Tim R. Mocking
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tim R. Mocking has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Costa Bachas
Department of Hematology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
9 shared publications Angèle Kelder
6 shared publications- Jacqueline Cloos
Department of Hematology, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
6 shared publications - Arjan A. van de Loosdrecht
Amsterdam UMC location VUmc, Amsterdam, Netherlands
4 shared publications Gert J. Ossenkoppele
4 shared publications- Lok Lam Ngai
Department of Hematology, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
4 shared publications
Latest Publications
- Open Access
- 6 July 2026
- Published by Wiley in Cytometry Part A
- Vol. 109 (8) , 581-592
CytoScan: Automated Detection of Technical Anomalies for Cytometry Quality Control
Studies evaluating cellular phenotypes by cytometry techniques are increasingly facing analytical challenges due to the multitudes of samples and parameters that are evaluated concurrently. Spurious technical effects resulting from a lack of standardization can affect marker distributions and further complicate multi‐sample analyses. User‐friendly tools for exploratory data analysis to identify such technical effects in large datasets are lacking. To fill this gap, we present a novel R package, CytoScan, that evaluates inter‐measurement variation in cytometry datasets and allows for detecting anomalous measurements after data acquisition. CytoScan can detect two types of anomalies: files with limited similarity to others within a dataset (outliers) and files with limited similarity to previously acquired high‐quality reference data (novelties). Using simulations of skewed marker distributions and real‐life technical effects, we demonstrate that CytoScan can accurately detect such anomalies. CytoScan can be applied to large cytometry datasets on consumer‐grade hardware with informative visualizations, providing accessible quality control for more reliable analyses.
- 6 July 2026
- Published by Wiley in Cytometry Part A
- Vol. 109 (8) , 581-592
Open AccessCytoScan: Automated Detection of Technical Anomalies for Cytometry Quality Control
Studies evaluating cellular phenotypes by cytometry techniques are increasingly facing analytical challenges due to the multitudes of samples and parameters that are evaluated concurrently. Spurious technical effects resulting from a lack of standardization can affect marker distributions and further complicate multi‐sample analyses. User‐friendly tools for exploratory data analysis to identify such technical effects in large datasets are lacking. To fill this gap, we present a novel R package, CytoScan, that evaluates inter‐measurement variation in cytometry datasets and allows for detecting anomalous measurements after data acquisition. CytoScan can detect two types of anomalies: files with limited similarity to others within a dataset (outliers) and files with limited similarity to previously acquired high‐quality reference data (novelties). Using simulations of skewed marker distributions and real‐life technical effects, we demonstrate that CytoScan can accurately detect such anomalies. CytoScan can be applied to large cytometry datasets on consumer‐grade hardware with informative visualizations, providing accessible quality control for more reliable analyses.
- Open Access
CytoScan: Automated detection of technical anomalies for cytometry quality control
Studies evaluating cellular phenotypes by cytometry techniques are increasingly facing analytical challenges due to the multitudes of samples and parameters that are evaluated concurrently. Spurious technical effects resulting from a lack of standardization can affect marker distributions and further complicate multi-sample analyses. User-friendly tools for exploratory data analysis to identify such technical effects in large datasets are lacking. To fill this gap, we present a novel R package, CytoScan, that evaluates inter-measurement variation in cytometry datasets and allows for detecting anomalous measurements after data acquisition. CytoScan can detect two types of anomalies: files with limited similarity to others within a dataset (outliers) and files with limited similarity to previously acquired high-quality reference data (novelties). Using simulations of skewed marker distributions and real-life technical effects we demonstrate that CytoScan can accurately detect such anomalies. CytoScan can be applied to large cytometry datasets on consumer-grade hardware with informative visualizations, providing accessible quality-control for more reliable analyses.
Open AccessCytoScan: Automated detection of technical anomalies for cytometry quality control
Studies evaluating cellular phenotypes by cytometry techniques are increasingly facing analytical challenges due to the multitudes of samples and parameters that are evaluated concurrently. Spurious technical effects resulting from a lack of standardization can affect marker distributions and further complicate multi-sample analyses. User-friendly tools for exploratory data analysis to identify such technical effects in large datasets are lacking. To fill this gap, we present a novel R package, CytoScan, that evaluates inter-measurement variation in cytometry datasets and allows for detecting anomalous measurements after data acquisition. CytoScan can detect two types of anomalies: files with limited similarity to others within a dataset (outliers) and files with limited similarity to previously acquired high-quality reference data (novelties). Using simulations of skewed marker distributions and real-life technical effects we demonstrate that CytoScan can accurately detect such anomalies. CytoScan can be applied to large cytometry datasets on consumer-grade hardware with informative visualizations, providing accessible quality-control for more reliable analyses.
- Open Access
- 3 September 2025
- Published by Springer Nature in Leukemia
- Vol. 39 (10) , 2559-2562
Computational measurable residual disease assessment in acute myeloid leukemia: a retrospective validation in the HOVON-SAKK-132 trial
- 3 September 2025
- Published by Springer Nature in Leukemia
- Vol. 39 (10) , 2559-2562
Open AccessComputational measurable residual disease assessment in acute myeloid leukemia: a retrospective validation in the HOVON-SAKK-132 trial
- Open Access
- 21 May 2025
- Published by Wiley in HemaSphere
- Vol. 9 (5) , e70138
Applications of machine learning for immunophenotypic measurable residual disease assessment in acute myeloid leukemia
Immunophenotypic detection and quantification of residual leukemic cells by multiparameter flow cytometry is increasingly adopted in the clinical practice of acute myeloid leukemia (AML) to assess measurable residual disease (MRD). However, MRD levels quantified by manual gating analysis can differ based on differences in gating strategy between trained operators and clinical centers. Manual gating requires extensive training, is time‐consuming in daily practice, and faces a significant hurdle in analyzing data from next‐generation cytometry platforms. To address these challenges, several computational approaches involving machine learning and artificial intelligence algorithms have been proposed to automate or aid the assessment of MRD. However, the immunophenotypic variability between patients and the relatively low proportions of residual leukemic cells in AML challenge most algorithms and require innovative approaches. This review provides an overview of recent efforts in using computational methods for immunophenotypic AML‐MRD assessment. We first explain the technical and conceptual background of the different algorithms that have been explored. Next, we discuss their strengths and limitations in the disease‐specific context of AML. Finally, we highlight how computational approaches offer a unique opportunity to standardize or even outperform current manual gating analyses, and ultimately, improve the treatment of AML patients.
- 21 May 2025
- Published by Wiley in HemaSphere
- Vol. 9 (5) , e70138
Open AccessApplications of machine learning for immunophenotypic measurable residual disease assessment in acute myeloid leukemia
Immunophenotypic detection and quantification of residual leukemic cells by multiparameter flow cytometry is increasingly adopted in the clinical practice of acute myeloid leukemia (AML) to assess measurable residual disease (MRD). However, MRD levels quantified by manual gating analysis can differ based on differences in gating strategy between trained operators and clinical centers. Manual gating requires extensive training, is time‐consuming in daily practice, and faces a significant hurdle in analyzing data from next‐generation cytometry platforms. To address these challenges, several computational approaches involving machine learning and artificial intelligence algorithms have been proposed to automate or aid the assessment of MRD. However, the immunophenotypic variability between patients and the relatively low proportions of residual leukemic cells in AML challenge most algorithms and require innovative approaches. This review provides an overview of recent efforts in using computational methods for immunophenotypic AML‐MRD assessment. We first explain the technical and conceptual background of the different algorithms that have been explored. Next, we discuss their strengths and limitations in the disease‐specific context of AML. Finally, we highlight how computational approaches offer a unique opportunity to standardize or even outperform current manual gating analyses, and ultimately, improve the treatment of AML patients.
- Open Access
- 27 February 2025
- Published by Springer Nature in Leukemia
- Vol. 39 (4) , 972-975
CD34+CD38- leukemia stem cells predict clinical outcomes in acute myeloid leukemia patients treated non-intensively with hypomethylating agents
- 27 February 2025
- Published by Springer Nature in Leukemia
- Vol. 39 (4) , 972-975
Open AccessCD34+CD38- leukemia stem cells predict clinical outcomes in acute myeloid leukemia patients treated non-intensively with hypomethylating agents
- Open Access
- 19 December 2024
- Published by Springer Nature in Communications Medicine
- Vol. 4 (1) , 1-9
Computational assessment of measurable residual disease in acute myeloid leukemia using mixture models
Background The proportion of residual leukemic blasts after chemotherapy assessed by multiparameter flow cytometry, is an important prognostic factor for the risk of relapse and overall survival in acute myeloid leukemia (AML). This measurable residual disease (MRD) is used in clinical trials to stratify patients for more or less intensive consolidation therapy. However, an objective and reproducible analysis method to assess MRD status from flow cytometry data is lacking, yet is highly anticipated for broader implementation of MRD testing. Methods We propose a computational pipeline based on Gaussian mixture modeling that allows a fully automated assessment of MRD status while remaining completely interpretable for clinical diagnostic experts. Our pipeline requires limited training data, which makes it easily transferable to other medical centers and cytometry platforms. Results We identify all healthy and leukemic immature myeloid cells in with high concordance (Spearman’s Rho = 0.974) and classification performance (median F-score = 0.861) compared to manual analysis. Using control samples (n = 18), we calculate a computational MRD percentage with high concordance to expert gating (Spearman’s rho = 0.823) and predict MRD status in a cohort of 35 AML follow-up measurements with high accuracy (97%). Conclusions We demonstrate that our pipeline provides a powerful tool for fast (~3 s) and objective automated MRD assessment in AML.
- 19 December 2024
- Published by Springer Nature in Communications Medicine
- Vol. 4 (1) , 1-9
Open AccessComputational assessment of measurable residual disease in acute myeloid leukemia using mixture models
Background The proportion of residual leukemic blasts after chemotherapy assessed by multiparameter flow cytometry, is an important prognostic factor for the risk of relapse and overall survival in acute myeloid leukemia (AML). This measurable residual disease (MRD) is used in clinical trials to stratify patients for more or less intensive consolidation therapy. However, an objective and reproducible analysis method to assess MRD status from flow cytometry data is lacking, yet is highly anticipated for broader implementation of MRD testing. Methods We propose a computational pipeline based on Gaussian mixture modeling that allows a fully automated assessment of MRD status while remaining completely interpretable for clinical diagnostic experts. Our pipeline requires limited training data, which makes it easily transferable to other medical centers and cytometry platforms. Results We identify all healthy and leukemic immature myeloid cells in with high concordance (Spearman’s Rho = 0.974) and classification performance (median F-score = 0.861) compared to manual analysis. Using control samples (n = 18), we calculate a computational MRD percentage with high concordance to expert gating (Spearman’s rho = 0.823) and predict MRD status in a cohort of 35 AML follow-up measurements with high accuracy (97%). Conclusions We demonstrate that our pipeline provides a powerful tool for fast (~3 s) and objective automated MRD assessment in AML.
- Open Access
- 25 January 2024
- Published by Springer Nature in Leukemia
- Vol. 38 (3) , 630-639
Impact of hemodilution on flow cytometry based measurable residual disease assessment in acute myeloid leukemia
Measurable residual disease (MRD) measured in the bone marrow (BM) of acute myeloid leukemia (AML) patients after induction chemotherapy is an established prognostic factor. Hemodilution, stemming from peripheral blood (PB) mixing within BM during aspiration, can yield false-negative MRD results. We prospectively examined hemodilution by measuring MRD in BM aspirates obtained from three consecutive 2 mL pulls, along with PB samples. Our results demonstrated a significant decrease in MRD percentages between the first and second pulls (P = 0.025) and between the second and third pulls (P = 0.025), highlighting the impact of hemodilution. Initially, 39% of MRD levels (18/46 leukemia-associated immunophenotypes) exceeded the 0.1% cut-off, decreasing to 30% (14/46) in the third pull. Additionally, we assessed the performance of six published methods and parameters for distinguishing BM from PB samples, addressing or compensating for hemodilution. The most promising results relied on the percentages of CD16dim granulocytic population (scarce in BM) and CD117high mast cells (exclusive to BM). Our findings highlight the importance of estimating hemodilution in MRD assessment to qualify MRD results, particularly near the common 0.1% cut-off. To avoid false-negative results by hemodilution, it is essential to collect high-quality BM aspirations and preferably utilizing the initial pull for MRD testing.
- 25 January 2024
- Published by Springer Nature in Leukemia
- Vol. 38 (3) , 630-639
Open AccessImpact of hemodilution on flow cytometry based measurable residual disease assessment in acute myeloid leukemia
Measurable residual disease (MRD) measured in the bone marrow (BM) of acute myeloid leukemia (AML) patients after induction chemotherapy is an established prognostic factor. Hemodilution, stemming from peripheral blood (PB) mixing within BM during aspiration, can yield false-negative MRD results. We prospectively examined hemodilution by measuring MRD in BM aspirates obtained from three consecutive 2 mL pulls, along with PB samples. Our results demonstrated a significant decrease in MRD percentages between the first and second pulls (P = 0.025) and between the second and third pulls (P = 0.025), highlighting the impact of hemodilution. Initially, 39% of MRD levels (18/46 leukemia-associated immunophenotypes) exceeded the 0.1% cut-off, decreasing to 30% (14/46) in the third pull. Additionally, we assessed the performance of six published methods and parameters for distinguishing BM from PB samples, addressing or compensating for hemodilution. The most promising results relied on the percentages of CD16dim granulocytic population (scarce in BM) and CD117high mast cells (exclusive to BM). Our findings highlight the importance of estimating hemodilution in MRD assessment to qualify MRD results, particularly near the common 0.1% cut-off. To avoid false-negative results by hemodilution, it is essential to collect high-quality BM aspirations and preferably utilizing the initial pull for MRD testing.
- Open Access
- 6 July 2023
- Published by Wiley in Cytometry Part A
- Vol. 103 (10) , 818-829
Merging and imputation of flow cytometry data: A critical assessment
Although most modern techniques and analysis methods in multiparameter flow cytometry (MFC) allow for increased dimensionality for the characterization and quantification of cell populations, most MFC applications depend on flow cytometers measuring relatively small (F‐score between 0.53 and 0.87 when retrieving cell populations in different datasets. Performance remained inadequate for all methods, with only limited similarity at the cell level. In conclusion, the use of imputed MFC data should take such limitations into account and include independent validation of results to justify conclusions.
- 6 July 2023
- Published by Wiley in Cytometry Part A
- Vol. 103 (10) , 818-829
Open AccessMerging and imputation of flow cytometry data: A critical assessment
Although most modern techniques and analysis methods in multiparameter flow cytometry (MFC) allow for increased dimensionality for the characterization and quantification of cell populations, most MFC applications depend on flow cytometers measuring relatively small (F‐score between 0.53 and 0.87 when retrieving cell populations in different datasets. Performance remained inadequate for all methods, with only limited similarity at the cell level. In conclusion, the use of imputed MFC data should take such limitations into account and include independent validation of results to justify conclusions.