HEHojat Ebrahiminik

Hojat Ebrahiminik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hojat Ebrahiminik has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diagnostic yield of fine needle aspiration with simultaneous core needle biopsy for thyroid nodules

    by Mohammad Ali Hasannia, Ramin Pourghorban, Hoda Asefi, Amir Aria, Elham Nazar, Hojat Ebrahiminik, Alireza Mohamadian

    Background: Fine needle aspiration (FNA) is a widely utilized technique for assessing thyroid nodules; however, its inherent non-diagnostic rate poses diagnostic challenges. The present study aimed to evaluate and compare the diagnostic efficacy of FNA, core needle biopsy (CNB), and their combined application in the assessment of thyroid nodules.Methods: A total of 56 nodules from 50 patients was analyzed using both FNA and simultaneous CNB. The ultrasound characteristics were categorized according to the American College of Radiology Thyroid Imaging Reporting and Data Systems classification system. The study compared the sensitivity, specificity, and accuracy of FNA, CNB, and the combination of the two techniques.Results: The concordance between FNA and CNB was notably high, with a kappa coefficient of 0.837. The sensitivity for detecting thyroid malignancy was found to be 25.0% for FNA, 66.7% for CNB, and 83.3% for the combined FNA/CNB approach, with corresponding specificities of 84.6%, 97.4%, and 97.4%. The accuracy of the FNA/CNB combination was the highest at 94.1%.Conclusions: The findings of this study indicate that both CNB and the FNA/CNB combination offer greater diagnostic accuracy for thyroid malignancy compared to FNA alone, with no significant complications reported. Integrating CNB with FNA findings may enhance management strategies and treatment outcomes for patients with thyroid nodules.


  • Pathology-based radiation dose in computed tomography: investigation of the effect of lung lesions on water-equivalent diameter, CTDIVol and SSDE in COVID-19 patients

    by Ahmad Mohammadbeigi, Jalal Kargar Shouraki, Hojat Ebrahiminik, Majid Nouri, Hamed Bagheri, Hamid Moradi, Ahmad Azizi, Narges Fadaee, Taher Soltanzadeh, Yousef Moghimi

    Lung lesions can increase the CT number and affect the water-equivalent diameter (Dw), Dw-based conversion factor (CFw), and Dw-based size-specific dose estimate (SSDEw). We evaluated the effect of COVID-19 lesions and total severity score (TSS) on radiation dose considering the effect of automatic tube current modulation (ATCM) and fixed tube current (FTC). A total of 186 chest CT scans were categorised into five TSS groups, including healthy, minimal, mild, moderate and severe. The effective diameter (Deff), Dw, CFw, Deff-based conversion factor (CFeff), volume computed tomography dose index (CTDIVol), pathological dose impact factor (PDIF) 1 and SSDEw were calculated. TSS was correlated with Dw (r = 0.29, p-value = 0.001), CTDIVol (ATCM) (r = 0.23, p = 0.001) and PDIF (r = − 0.51, p-value = 0.001). $\overline{{\mathrm{SSDE}}_{\mathrm{w}}}$ (FTC) was significantly different among all groups. $\overline{{\mathrm{SSDE}}_{\mathrm{w}}}$ (ATCM) was greater for moderate (13%) and mild (14%) groups. Increasing TSS increase the Dw and causes a decrease in CFw and $\overline{{\mathrm{SSDE}}_{\mathrm{w}}}$ (FTC), and can increase $\overline{{\mathrm{SSDE}}_{\mathrm{w}}}$ (ATCM) in some Dw ranges.