Universal Bioinert Control of Polystyrene Interfaces via Hydrophobic‐Driven Self‐Assembled Surface PEGylation with a Well‐Defined Block Sequence
- 3 July 2017
- journal article
- research article
- Published by Wiley in Macromolecular Chemistry and Physics
- Vol. 218 (19)
Abstract
This work proposes a new molecular insight of interfacial design in the control of antifouling performance for the versatile biofoulants, including proteins, blood cells, tissue cells, and bacteria. A self‐assembled bioinert interface with universal fouling resistance to general biofoulants via hydrophobic‐driven surface PEGylation is presented. The study systematically discriminates the optimum PEGylated block polymer configuration and hydrophobic/hydrophilic segmental ratio enabling to optimize the surface coverage by the bioinert moieties, thus ensuring the best resistance to biofouling. For similar copolymer molecular weights and similar polystyrene (PS)/poly(ethylene glycol) methacrylate (PEGMA), the coating density obtainable is the highest if a random copolymer is used, while it is the lowest with a triblock copolymer. That measured with a diblock copolymer lies in between. Random copolymers offer more numerous anchoring possibilities than diblock copolymers, while they are importantly fewer if triblock copolymers are used. For similar total number of hydrophilic blocks, the diblock copolymer is more efficient to resist larger cells (leukocytes, fibroblasts) while the triblock is better to promote mitigate biofouling by smaller molecules or cells (proteins, platelets, red blood cells). The length of the hydrophilic PEGylated block seems to dominate fouling resistance of large biofoulants.Keywords
Funding Information
- Chung Yuan Christian University
- Ministry of Science and Technology, Taiwan (103-2221-E-033-078-MY3, 105-2119-M-008-006)
This publication has 51 references indexed in Scilit:
- Biofouling of Water Treatment Membranes: A Review of the Underlying Causes, Monitoring Techniques and Control MeasuresMembranes, 2012
- Blood‐Inert Surfaces via Ion‐Pair Anchoring of Zwitterionic Copolymer Brushes in Human Whole BloodAdvanced Functional Materials, 2012
- Biofouling Resistance of Ultrafiltration Membranes Controlled by Surface Self-Assembled Coating with PEGylated CopolymersLangmuir, 2011
- Investigation of the role of hydrophilic chain length in amphiphilic perfluoropolyether/poly(ethylene glycol) networks: towards high-performance antifouling coatingsBiofouling, 2011
- Surface Grafting Polyethylene Glycol (PEG) onto Poly(ethylene-co-acrylic acid) FilmsLangmuir, 2006
- Evaluation of measures to decrease intra-operative bacterial contamination in orthopaedic implant surgeryJournal of Hospital Infection, 2006
- Microbial Adhesion to Poly(ethylene oxide) Brushes: Influence of Polymer Chain Length and TemperatureLangmuir, 2004
- Surface modification of polysulfone membranes by low-temperature plasma-graft poly(ethylene glycol) onto polysulfone membranesJournal of Applied Polymer Science, 2000
- Preparation of anti‐oil stained membrane by grafting polyethylene glycol macromer onto polysulfone membraneJournal of Applied Polymer Science, 1994
- The platelet‐fibrinogen interactionEuropean Journal of Biochemistry, 1984