Signal processing in urodynamics: towards high definition urethral pressure profilometry
Open Access
- 22 March 2016
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (1) , 1-24
Abstract
Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI) which is a significant medical, social, and economic problem. Low spatial pressure resolution, common occurrence of artifacts, and uncertainties in data location limit the diagnostic value of UPP. To overcome these limitations, high definition urethral pressure profilometry (HD-UPP) combining enhanced UPP hardware and signal processing algorithms has been developed. In this work, we present the different signal processing steps in HD-UPP and show experimental results from female minipigs. We use a special microtip catheter with high angular pressure resolution and an integrated inclination sensor. Signals from the catheter are filtered and time-correlated artifacts removed. A signal reconstruction algorithm processes pressure data into a detailed pressure image on the urethra’s inside. Finally, the pressure distribution on the urethra’s outside is calculated through deconvolution. A mathematical model of the urethra is contained in a point-spread-function (PSF) which is identified depending on geometric and material properties of the urethra. We additionally investigate the PSF’s frequency response to determine the relevant frequency band for pressure information on the urinary sphincter. Experimental pressure data are spatially located and processed into high resolution pressure images. Artifacts are successfully removed from data without blurring other details. The pressure distribution on the urethra’s outside is reconstructed and compared to the one on the inside. Finally, the pressure images are mapped onto the urethral geometry calculated from inclination and position data to provide an integrated image of pressure distribution, anatomical shape, and location. With its advanced sensing capabilities, the novel microtip catheter collects an unprecedented amount of urethral pressure data. Through sequential signal processing steps, physicians are provided with detailed information on the pressure distribution in and around the urethra. Therefore, HD-UPP overcomes many current limitations of conventional UPP and offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct anatomical location. This could enable the development of focal therapy approaches in the treatment of SUI.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (ID0ELKAE881)
- Deutsche Forschungsgemeinschaft (ID0ELKAE882)
- Deutsche Forschungsgemeinschaft (ID0ELKAE883)
- Deutsche Forschungsgemeinschaft (ID0ELKAE884)
- Deutsche Forschungsgemeinschaft (ID0ELKAE885)
- Deutsche Forschungsgemeinschaft (ID0ELKAE886)
- Deutsche Forschungsgemeinschaft (ID0ELKAE887)
- Deutsche Forschungsgemeinschaft (ID0ELKAE888)
This publication has 27 references indexed in Scilit:
- An Anatomical Description of the Male and Female Urethral Sphincter ComplexJournal of Urology, 2004
- Standardisation of urethral pressure measurement: Report from the standardisation sub‐committee of the International Continence SocietyNeurourology and Urodynamics, 2002
- Comparison of microtransducer and fiberoptic catheters for urodynamic studiesObstetrics & Gynecology, 2001
- Determining the initial states in forward-backward filteringIEEE Transactions on Signal Processing, 1996
- Pressure measurement techniques in urodynamic investigationsNeurourology and Urodynamics, 1990
- Two-dimensional nonuniform sampling expansions an iterative approach. ii. reconstruction formulae and applicationsApplicable Analysis, 1989
- Two-dimensional nonuniform sampling expansions an iterative approach. i. theory of two-dimensional bandlimited signalsApplicable Analysis, 1989
- Pressure variations in the female urethra measured by the infusion technique: Is it an artifact?Neurourology and Urodynamics, 1988
- 5-Microtransducer catheter in evaluation of neurogenic bladder functionUrology, 1986
- Continuous recording of urethral activity in healthy female volunteersNeurourology and Urodynamics, 1986