CytoScan: Automated Detection of Technical Anomalies for Cytometry Quality Control
Open Access
- 6 July 2026
- journal article
- Published by Wiley in Cytometry Part A
- Vol. 109 (8) , 581-592
Abstract
Studies evaluating cellular phenotypes by cytometry techniques are increasingly facing analytical challenges due to the multitudes of samples and parameters that are evaluated concurrently. Spurious technical effects resulting from a lack of standardization can affect marker distributions and further complicate multi‐sample analyses. User‐friendly tools for exploratory data analysis to identify such technical effects in large datasets are lacking. To fill this gap, we present a novel R package, CytoScan, that evaluates inter‐measurement variation in cytometry datasets and allows for detecting anomalous measurements after data acquisition. CytoScan can detect two types of anomalies: files with limited similarity to others within a dataset (outliers) and files with limited similarity to previously acquired high‐quality reference data (novelties). Using simulations of skewed marker distributions and real‐life technical effects, we demonstrate that CytoScan can accurately detect such anomalies. CytoScan can be applied to large cytometry datasets on consumer‐grade hardware with informative visualizations, providing accessible quality control for more reliable analyses.Keywords
Funding Information
- Cancer Center Amsterdam
This publication has 22 references indexed in Scilit:
- CytoBatchFlagR : A Comprehensive Framework to Objectively Assess High‐Parameter Cytometry Data for Batch EffectsCytometry Part A, 2026
- Visual Quality Control With CytoMDS, a Bioconductor Package for Low Dimensional Representation of Cytometry Sample DistancesCytometry Part A, 2025
- CytoNorm 2.0: A flexible normalization framework for cytometry data without requiring dedicated controlsCytometry Part A, 2025
- A robust pipeline for high-content, high-throughput immunophenotyping reveals age- and genetics-dependent changes in blood leukocytesCell Reports Methods, 2023
- flowCut: An R package for automated removal of outlier events and flagging of files based on time versus fluorescence analysisCytometry Part A, 2022
- PeacoQC: Peak‐based selection of high quality cytometry dataCytometry Part A, 2021
- CytoNorm: A Normalization Algorithm for Cytometry DataCytometry Part A, 2019
- Automated Flow Cytometric MRD Assessment in Childhood Acute B‐ Lymphoblastic Leukemia Using Supervised Machine LearningCytometry Part A, 2019
- FlowSOM: Using self‐organizing maps for visualization and interpretation of cytometry dataCytometry Part A, 2015
- Per‐channel basis normalization methods for flow cytometry dataCytometry Part A, 2009