Design Optimization and Measurement Uncertainty of an Electromagnetic Level Sensor for Liquid Metal Reactors
- 14 March 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Abstract
This paper describes the design and operation of a prototype mutual inductance level sensor (MILS) and the development and validation of a finite-element analysis (FEA) model describing its behavior. The MILS was designed for use in liquid sodium up to temperatures of 650°C in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). Preliminary testing was performed in a room temperature test stand with aluminum acting as an analog for the sodium to better understand sensor performance and provide accurate code validation data. This experimental data, along with material properties found in literature, were used to validate a finite-element analysis model in ANSYS Maxwell. The validated ANSYS Maxwell model was used to examine the performance of the MILS in various environments and under various operating conditions. Simulations suggest the following: The MILS will perform adequately in liquid sodium and liquid lead at temperatures up to 650°C. The temperature dependence of electrical conductivity imposes a temperature dependence on the sensor that requires proper compensation. The MILS signal sensitivity is maximized when mutual inductance between sensor coils is maximized, and sensor geometry should be selected to account for this factor. The operating frequency of the MILS can be optimized and is dependent on process fluid material, operating temperature, and materials/geometry of sensor system. And finally the use of a stainless steel isolating thimble does not adversely affect the sensor signal. The primary sources of error for this MILS system are the accuracy of the calibration standard against which the sensor is calibrated, and the temperature dependence of the sensor. This work contains all the necessary details to recreate the FEA model and results. This model can be used to optimize the performance of a MILS in any operating environment to read any electrically conductive working fluid.Keywords
Funding Information
- U.S. Department of Energy Advanced Reactor Technology (ART) Program under Prime Contract between U.S. DOE and UChicago Argonne, LLC (DE-AC02-06CH11357)
This publication has 22 references indexed in Scilit:
- Accurate Thickness Measurement Using Eddy Current System Based on Novel Transformer ModelIEEE Transactions on Instrumentation and Measurement, 2022
- Design development and testing of mutual inductance type level sensor for molten lead-lithium alloyFusion Engineering and Design, 2021
- Electromagnetic Sensor for Detecting Wear Debris in Lubricating OilIEEE Transactions on Instrumentation and Measurement, 2020
- On the Development of a Robust Optical Fiber-Based Level SensorIEEE Sensors Journal, 2017
- Distributed temperature sensor testing in liquid sodiumNuclear Engineering and Design, 2017
- Development of mutual inductance type sodium level detectors for PFBRNuclear Engineering and Design, 2013
- A Low-Cost Noncontact Capacitance-Type Level Transducer for a Conducting LiquidIEEE Transactions on Instrumentation and Measurement, 2006
- Magnetic permeability of stainless steel for use in accelerator beam transport systems2002
- Extended Time Sampling for Accurate Optical Pulse Reflection Measurement in Level ControlIEEE Transactions on Instrumentation and Measurement, 1984
- Ultrasonic Level, Temperature, and Density SensorIEEE Transactions on Nuclear Science, 1982