Reliability of nocturnal blood pressure dipping
Authors:
- Joel E. DimsdaleJDJoel E. Dimsdale
- Roland von KänelRKRoland von Känel
- Judi ProfantJPJudi Profant
- Richard NelesenRNRichard Nelesen
- Sonia Ancoli-IsraelSASonia Ancoli-Israel
- Michael ZieglerMZMichael Ziegler
- 1 August 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 5 (4) , 217-221
Abstract
Increasing evidence documents the fact that individuals whose blood pressure drops or ‘dips’ relatively little at night have a higher risk of numerous cardiovascular illnesses. To examine the reliability of various measures of nocturnal blood pressure dipping. This study examined 17 individuals with ambulatory blood pressure monitoring on three 24 h recordings while they pursued a schedule similar to that of in-patients on a clinical research unit. Nocturnal dipping of blood pressure was scored three ways: as the drop in blood pressure between 10 p.m. and 6 a.m. (‘clocktime’), as the drop in blood pressure tailored to each individual's reported bedtime (‘bedtime’), and as the drop in blood pressure accompanying polysomnographically verified sleep (‘sleeptime’). Adequate reliability was obtained for all three measures of dipping. There was, in general, a significant correlation across testing occasions (P < 0.05). The correlation coefficient ranged from 0.5 to 0.8, depending on which criterion of dipping was selected and whether the endpoint was systolic blood pressure, diastolic blood pressure, or mean arterial blood pressure. The reliability of systolic blood pressure dipping was somewhat lower than that of diastolic or mean arterial blood pressure dipping. Dipping appears to be a reliable construct. While no one definition of dipping was demonstrably better than another, the most sensible definition of dipping would allow some adjustment for defining ‘night’ on the basis of each individual's idiosyncratic bed time.Keywords
This publication has 25 references indexed in Scilit:
- Effect of Continuous Positive Airway Pressure on Blood PressureHypertension, 2000
- Ambulatory blood pressure nondipping status in salt-sensitive and salt-resistant black adolescentsAmerican Journal of Hypertension, 1999
- Marital cohesion and ambulatory blood pressure in early hypertensionAmerican Journal of Hypertension, 1999
- How Reliable Is Nighttime Blood Pressure Dipping?American Journal of Hypertension, 1998
- Limited Reproducibility of Circadian Variation in Blood Pressure Dippers and NondippersAmerican Journal of Hypertension, 1998
- Ambulatory Blood Pressure Monitoring: How Reproducible Is It?American Journal of Hypertension, 1997
- Altered blood pressure profile, autonomic neuropathy and nephropathy in insulin-dependent diabetic patientsEuropean Journal of Endocrinology, 1996
- Does it matter whether ambulatory blood pressure is recorded during a work day or a non-work day?Journal Of Hypertension, 1996
- Reproducibility of the circadian systolic blood pressure variation in the elderlyJournal Of Hypertension, 1995
- Test-retest reliability of 24-hour ambulatory blood pressuresApplied Psychophysiology and Biofeedback, 1995