Research on the Design of Axial Uniform Coils for Residual Field Compensation in Magnetically Shielded Cylinder
- 5 July 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Abstract
A novel method to design highly uniform axial coils inside a closed magnetically shielded cylinder (MSC) is presented. The proposed method has two major advantages over existing methods. First, based on the coupling model of coil and MSC with finite permeability and finite thickness, the image method and target-field method (TFM) are introduced to provide a flexible design method for the coil inside the MSC. Second, a backpropagation neural network (BPNN) model and particle swarm optimization (PSO) algorithm are used to predict and optimize the coil parameters, thus reducing the magnetic field deviation caused by the use of discrete wires to approximate the continuous current density. Simulations indicate that this method reduces the magnetic field deviation within the target region from $2.63 \times 10^{-3}$ to $1.13 \times 10^{-4}$ compared with the coils designed using the TFM without consideration of the coupling effect. The magnetic field deviation is reduced from $1.42 \times 10^{-4}$ to $1.13 \times 10^{-4}$ compared with the coils designed in the ideal magnetic conductor. Moreover, the field deviation is reduced to $2.43 \times 10^{-5}$ after optimization using the BPNN and PSO methods. The experimental results also verify the effectiveness of the design method and its practicability in compensating for the residual field of the MSC. The method proposed in this research has major significance for the establishment of practical magnetoencephalography and magnetocardiography measurement systems.Keywords
Funding Information
- National Natural Science Foundation of China (51775017)
- Aeronautical Science Foundation of China (2019ZC051003)
- Key Research and Development Program of Zhejiang, China (2020C01037)
This publication has 33 references indexed in Scilit:
- A 20-channel magnetoencephalography system based on optically pumped magnetometersPhysics in Medicine & Biology, 2017
- ECG Signal Analysis Using DCT-Based DOST and PSO Optimized SVMIEEE Transactions on Instrumentation and Measurement, 2017
- General Solution of the Hollow Cylinder and Concentric DC Surface CurrentIEEE Magnetics Letters, 2014
- Brief Introduction of Back Propagation (BP) Neural Network Algorithm and Its Improvement2012
- A low-noise ferrite magnetic shieldApplied Physics Letters, 2007
- Active shielding of cylindrical saddle-shaped coils: Application to wire-wound RF coils for very low field NMR and MRIJournal of Magnetic Resonance, 2005
- Empirical study of particle swarm optimization2003
- A novel target-field method for magnetic resonance shim coils: III. Shielded zonal and tesseral coilsJournal of Physics D: Applied Physics, 2002
- The improvements of BP neural network learning algorithm2002