, 2014
- MO‐E‐17A‐01: BEST IN PHYSICS (IMAGING) – Calculating SSDE From CT Exams Using Size Data Available in the DICOM Header of CT Localizer RadiographsMedical Physics, 2014
- Dose in x-ray computed tomographyPhysics in Medicine & Biology, 2014
- Relationships between patient size, dose and image noise under automatic tube current modulation systemsJournal of Radiological Protection, 2013
- Assessment of patient dose from CT localizer radiographsMedical Physics, 2013
- NCRP REPORT NO. 160, IONIZING RADIATION EXPOSURE OF THE POPULATION OF THE UNITED STATES, MEDICAL EXPOSURE—ARE WE DOING LESS WITH MORE, AND IS THERE A ROLE FOR HEALTH PHYSICISTS?Health Physics, 2009