Mario Klünder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mario Klünder has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Alexandra Kelp
Department of Urology University of Tübingen Tübingen Germany
2 shared publicationsArnulf Stenzl
Department of Urology University of Tübingen Tübingen Germany
2 shared publications- Arnulf Stenzl
Department of Urology, Eberhard-Karls-University, 72074 Tuebingen, Germany
2 shared publications Bastian Amend
Department of Urology University of Tübingen Tübingen Germany
2 shared publications- Bastian Amend
Department of Urology, University of Tuebingen Hospital, 72076 Tuebingen, Germany
2 shared publications - Karl-Dietrich Sievert
Department of Urology, Medical School and University Medical Center OWL, Campus Klinikum Lippe, Bielefeld University, Detmold, Germany
2 shared publications
Latest Publications
- 30 August 2016
- Published by Wiley in Neurourology and Urodynamics
- Vol. 36 (5) , 1292-1300
Assessing the reproducibility of high definition urethral pressure profilometry and its correlation with an air‐charged system
Introduction: Recently, a new urodynamic method for the assessment of stress urinary incontinence called high definition urethral pressure profilometry (HD‐UPP) has been introduced. This method combines a novel microtip catheter with advanced signal processing to enable spatial data location and the reconstruction of a pressure image inside the urethra. In order to assess the reproducibility of HD‐UPP data, we statistically evaluate HD‐UPP datasets and compare them to data from a double balloon air‐charged system.Materials and Methods: Both catheters are used on sedated female minipigs. Data from the microtip catheter are processed through a signal reconstruction algorithm, urodynamic features are extracted, and compared to the air‐charged system. Reproducibility of HD‐UPP data is assessed by statistically evaluating consecutive, intra‐individual datasets.Results: HD‐UPP delivers results in agreement with previous comparisons of microtip and air‐charged systems. The average deviation of two consecutive, intra‐individual pressure images is very low at 7 cm H2O.Conclusions: HD‐UPP provides physicians with detailed information on the pressure distribution inside the urethra. Through comparison with an air‐charged catheter, it is shown that HD‐UPP delivers results in agreement with previous studies on the comparison of microtip and air‐charged catheters. It provides excellent reproducibility, as the difference between sequentially measured profiles from the same minipig is significantly lower than the one between profiles from different minipigs.
- 30 August 2016
- Published by Wiley in Neurourology and Urodynamics
- Vol. 36 (5) , 1292-1300
Assessing the reproducibility of high definition urethral pressure profilometry and its correlation with an air‐charged system
Introduction: Recently, a new urodynamic method for the assessment of stress urinary incontinence called high definition urethral pressure profilometry (HD‐UPP) has been introduced. This method combines a novel microtip catheter with advanced signal processing to enable spatial data location and the reconstruction of a pressure image inside the urethra. In order to assess the reproducibility of HD‐UPP data, we statistically evaluate HD‐UPP datasets and compare them to data from a double balloon air‐charged system.Materials and Methods: Both catheters are used on sedated female minipigs. Data from the microtip catheter are processed through a signal reconstruction algorithm, urodynamic features are extracted, and compared to the air‐charged system. Reproducibility of HD‐UPP data is assessed by statistically evaluating consecutive, intra‐individual datasets.Results: HD‐UPP delivers results in agreement with previous comparisons of microtip and air‐charged systems. The average deviation of two consecutive, intra‐individual pressure images is very low at 7 cm H2O.Conclusions: HD‐UPP provides physicians with detailed information on the pressure distribution inside the urethra. Through comparison with an air‐charged catheter, it is shown that HD‐UPP delivers results in agreement with previous studies on the comparison of microtip and air‐charged catheters. It provides excellent reproducibility, as the difference between sequentially measured profiles from the same minipig is significantly lower than the one between profiles from different minipigs.
- Open Access
- 22 March 2016
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (1) , 1-24
Signal processing in urodynamics: towards high definition urethral pressure profilometry
Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI) which is a significant medical, social, and economic problem. Low spatial pressure resolution, common occurrence of artifacts, and uncertainties in data location limit the diagnostic value of UPP. To overcome these limitations, high definition urethral pressure profilometry (HD-UPP) combining enhanced UPP hardware and signal processing algorithms has been developed. In this work, we present the different signal processing steps in HD-UPP and show experimental results from female minipigs. We use a special microtip catheter with high angular pressure resolution and an integrated inclination sensor. Signals from the catheter are filtered and time-correlated artifacts removed. A signal reconstruction algorithm processes pressure data into a detailed pressure image on the urethra’s inside. Finally, the pressure distribution on the urethra’s outside is calculated through deconvolution. A mathematical model of the urethra is contained in a point-spread-function (PSF) which is identified depending on geometric and material properties of the urethra. We additionally investigate the PSF’s frequency response to determine the relevant frequency band for pressure information on the urinary sphincter. Experimental pressure data are spatially located and processed into high resolution pressure images. Artifacts are successfully removed from data without blurring other details. The pressure distribution on the urethra’s outside is reconstructed and compared to the one on the inside. Finally, the pressure images are mapped onto the urethral geometry calculated from inclination and position data to provide an integrated image of pressure distribution, anatomical shape, and location. With its advanced sensing capabilities, the novel microtip catheter collects an unprecedented amount of urethral pressure data. Through sequential signal processing steps, physicians are provided with detailed information on the pressure distribution in and around the urethra. Therefore, HD-UPP overcomes many current limitations of conventional UPP and offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct anatomical location. This could enable the development of focal therapy approaches in the treatment of SUI.
- 22 March 2016
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (1) , 1-24
Open AccessSignal processing in urodynamics: towards high definition urethral pressure profilometry
Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI) which is a significant medical, social, and economic problem. Low spatial pressure resolution, common occurrence of artifacts, and uncertainties in data location limit the diagnostic value of UPP. To overcome these limitations, high definition urethral pressure profilometry (HD-UPP) combining enhanced UPP hardware and signal processing algorithms has been developed. In this work, we present the different signal processing steps in HD-UPP and show experimental results from female minipigs. We use a special microtip catheter with high angular pressure resolution and an integrated inclination sensor. Signals from the catheter are filtered and time-correlated artifacts removed. A signal reconstruction algorithm processes pressure data into a detailed pressure image on the urethra’s inside. Finally, the pressure distribution on the urethra’s outside is calculated through deconvolution. A mathematical model of the urethra is contained in a point-spread-function (PSF) which is identified depending on geometric and material properties of the urethra. We additionally investigate the PSF’s frequency response to determine the relevant frequency band for pressure information on the urinary sphincter. Experimental pressure data are spatially located and processed into high resolution pressure images. Artifacts are successfully removed from data without blurring other details. The pressure distribution on the urethra’s outside is reconstructed and compared to the one on the inside. Finally, the pressure images are mapped onto the urethral geometry calculated from inclination and position data to provide an integrated image of pressure distribution, anatomical shape, and location. With its advanced sensing capabilities, the novel microtip catheter collects an unprecedented amount of urethral pressure data. Through sequential signal processing steps, physicians are provided with detailed information on the pressure distribution in and around the urethra. Therefore, HD-UPP overcomes many current limitations of conventional UPP and offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct anatomical location. This could enable the development of focal therapy approaches in the treatment of SUI.
- 24 July 2015
- Published by Wiley in Neurourology and Urodynamics
- Vol. 35 (8) , 888-894
High definition urethral pressure profilometry: Evaluating a novel microtip catheter
The ability of air-charged catheters to measure pressure circumferentially is widely considered a main advantage over microtip catheters. However, directional pressure readings can provide additional information on angular fluctuations in the urethral pressure distribution. It is shown that the novel microtip catheter in combination with a signal reconstruction algorithm delivers plausible data. It offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct location within the anatomical location of the pelvic floor. Neurourol. Urodynam. 35:888-894, 2016. © 2015 Wiley Periodicals, Inc.
- 24 July 2015
- Published by Wiley in Neurourology and Urodynamics
- Vol. 35 (8) , 888-894
High definition urethral pressure profilometry: Evaluating a novel microtip catheter
The ability of air-charged catheters to measure pressure circumferentially is widely considered a main advantage over microtip catheters. However, directional pressure readings can provide additional information on angular fluctuations in the urethral pressure distribution. It is shown that the novel microtip catheter in combination with a signal reconstruction algorithm delivers plausible data. It offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct location within the anatomical location of the pelvic floor. Neurourol. Urodynam. 35:888-894, 2016. © 2015 Wiley Periodicals, Inc.
- Open Access
- 24 February 2014
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 3 (1) , 197-215
Towards a Treatment of Stress Urinary Incontinence: Application of Mesenchymal Stromal Cells for Regeneration of the Sphincter Muscle
Stress urinary incontinence is a significant social, medical, and economic problem. It is caused, at least in part, by degeneration of the sphincter muscle controlling the tightness of the urinary bladder. This muscular degeneration is characterized by a loss of muscle cells and a surplus of a fibrous connective tissue. In Western countries approximately 15% of all females and 10% of males are affected. The incidence is significantly higher among senior citizens, and more than 25% of the elderly suffer from incontinence. When other therapies, such as physical exercise, pharmacological intervention, or electrophysiological stimulation of the sphincter fail to improve the patient’s conditions, a cell-based therapy may improve the function of the sphincter muscle. Here, we briefly summarize current knowledge on stem cells suitable for therapy of urinary incontinence: mesenchymal stromal cells, urine-derived stem cells, and muscle-derived satellite cells. In addition, we report on ways to improve techniques for surgical navigation, injection of cells in the sphincter muscle, sensors for evaluation of post-treatment therapeutic outcome, and perspectives derived from recent pre-clinical studies.
- 24 February 2014
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 3 (1) , 197-215
Open AccessTowards a Treatment of Stress Urinary Incontinence: Application of Mesenchymal Stromal Cells for Regeneration of the Sphincter Muscle
Stress urinary incontinence is a significant social, medical, and economic problem. It is caused, at least in part, by degeneration of the sphincter muscle controlling the tightness of the urinary bladder. This muscular degeneration is characterized by a loss of muscle cells and a surplus of a fibrous connective tissue. In Western countries approximately 15% of all females and 10% of males are affected. The incidence is significantly higher among senior citizens, and more than 25% of the elderly suffer from incontinence. When other therapies, such as physical exercise, pharmacological intervention, or electrophysiological stimulation of the sphincter fail to improve the patient’s conditions, a cell-based therapy may improve the function of the sphincter muscle. Here, we briefly summarize current knowledge on stem cells suitable for therapy of urinary incontinence: mesenchymal stromal cells, urine-derived stem cells, and muscle-derived satellite cells. In addition, we report on ways to improve techniques for surgical navigation, injection of cells in the sphincter muscle, sensors for evaluation of post-treatment therapeutic outcome, and perspectives derived from recent pre-clinical studies.