Lu-Chen Yeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lu-Chen Yeh has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
Jui-Ming Yeh
7 shared publications- Antoine Venault
R&D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung-Li, Taoyuan 320, Taiwan
6 shared publications Tsao-Cheng Huang
6 shared publications- Yung Chang
Chung Yuan Christian University Chung-Li
6 shared publications Hsiu-Ying Huang
Department of Chemistry and Center for Nanotechnology, Chung Yuan Christian University, Chung Li, Taiwan 32023, Republic of China
5 shared publications- An-Ya Lo
Department of Chemical and Materials Engineering, National Chin-Yi University of Technology, Taichung 411030, Taiwan
4 shared publications
Latest Publications
- 1 November 2018
- Published by Elsevier in Journal of Membrane Science
- Vol. 565, 119-130
Controlling the zwitterionization degree of alternate copolymers for minimizing biofouling on PVDF membranes
- 1 November 2018
- Published by Elsevier in Journal of Membrane Science
- Vol. 565, 119-130
Controlling the zwitterionization degree of alternate copolymers for minimizing biofouling on PVDF membranes
- 1 November 2018
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 529, 77-89
Bio-inert interfaces via biomimetic anchoring of a zwitterionic copolymer on versatile substrates
- 1 November 2018
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 529, 77-89
Bio-inert interfaces via biomimetic anchoring of a zwitterionic copolymer on versatile substrates
- 8 May 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 10 (21) , 17771-17783
Superior Bioinert Capability of Zwitterionic Poly(4-vinylpyridine propylsulfobetaine) Withstanding Clinical Sterilization for Extended Medical Applications
The field of bio-inert materials is relatively mature as unique molecular designs for antifouling have been regularly presented over the past 30 years. However, the effect of steam sterilization, a common procedure in hospitals for sterilizing biomedical devices in clinical uses, on the stability of antifouling and hemocompatible biomaterials remains unexplored. The only available set of data indicates that poly(sulfobetaine methacrylate) (SBMA) is unstable and loses its antifouling properties when exposed to hot humid air, depriving it of its attractiveness. Here, we present zwitterionic biomaterial gels of poly(4-vinylpyridine propylsulfobetaine) (4VPPS) and explore their propensity to biofouling before and after a 1h-steam sterilization at 121°C. After incubation with erythrocytes, leukocytes, thrombocytes, whole blood or various bacteria (Escherichia coli, Stenotrophomonas maltophilia), the antifouling properties of unsterilized 4VPPS gels are comparable to those of SBMA gels. Importantly, they are maintained after steam sterilization, unlike those of SBMA gels, which shows that the structure of 4VPPS and the interactions with water remain unaffected by the humid heat treatment. The antifouling properties of gels coated on materials mimicking surfaces used in biomedical devices including stainless steel (surgical knife), silicon (biochips) or titanium (electrocautery pen), are also maintained after similar sterilization. In addition, repeated sterilizations do not affect the antifouling properties of 4VPPS. Therefore, these results provide a substantial advance over the current knowledge on antifouling materials for repeated usage in actual conditions that often involve, in a biomedical environment, steam sterilization.
- 8 May 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 10 (21) , 17771-17783
Superior Bioinert Capability of Zwitterionic Poly(4-vinylpyridine propylsulfobetaine) Withstanding Clinical Sterilization for Extended Medical Applications
The field of bio-inert materials is relatively mature as unique molecular designs for antifouling have been regularly presented over the past 30 years. However, the effect of steam sterilization, a common procedure in hospitals for sterilizing biomedical devices in clinical uses, on the stability of antifouling and hemocompatible biomaterials remains unexplored. The only available set of data indicates that poly(sulfobetaine methacrylate) (SBMA) is unstable and loses its antifouling properties when exposed to hot humid air, depriving it of its attractiveness. Here, we present zwitterionic biomaterial gels of poly(4-vinylpyridine propylsulfobetaine) (4VPPS) and explore their propensity to biofouling before and after a 1h-steam sterilization at 121°C. After incubation with erythrocytes, leukocytes, thrombocytes, whole blood or various bacteria (Escherichia coli, Stenotrophomonas maltophilia), the antifouling properties of unsterilized 4VPPS gels are comparable to those of SBMA gels. Importantly, they are maintained after steam sterilization, unlike those of SBMA gels, which shows that the structure of 4VPPS and the interactions with water remain unaffected by the humid heat treatment. The antifouling properties of gels coated on materials mimicking surfaces used in biomedical devices including stainless steel (surgical knife), silicon (biochips) or titanium (electrocautery pen), are also maintained after similar sterilization. In addition, repeated sterilizations do not affect the antifouling properties of 4VPPS. Therefore, these results provide a substantial advance over the current knowledge on antifouling materials for repeated usage in actual conditions that often involve, in a biomedical environment, steam sterilization.
- 7 November 2017
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 3 (12) , 3338-3350
Turning Expanded Poly(tetrafluoroethylene) Membranes into Potential Skin Wound Dressings by Grafting a Bioinert Epoxylated PEGMA Copolymer
Despite a set of properties ideal to the design of wound-dressings, bio-inert membranes are seldom applied as wound-healing systems. This work presents a unique series of random copolymers of glycidyl methacrylate (GMA) and poly(ethylene glycol) methacrylate (PEGMA), namely GMA-r-PEGMA, used to surface-modify by grafting onto method polytetrafluorethylene membranes, with the aim of developing wound dressings for quick and efficient chronic wound closure. It is shown that the membrane modified with G50P50 copolymer combines high surface hydrophilicity, high porosity, protein resistance, bacterial resistance and hemocompatibility, essential properties to wound-dressings. Fibrinogen adsorption was measured to be 11.4 ± 3.9% (compared with virgin membrane) correlating with a low water contact angle (14°), while the attachment of fluorescent Escherichia coli after 24h, erythrocytes, leukocytes, thrombocytes and cells from whole blood was reduced by 85-90%, compared with the virgin membrane. G50P50 membrane was tested as a wound-dressing, which outperformed hydrophilic gels of PEGMA in terms of wound-closure kinetic and a commercial dressing in terms of homogeneity of the granulation layer. The facile surface-modification of ePTFE membrane using unique GMA-r-PEGMA copolymer leads to an anti-biofouling porous material with improved hemocompatibility combining numerous essential properties of wound-dressings and contributing towards the development of the ideal bandage.
- 7 November 2017
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 3 (12) , 3338-3350
Turning Expanded Poly(tetrafluoroethylene) Membranes into Potential Skin Wound Dressings by Grafting a Bioinert Epoxylated PEGMA Copolymer
Despite a set of properties ideal to the design of wound-dressings, bio-inert membranes are seldom applied as wound-healing systems. This work presents a unique series of random copolymers of glycidyl methacrylate (GMA) and poly(ethylene glycol) methacrylate (PEGMA), namely GMA-r-PEGMA, used to surface-modify by grafting onto method polytetrafluorethylene membranes, with the aim of developing wound dressings for quick and efficient chronic wound closure. It is shown that the membrane modified with G50P50 copolymer combines high surface hydrophilicity, high porosity, protein resistance, bacterial resistance and hemocompatibility, essential properties to wound-dressings. Fibrinogen adsorption was measured to be 11.4 ± 3.9% (compared with virgin membrane) correlating with a low water contact angle (14°), while the attachment of fluorescent Escherichia coli after 24h, erythrocytes, leukocytes, thrombocytes and cells from whole blood was reduced by 85-90%, compared with the virgin membrane. G50P50 membrane was tested as a wound-dressing, which outperformed hydrophilic gels of PEGMA in terms of wound-closure kinetic and a commercial dressing in terms of homogeneity of the granulation layer. The facile surface-modification of ePTFE membrane using unique GMA-r-PEGMA copolymer leads to an anti-biofouling porous material with improved hemocompatibility combining numerous essential properties of wound-dressings and contributing towards the development of the ideal bandage.
- 5 September 2017
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 33 (38) , 9822-9835
Epoxylated Zwitterionic Triblock Copolymers Grafted onto Metallic Surfaces for General Biofouling Mitigation
Titanium and stainless steel materials are widely used in numerous devices or in custom parts for their excellent mechanical properties. However, their lack of biocompatibility seriously limits their usage in the biomedical field. This study focuses on the grafting of triblock copolymers on titanium and stainless steel metal susbtrates for improving their general biofouling resistance. The series of copolymers that we designed is composed of two blocks of zwitterionic sulfobetaine (SBMA) monomers and one block of glycidyl methacrylate (GMA). The number of repeat units forming each block, n, was finely tuned and controlled to 25, 50, 75, or 100, permitting regulation of the grafting thickness, the morphology, and the dependent properties such as the surface hydrophilicity and biofouling resistance. It was shown that the copolymer possessing n = 50 repeat units in each block, corresponding to a molecular weight of about 15.2 kDa, led to the best nonfouling properties, assessed using plasma proteins, blood cells, fibroblasts cells, and various bacteria. This was explained by an optimized grafting degree and chain organization of the copolymer. Lower value (n = 25) and higher values (n = 75, 100) led to low surface coverage and the formation of aggregates, respectively. The best copolymer was grafted onto scalpels (steel) and dental roots (titanium), and antifouling properties demonstrated using Escherichia coli and HT1080 cells. Results of this work show that this unique triblock copolymer holds promise as a potential material for surface modification of biomedical metallic devices, provided a fine-tuning of the blocks organization and length.
- 5 September 2017
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 33 (38) , 9822-9835
Epoxylated Zwitterionic Triblock Copolymers Grafted onto Metallic Surfaces for General Biofouling Mitigation
Titanium and stainless steel materials are widely used in numerous devices or in custom parts for their excellent mechanical properties. However, their lack of biocompatibility seriously limits their usage in the biomedical field. This study focuses on the grafting of triblock copolymers on titanium and stainless steel metal susbtrates for improving their general biofouling resistance. The series of copolymers that we designed is composed of two blocks of zwitterionic sulfobetaine (SBMA) monomers and one block of glycidyl methacrylate (GMA). The number of repeat units forming each block, n, was finely tuned and controlled to 25, 50, 75, or 100, permitting regulation of the grafting thickness, the morphology, and the dependent properties such as the surface hydrophilicity and biofouling resistance. It was shown that the copolymer possessing n = 50 repeat units in each block, corresponding to a molecular weight of about 15.2 kDa, led to the best nonfouling properties, assessed using plasma proteins, blood cells, fibroblasts cells, and various bacteria. This was explained by an optimized grafting degree and chain organization of the copolymer. Lower value (n = 25) and higher values (n = 75, 100) led to low surface coverage and the formation of aggregates, respectively. The best copolymer was grafted onto scalpels (steel) and dental roots (titanium), and antifouling properties demonstrated using Escherichia coli and HT1080 cells. Results of this work show that this unique triblock copolymer holds promise as a potential material for surface modification of biomedical metallic devices, provided a fine-tuning of the blocks organization and length.
- 3 July 2017
- Published by Wiley in Macromolecular Chemistry and Physics
- Vol. 218 (19)
Universal Bioinert Control of Polystyrene Interfaces via Hydrophobic‐Driven Self‐Assembled Surface PEGylation with a Well‐Defined Block Sequence
This work proposes a new molecular insight of interfacial design in the control of antifouling performance for the versatile biofoulants, including proteins, blood cells, tissue cells, and bacteria. A self‐assembled bioinert interface with universal fouling resistance to general biofoulants via hydrophobic‐driven surface PEGylation is presented. The study systematically discriminates the optimum PEGylated block polymer configuration and hydrophobic/hydrophilic segmental ratio enabling to optimize the surface coverage by the bioinert moieties, thus ensuring the best resistance to biofouling. For similar copolymer molecular weights and similar polystyrene (PS)/poly(ethylene glycol) methacrylate (PEGMA), the coating density obtainable is the highest if a random copolymer is used, while it is the lowest with a triblock copolymer. That measured with a diblock copolymer lies in between. Random copolymers offer more numerous anchoring possibilities than diblock copolymers, while they are importantly fewer if triblock copolymers are used. For similar total number of hydrophilic blocks, the diblock copolymer is more efficient to resist larger cells (leukocytes, fibroblasts) while the triblock is better to promote mitigate biofouling by smaller molecules or cells (proteins, platelets, red blood cells). The length of the hydrophilic PEGylated block seems to dominate fouling resistance of large biofoulants.
- 3 July 2017
- Published by Wiley in Macromolecular Chemistry and Physics
- Vol. 218 (19)
Universal Bioinert Control of Polystyrene Interfaces via Hydrophobic‐Driven Self‐Assembled Surface PEGylation with a Well‐Defined Block Sequence
This work proposes a new molecular insight of interfacial design in the control of antifouling performance for the versatile biofoulants, including proteins, blood cells, tissue cells, and bacteria. A self‐assembled bioinert interface with universal fouling resistance to general biofoulants via hydrophobic‐driven surface PEGylation is presented. The study systematically discriminates the optimum PEGylated block polymer configuration and hydrophobic/hydrophilic segmental ratio enabling to optimize the surface coverage by the bioinert moieties, thus ensuring the best resistance to biofouling. For similar copolymer molecular weights and similar polystyrene (PS)/poly(ethylene glycol) methacrylate (PEGMA), the coating density obtainable is the highest if a random copolymer is used, while it is the lowest with a triblock copolymer. That measured with a diblock copolymer lies in between. Random copolymers offer more numerous anchoring possibilities than diblock copolymers, while they are importantly fewer if triblock copolymers are used. For similar total number of hydrophilic blocks, the diblock copolymer is more efficient to resist larger cells (leukocytes, fibroblasts) while the triblock is better to promote mitigate biofouling by smaller molecules or cells (proteins, platelets, red blood cells). The length of the hydrophilic PEGylated block seems to dominate fouling resistance of large biofoulants.
- 1 March 2017
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 151, 372-383
Surface charge-bias impact of amine-contained pseudozwitterionic biointerfaces on the human blood compatibility
- 1 March 2017
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 151, 372-383
Surface charge-bias impact of amine-contained pseudozwitterionic biointerfaces on the human blood compatibility
- 1 October 2016
- Published by Elsevier in Surface and Coatings Technology
- Vol. 303, 154-161
Synthesis of electroactive polyazomethine and its application in electrochromic property and electrochemical sensor
- 1 October 2016
- Published by Elsevier in Surface and Coatings Technology
- Vol. 303, 154-161
Synthesis of electroactive polyazomethine and its application in electrochromic property and electrochemical sensor
- 21 September 2016
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 14 (2) , 113-120
Advanced superhydrophobic electroactive fluorinated polyimide and its application in anticorrosion coating
A novel superhydrophobicelectroactive fluorinated polyimide (HEFPI) was first synthesized from aniline trimer and 4,4′-(Hexafluoroisopropylidene) diphthalic anhydride. The HEFPI could be fabricated as superhydrophobicfilm by replicated the surface of the Xanthosomasagittifolium leaves. The water contact angle of HEFPI film reaches as high as 157 ° and the superhydrophobic property of HEFPI could coat on cold-rolled steel (CRS) to prevent the metal corrosion. Electroactivity of EFPI was evaluated by performing electrochemical cyclic voltammetry study. Besides, redox catalytic capabilities of aniline trimer units existed in HEFPI main chain may induce the formation of passive metal oxide layers on the CRS electrode. The synergistic effects (hydrophobic property and passive metal oxide layers) make the HEFPI coating has great potential for advanced anticorrosion material.
- 21 September 2016
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 14 (2) , 113-120
Advanced superhydrophobic electroactive fluorinated polyimide and its application in anticorrosion coating
A novel superhydrophobicelectroactive fluorinated polyimide (HEFPI) was first synthesized from aniline trimer and 4,4′-(Hexafluoroisopropylidene) diphthalic anhydride. The HEFPI could be fabricated as superhydrophobicfilm by replicated the surface of the Xanthosomasagittifolium leaves. The water contact angle of HEFPI film reaches as high as 157 ° and the superhydrophobic property of HEFPI could coat on cold-rolled steel (CRS) to prevent the metal corrosion. Electroactivity of EFPI was evaluated by performing electrochemical cyclic voltammetry study. Besides, redox catalytic capabilities of aniline trimer units existed in HEFPI main chain may induce the formation of passive metal oxide layers on the CRS electrode. The synergistic effects (hydrophobic property and passive metal oxide layers) make the HEFPI coating has great potential for advanced anticorrosion material.
- 6 July 2016
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 13 (13) , 1334-1341
Electroactive polyamide modified carbon paste electrode for the determination of ascorbic acid
S Construction electroactive polyamide (EPA) with aniline-pentamer-based in the main chain has been modified on the surface of carbon paste electrode (CPE) for detecting ascorbic acid (AA). Fourier transform infrared spectroscopy and nuclear magnetic resonance spectroscopy studies confirm the well-defined molecular structure of the oligoaniline and EPA. Further, the in situ chemical oxidation of EPA was monitored by UV-Visible absorption spectrum. The electroactivity of the EPA was evaluated by performing electrochemical cyclic voltammetry study. The sensing response studies have revealed that this EPA-modified CPE electrode can detect AA in the range of 0.05–0.7 mM with detection limit of 0.005 mM and sensitivity of 1.5 × 10–5 AmM–1. Besides, this EPA-modified CPE electrode shows a minimal relative standard deviation of 1.73%.
- 6 July 2016
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 13 (13) , 1334-1341
Electroactive polyamide modified carbon paste electrode for the determination of ascorbic acid
S Construction electroactive polyamide (EPA) with aniline-pentamer-based in the main chain has been modified on the surface of carbon paste electrode (CPE) for detecting ascorbic acid (AA). Fourier transform infrared spectroscopy and nuclear magnetic resonance spectroscopy studies confirm the well-defined molecular structure of the oligoaniline and EPA. Further, the in situ chemical oxidation of EPA was monitored by UV-Visible absorption spectrum. The electroactivity of the EPA was evaluated by performing electrochemical cyclic voltammetry study. The sensing response studies have revealed that this EPA-modified CPE electrode can detect AA in the range of 0.05–0.7 mM with detection limit of 0.005 mM and sensitivity of 1.5 × 10–5 AmM–1. Besides, this EPA-modified CPE electrode shows a minimal relative standard deviation of 1.73%.