Antibody identification using both automated solid‐phase red cell adherence assay and a tube polyethylene glycol antiglobulin method
- 29 July 2008
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 48 (8) , 1693-1698
Abstract
BACKGROUND: Because antibody identification is labor‐intensive, facilities with high volume and/or marginal technical support could benefit from partial automation.STUDY DESIGN AND METHODS: After a validation study of automated solid‐phase red cell (RBC) adherence assay (SPRCA; Galileo, Immucor) compared to tube polyethylene glycol antiglobulin antibody identification method (t‐PEG), we evaluated Galileo followed by select RBC panels by t‐PEG. Of 298 consecutive samples in which antibody identifications were performed in a 2‐month period, 160 samples were examined by both Galileo and t‐PEG.RESULTS: There were concordant results between Galileo and t‐PEG in 120 of 160 (75%) samples including cases with identical alloantibody identification (n = 99), panagglutinin (n = 9), and negative results (n = 12). Of the samples in which alloantibodies were identified, 99 of 108 (91.7%) were identical. In 9 samples with discrepant antibody identifications, 2 samples showed alloantibody specificity by Galileo (possible anti‐K and anti‐Jkb) but were negative by t‐PEG. These antibodies were identifiable by t‐PEG in subsequent samples. One sample showed anti‐E by Galileo, while t‐PEG revealed anti‐Fya and ‐E. Five samples showed alloantibody specificity by t‐PEG and nonspecific reactivity or panagglutinin by Galileo. These included samples with anti‐C (n = 2), anti‐E (n = 2), and anti‐Fya (n = 1). One sample showed anti‐E by t‐PEG but was negative by Galileo. Galileo found a panagglutinin in 23 samples and nonspecific reactivity in 22 samples, whereas t‐PEG found a panagglutinin in 12 samples but no nonspecific reactivity.CONCLUSIONS: Automated Galileo solid‐phase red cell adherence assay can be a useful adjunct for antibody identification, although it detects more nonspecific reactivity than does t‐PEG.Keywords
This publication has 10 references indexed in Scilit:
- Acute haemolytic transfusion reaction by Lea alloantibodyAmerican Journal of Hematology, 2006
- North American Pretransfusion Testing Practices, 2001–2004: Results From the College of American Pathologists Interlaboratory Comparison Program Survey Data, 2001–2004Archives of Pathology & Laboratory Medicine, 2005
- Optimizing pretransfusion antibody detection and identification:a parallel, blinded comparison of tube PEG,solid‐phase, and automated methodsTransfusion, 2001
- Delayed haemolytic transfusion reaction caused by anti-M antibody in a patient receiving interleukin-2 and interferon for metastatic renal cell cancerClinical and Laboratory Haematology, 1999
- Comparison of the performance of four microtube column agglutination systems in the detection of red cell alloantibodiesTransfusion, 1999
- Delayed haemolytic transfusion reaction due to anti‐M antibodyBritish Journal of Haematology, 1998
- Polyethylene Glycol: A New Potentiator of Red Blood Cell Antigen–Antibody ReactionsAmerican Journal of Clinical Pathology, 1987
- Anti‐M causing delayed hemolytic transfusion reactionTransfusion, 1983
- Haemolytic Transfusion Reaction Caused by Anti‐LeaVox Sanguinis, 1960
- Hemolytic Transfusion Reaction Due to Anti-LeaBlood, 1955