A new device for performing reference point indentation without a reference probe
Authors:
- 1 April 2012
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (4) , 044301
Abstract
Here we describe a novel, hand-held reference point indentation (RPI), instrument that is designed for clinical measurements of bone material properties in living patients. This instrument differs from previous RPI instruments in that it requires neither a reference probe nor removal of the periosteum that covers the bone, thus significantly simplifying its use in patient testing. After describing the instrument, we discuss five guidelines for optimal and reproducible results. These are: (1) the angle between the normal to the surface and the axis of the instrument should be less than 10°, (2) the compression of the main spring to trigger the device must be performed slowly (>1 s), (3) the probe tip should be sharper than 10 μm; however, a normalized parameter with a calibration phantom can correct for dull tips up to a 100 μm radius, (4) the ambient room temperature should be between 4 °C and 37 °C, and (5) the effective mass of the bone or material under test must exceed 1 kg, or if under 1 kg, the specimen should be securely anchored in a fixation device with sufficient mass (which is not a requirement of previous RPI instruments). Our experience is that a person can be trained with these guidelines in about 5 min and thereafter obtain accurate and reproducible results. The portability, ease of use, and minimal training make this instrument suitable to measure bone material properties in a clinical setting.Keywords
Funding Information
- National Institutes of Health (RO1 GM 065354)
This publication has 9 references indexed in Scilit:
- Microindentation for in vivo measurement of bone tissue mechanical properties in humansJournal of Bone and Mineral Research, 2010
- The tissue diagnostic instrumentReview of Scientific Instruments, 2009
- The bone diagnostic instrument II: Indentation distance increaseReview of Scientific Instruments, 2008
- Insights into Material and Structural Basis of Bone Fragility from Diseases Associated with Fractures: How Determinants of the Biomechanical Properties of Bone Are Compromised by DiseaseEndocrine Reviews, 2006
- Bone diagnostic instrumentReview of Scientific Instruments, 2006
- Age-Dependent Biomechanical Modifications in BoneCritical Reviews™ in Eukaryotic Gene Expression, 2005
- Estimation of the Young's modulus of articular cartilage using an arthroscopic indentation instrument and ultrasonic measurement of tissue thicknessJournal of Biomechanics, 2001
- Indentation instrument for the measurement of cartilage stiffness under arthroscopic controlMedical Engineering & Physics, 1995
- Changes in the impact energy absorption of bone with ageJournal of Biomechanics, 1979