Fengwen Zhao
Research Subjects
Research Interests
Fengwen Zhao has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Xiangyang Zhou
Beihang University
12 shared publications - Weiqian Wang
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
11 shared publications - Haifeng Zhang
School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, China
10 shared publications - Xiaoxuan Xie
School of Instrumentation and Optoelectronic Engineering, Institute of Large-Scale Scientific Facility and Center for Zero Magnetic Field Science, Beihang University, Beijing, China
9 shared publications - Weiyong Zhou
Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure, Hangzhou, China
6 shared publications - Shiqiang Zheng
Beihang University
5 shared publications
Latest Publications
- 23 October 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 412
Design and experimental validation of a high-precision triaxial active geomagnetic compensation system
- 23 October 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 412
Design and experimental validation of a high-precision triaxial active geomagnetic compensation system
- Open Access
- 14 July 2026
- Published by Elsevier in NeuroImage
- Vol. 338, 122112
Bias-correction subspace projection method for background noise suppression in OPM-MEG systems
- 14 July 2026
- Published by Elsevier in NeuroImage
- Vol. 338, 122112
Open AccessBias-correction subspace projection method for background noise suppression in OPM-MEG systems
- 28 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-12
Two-Stage Nested Magnetic Field Control System Based on Time-Frequency Domain Collaboration for Magnetically Shielded Room
The complex electromagnetic disturbances often result in excessively high magnetic field noise. This article proposes a two-stage nested magnetic field control system based on time-frequency domain collaboration for a magnetically shielded room (MSR) to suppress the disturbance magnetic field and reduce magnetic field noise. The system creates a high-bandwidth external control system by placing external auxiliary coils and a fluxgate sensor outside the MSR, avoiding mutual interference with the internal control system. Subsequently, the system uses a self-tuning proportional-integral-derivative (PID) based on pole placement control and the gradient algorithm based on discrete Fourier transform to obtain the optimal internal noise level. This proposed method has effectively increased the control bandwidth while avoiding the design of complex two-stage decoupling strategies. Compared with the traditional only internal control system, the average noise suppression ability within the target frequency band has been improved by more than 20 $\mathbf{\%}$ .
- 28 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-12
Two-Stage Nested Magnetic Field Control System Based on Time-Frequency Domain Collaboration for Magnetically Shielded Room
The complex electromagnetic disturbances often result in excessively high magnetic field noise. This article proposes a two-stage nested magnetic field control system based on time-frequency domain collaboration for a magnetically shielded room (MSR) to suppress the disturbance magnetic field and reduce magnetic field noise. The system creates a high-bandwidth external control system by placing external auxiliary coils and a fluxgate sensor outside the MSR, avoiding mutual interference with the internal control system. Subsequently, the system uses a self-tuning proportional-integral-derivative (PID) based on pole placement control and the gradient algorithm based on discrete Fourier transform to obtain the optimal internal noise level. This proposed method has effectively increased the control bandwidth while avoiding the design of complex two-stage decoupling strategies. Compared with the traditional only internal control system, the average noise suppression ability within the target frequency band has been improved by more than 20 $\mathbf{\%}$ .
- 21 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-10
Two-Stage Synergistic Compensation Method Regulates Disturbance Magnetic Field in MSC for High Quality MCG Measurement
Magnetocardiography (MCG) is critical for early diagnosis and treatment of cardiac diseases. Arrayed SERF atomic magnetometers deliver high-quality MCG in a near-zero field provided by a magnetic shielding cylinder (MSC) with active magnetic compensation (AMC). However, the magnetic noise within the MSC is dynamic and gradient-distributed, making conventional single-stage uniform-field AMC inadequate. To overcome this, we propose a two-stage synergistic compensation method. It flattens the gradient along the MSC opening axis in the first stage and nulls the noise along the SERF sensitivity axis at the second stage. The feedback-sensor positions are optimized by an NSGA-II based multiobjective algorithm, enhancing the noise suppression at each stage while preserving cardiac signals and avoids complex decoupling calculations. Experiments show that both the noise amplitude and spatial gradient on the measurement panel are reduced. In the presence of external disturbance, the magnetic field gradient decreased from 117.84 to 2.78 pT/m. The average sensitivity decreased from 238.19 fT/Hz1/2@1–40 Hz to 22.18 fT/Hz1/2@1–40 Hz, significantly improving the MCG signal quality.
- 21 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-10
Two-Stage Synergistic Compensation Method Regulates Disturbance Magnetic Field in MSC for High Quality MCG Measurement
Magnetocardiography (MCG) is critical for early diagnosis and treatment of cardiac diseases. Arrayed SERF atomic magnetometers deliver high-quality MCG in a near-zero field provided by a magnetic shielding cylinder (MSC) with active magnetic compensation (AMC). However, the magnetic noise within the MSC is dynamic and gradient-distributed, making conventional single-stage uniform-field AMC inadequate. To overcome this, we propose a two-stage synergistic compensation method. It flattens the gradient along the MSC opening axis in the first stage and nulls the noise along the SERF sensitivity axis at the second stage. The feedback-sensor positions are optimized by an NSGA-II based multiobjective algorithm, enhancing the noise suppression at each stage while preserving cardiac signals and avoids complex decoupling calculations. Experiments show that both the noise amplitude and spatial gradient on the measurement panel are reduced. In the presence of external disturbance, the magnetic field gradient decreased from 117.84 to 2.78 pT/m. The average sensitivity decreased from 238.19 fT/Hz1/2@1–40 Hz to 22.18 fT/Hz1/2@1–40 Hz, significantly improving the MCG signal quality.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Analysis and Reconstruction of Magnetic Noise Model for Single-Ended Open Magnetic Shielding Cylinder
Accurately estimating and suppressing magnetic noise within magnetocardiography (MCG) devices is of great significance for improving the accuracy of MCG measurements. However, the calculation of magnetic noise inside a single-ended open magnetic shielding cylinder (MSC) lacks an accurate magnetic noise model. This paper analyzes and reconstructs the magnetic noise model (R-MN model) based on the variable-parameter magnetic loss separation model to address this issue. By incorporating appropriate penalty terms into the objective function, the variable-parameter magnetic loss separation model achieves high-precision loss separation utilizing the Artificial Hummingbird Algorithm. Compared with the conventional magnetic noise calculation method, the proposed R-MN model can reduce the root mean square error of noise prediction by 96.8%. The permalloy-nanocrystalline MSC composite structure designed based on the R-MN-model reduces the intrinsic average magnetic noise of the conventional MSC within the frequency range of 1-40 Hz from 11.77 fT/Hz¹ᐟ² to 4.41 fT/Hz¹ᐟ². This study provides theoretical foundations and technical support for designing low-noise, large-scale, and asymmetrically structured magnetic shielding devices.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Analysis and Reconstruction of Magnetic Noise Model for Single-Ended Open Magnetic Shielding Cylinder
Accurately estimating and suppressing magnetic noise within magnetocardiography (MCG) devices is of great significance for improving the accuracy of MCG measurements. However, the calculation of magnetic noise inside a single-ended open magnetic shielding cylinder (MSC) lacks an accurate magnetic noise model. This paper analyzes and reconstructs the magnetic noise model (R-MN model) based on the variable-parameter magnetic loss separation model to address this issue. By incorporating appropriate penalty terms into the objective function, the variable-parameter magnetic loss separation model achieves high-precision loss separation utilizing the Artificial Hummingbird Algorithm. Compared with the conventional magnetic noise calculation method, the proposed R-MN model can reduce the root mean square error of noise prediction by 96.8%. The permalloy-nanocrystalline MSC composite structure designed based on the R-MN-model reduces the intrinsic average magnetic noise of the conventional MSC within the frequency range of 1-40 Hz from 11.77 fT/Hz¹ᐟ² to 4.41 fT/Hz¹ᐟ². This study provides theoretical foundations and technical support for designing low-noise, large-scale, and asymmetrically structured magnetic shielding devices.
- 24 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Real-Time Disturbance Magnetic Field Observation Method Based on Multiple Sensors to Enhance the Directionality of Active Disturbance Suppression in MCG Systems
Active magnetic compensation is commonly combined with passive magnetic shielding structures in magnetocardiography measurements to suppress environmental magnetic disturbances and improve the signal-to-noise ratio. Accurate measurement of the disturbance field in the target region is essential for control decisions. Active compensation systems that rely on a single reference sensor often suffer from inaccurate disturbance estimation and degradation of the target signal signal-to-noise ratio. In this work, a computationally efficient magnetic field observation method based on two-dimensional spherical harmonics is proposed. By exploiting the spatial correlation differences of signals, a Kalman filter is designed to suppress random noise and target signal components in the reference sensor while interpolating the disturbance field in the target region. Validation experiments were conducted on a prototype magnetocardiography system equipped with a barrel-shaped magnetic shielding structure. The results demonstrate that the proposed observation method can effectively guide the active compensation system to suppress disturbances in the target region, with the suppression rate improved from 43.05% using a single sensor to 84.14%. This disturbance observation approach provides valuable insights for the development of multi-channel active compensation systems and magnetocardiography devices operating without passive magnetic shielding.
- 24 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Real-Time Disturbance Magnetic Field Observation Method Based on Multiple Sensors to Enhance the Directionality of Active Disturbance Suppression in MCG Systems
Active magnetic compensation is commonly combined with passive magnetic shielding structures in magnetocardiography measurements to suppress environmental magnetic disturbances and improve the signal-to-noise ratio. Accurate measurement of the disturbance field in the target region is essential for control decisions. Active compensation systems that rely on a single reference sensor often suffer from inaccurate disturbance estimation and degradation of the target signal signal-to-noise ratio. In this work, a computationally efficient magnetic field observation method based on two-dimensional spherical harmonics is proposed. By exploiting the spatial correlation differences of signals, a Kalman filter is designed to suppress random noise and target signal components in the reference sensor while interpolating the disturbance field in the target region. Validation experiments were conducted on a prototype magnetocardiography system equipped with a barrel-shaped magnetic shielding structure. The results demonstrate that the proposed observation method can effectively guide the active compensation system to suppress disturbances in the target region, with the suppression rate improved from 43.05% using a single sensor to 84.14%. This disturbance observation approach provides valuable insights for the development of multi-channel active compensation systems and magnetocardiography devices operating without passive magnetic shielding.
- 29 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (2) , 3316-3327
High-Precision Nonlinear Spatial Gradient Disturbance Suppression Method for Magnetic Shielding Cylinder
High-power devices used in hospitals generate harmonic magnetic field disturbances inside magnetic shielding cylinders (MSCs). These disturbances exhibit axial-gradient spatial distributions, which substantially degrade the imaging quality of magnetocardiography (MCG). To address this issue, a high-precision nonlinear spatial gradient disturbance suppression method is proposed for single-open MSCs. First, a nonlinear gradient coil design is developed to generate variable magnetic field gradients, precisely matching the nonlinear gradient distribution induced by external magnetic disturbances in the MSC. Subsequently, the entire system is modeled, and a composite controller based on proportional-integral repetitive control-linear extended state observer (PIRC-LESO) is designed to enhance the suppression of magnetic field disturbances with harmonic characteristics. Finally, an active magnetic field disturbance suppression system was implemented to evaluate the effectiveness of the nonlinear spatial gradient disturbance suppression method. Experimental results demonstrate that the proposed method reduces the peak-to-peak magnetic field disturbance from 42.0 to 6.9 pT and significantly enhances the signal-to-noise ratio of the MCG signals.
- 29 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (2) , 3316-3327
High-Precision Nonlinear Spatial Gradient Disturbance Suppression Method for Magnetic Shielding Cylinder
High-power devices used in hospitals generate harmonic magnetic field disturbances inside magnetic shielding cylinders (MSCs). These disturbances exhibit axial-gradient spatial distributions, which substantially degrade the imaging quality of magnetocardiography (MCG). To address this issue, a high-precision nonlinear spatial gradient disturbance suppression method is proposed for single-open MSCs. First, a nonlinear gradient coil design is developed to generate variable magnetic field gradients, precisely matching the nonlinear gradient distribution induced by external magnetic disturbances in the MSC. Subsequently, the entire system is modeled, and a composite controller based on proportional-integral repetitive control-linear extended state observer (PIRC-LESO) is designed to enhance the suppression of magnetic field disturbances with harmonic characteristics. Finally, an active magnetic field disturbance suppression system was implemented to evaluate the effectiveness of the nonlinear spatial gradient disturbance suppression method. Experimental results demonstrate that the proposed method reduces the peak-to-peak magnetic field disturbance from 42.0 to 6.9 pT and significantly enhances the signal-to-noise ratio of the MCG signals.
- 29 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Design of Uniform Magnetic Field Coils With Array Characteristics Under Asymmetric Coupling Effect in Magnetocardiography Devices
Uniform magnetic field coils (UMFCs) are vital for generating a magnetic field environment that meets the magneto-cardiography (MCG) measurement requirements. However, designing UMFCs under the influence of asymmetric coupling within a single-ended magnetic shielding cylinder (SEMSC) is challenging. To address this issue, this article proposes a design method for a coil with array characteristics (CAC), in which the current of each coil unit (CU) is adaptively adjusted based on the coupling differences, thereby enabling the CAC to generate a highly uniform magnetic field within the SEMSC. First, an ana-lytical model of the array within the SEMSC is established. Subsequently, a two-stage particle swarm optimization (TS-PSO) algorithm is proposed to optimize the currents and turns of each CU, and the CAC path is planned based on a depth-first search (DFS) strategy. Simulation and experimental results demonstrate that the CAC achieves superior magnetic field uniformity within the SEMSC compared to other coils. Furthermore, magnetic field compensation experiments validate the effectiveness of CAC in improving MCG measurement quality, indicating that the aver-age power spectral density of magnetic field noise in the 1–40 Hz frequency range is reduced from 52.34 fT/Hz1/2 to 26.16 fT/Hz1/2. These results highlight the significant importance of this method in creating the magnetic environment for MCG measurements.
- 29 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Design of Uniform Magnetic Field Coils With Array Characteristics Under Asymmetric Coupling Effect in Magnetocardiography Devices
Uniform magnetic field coils (UMFCs) are vital for generating a magnetic field environment that meets the magneto-cardiography (MCG) measurement requirements. However, designing UMFCs under the influence of asymmetric coupling within a single-ended magnetic shielding cylinder (SEMSC) is challenging. To address this issue, this article proposes a design method for a coil with array characteristics (CAC), in which the current of each coil unit (CU) is adaptively adjusted based on the coupling differences, thereby enabling the CAC to generate a highly uniform magnetic field within the SEMSC. First, an ana-lytical model of the array within the SEMSC is established. Subsequently, a two-stage particle swarm optimization (TS-PSO) algorithm is proposed to optimize the currents and turns of each CU, and the CAC path is planned based on a depth-first search (DFS) strategy. Simulation and experimental results demonstrate that the CAC achieves superior magnetic field uniformity within the SEMSC compared to other coils. Furthermore, magnetic field compensation experiments validate the effectiveness of CAC in improving MCG measurement quality, indicating that the aver-age power spectral density of magnetic field noise in the 1–40 Hz frequency range is reduced from 52.34 fT/Hz1/2 to 26.16 fT/Hz1/2. These results highlight the significant importance of this method in creating the magnetic environment for MCG measurements.
- 14 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Design and Optimization Method of Hybrid Biplanar Coils for Suppressing Uniform and Gradient Residual Magnetic Field
To achieve a nearly zero-field environment in a magnetically shielded room (MSR), compensation for both uniform and gradient magnetic fields is crucial. However, conventional strategies employing six pairs of coils face challenges of complex construction and coupling effects with ferromagnetic boundaries. To address this issue, a design and optimization method of hybrid bi-planar coils for suppressing uniform and gradient residual magnetic field for the MSR is proposed. By applying the symmetry of uniform and gradient coils, this method can substantially improve the integration of the system. Meanwhile, the coupling effect between the magnetic shielding material and compensation field is effectively reduced by incorporating the influence of ferromagnetic coupling on the coil magnetic fields. Numerical simulations and experimental verifications demonstrate that the designed coils exhibit superior uniformity in both uniform and gradient magnetic fields, which can be applied to achieve a remarkable zero-magnetic environment during measurements. The sensors sensitivity is significantly improved, from 2596.0 fT/Hz1/2 to 121.4 fT/Hz1/2 at 1 Hz, and reduced magnetic field fluctuations, from 1269.6 pT to 52.8 pT.
- 14 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Design and Optimization Method of Hybrid Biplanar Coils for Suppressing Uniform and Gradient Residual Magnetic Field
To achieve a nearly zero-field environment in a magnetically shielded room (MSR), compensation for both uniform and gradient magnetic fields is crucial. However, conventional strategies employing six pairs of coils face challenges of complex construction and coupling effects with ferromagnetic boundaries. To address this issue, a design and optimization method of hybrid bi-planar coils for suppressing uniform and gradient residual magnetic field for the MSR is proposed. By applying the symmetry of uniform and gradient coils, this method can substantially improve the integration of the system. Meanwhile, the coupling effect between the magnetic shielding material and compensation field is effectively reduced by incorporating the influence of ferromagnetic coupling on the coil magnetic fields. Numerical simulations and experimental verifications demonstrate that the designed coils exhibit superior uniformity in both uniform and gradient magnetic fields, which can be applied to achieve a remarkable zero-magnetic environment during measurements. The sensors sensitivity is significantly improved, from 2596.0 fT/Hz1/2 to 121.4 fT/Hz1/2 at 1 Hz, and reduced magnetic field fluctuations, from 1269.6 pT to 52.8 pT.