Comparison of cardiac output derived from FloTrac™/Vigileo™ and impedance cardiography during major abdominal surgery
Open Access
- 26 June 2013
- journal article
- research article
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 41 (4) , 1342-1349
Abstract
Objectives: Impedance cardiography (ICG) is a noninvasive technique that provides reasonably accurate measurements of cardiac output, but the usefulness of ICG in patients undergoing open abdominal surgery has not been validated. Methods: Cardiac output was measured while patients underwent open gastrectomy using an ICG monitor ( niccomo™; ICG-CO); the results were compared with those measured using a FloTrac™/Vigileo™ monitor (Flo-CO), which measures cardiac output by analysing the arterial waveform. Data collection commenced at the beginning of anaesthetic induction and continued until the patient was awake. Data were compared using the Bland–Altman analysis, and the clinical significance of the difference between the two methods was evaluated by calculating the percentage error (%). Results: Eleven patients were monitored during surgery. The bias of the Flo-CO and ICG-CO values was −0.45 l/min. The upper and lower limits of agreement were 0.96 l/min and −1.85 l/min, respectively. The percentage error was 28.5%. Electrocautery induced interference that transiently impaired the performance of the ICG monitor. Conclusions: ICG provided useful information in evaluating the cardiac output of patients during abdominal surgery.Keywords
This publication has 22 references indexed in Scilit:
- Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac outputJournal of Clinical Monitoring and Computing, 2012
- Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patientsIntensive Care Medicine, 2010
- Cardiac output derived from arterial pressure waveformCurrent Opinion in Anaesthesiology, 2009
- Cardiac output monitoringCurrent Opinion in Anaesthesiology, 2009
- RETRACTED ARTICLE: Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilutionIntensive Care Medicine, 2006
- Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and potential cardiovascular applicationsCurrent Opinion in Cardiology, 2004
- Increased risk associated with pulmonary artery catheterization in the medical intensive care unitJournal of Critical Care, 2003
- The technique of impedance cardiographyEuropean Heart Journal, 1997
- Multicenter trial of a new thoracic electrical bioimpedance device for cardiac output estimationCritical Care Medicine, 1994
- Intraoperative cardiac output monitoring: Comparison of impedance cardiography and thermodilutionJournal of Cardiothoracic and Vascular Anesthesia, 1994