Abstract
In this study, an immunosensor chip utilizing surface plasmon resonance (SPR) and cyclic voltammetry (CV) was fabricated for detecting carcinoembryonic antigen (CEA). Specifically, we applied in parallel an SPR instrument and a CV device to monitor the assembly of carcinoembryonic antibody (anti-CEA) on a protein A-conjugated surface and the subsequent ligand reaction. The immunosensor chips were constructed by various concentrations of protein A. To determine the surface characteristics of different self-assembly monolayers (SAMs), several quantitative and kinetic measurements were carried out. The extent of immobilization of anti-CEA and the immune response of anti-CEA antibody against CEA were measured using the SPR instrument and CV device. The terminal functional groups of protein A have different effects on the adsorption and covalent binding of immunoprotein depending on the steric hindrance. Through the parallel measurements, we demonstrate that SPR and CV are sensitive to measure the antigen–antibody binding capacity.Keywords
This publication has 15 references indexed in Scilit:
- Electrochemical probe for on‐chip type flow immunoassay: Immunoglobulin G labeled with ferrocenecarboaldehydeBiotechnology and Bioengineering, 2005
- Fabrication of DNA–protein conjugate layer on gold-substrate and its application to immunosensorColloids and Surfaces B: Biointerfaces, 2005
- Recent Developments, Characteristics, and Potential Applications of Electrochemical BiosensorsAnalytical Sciences, 2004
- Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of ProteinsScience, 2003
- Differential binding characteristics of protein G and protein A for Fc fragments of papain-digested mouse IgGImmunology Letters, 2003
- Biotinylated alginate immobilization matrix in the construction of an amperometric biosensor: application for the determination of glucoseAnalytica Chimica Acta, 2002
- Immunosensors—principles and applications to clinical chemistryClinica Chimica Acta, 2001
- Protein arrays and microarraysCurrent Opinion in Chemical Biology, 2001
- Evaluation of antibody immobilization methods for piezoelectric biosensor applicationBiosensors and Bioelectronics, 2000
- Surface plasmon resonance sensors: reviewSensors and Actuators B: Chemical, 1999