Novel immunoassay for carcinoembryonic antigen based on protein A-conjugated immunosensor chip by surface plasmon resonance and cyclic voltammetry
In this study, an immunosensor chip utilizing surface plasmon resonance (SPR) and cyclic voltammetry (CV) was fabricated for detecting carcinoembryonic antigen (CEA). Specifically, we applied in parallel an SPR instrument and a CV device to monitor the assembly of carcinoembryonic antibody (anti-CEA) on a protein A-conjugated surface and the subsequent ligand reaction. The immunosensor chips were constructed by various concentrations of protein A. To determine the surface characteristics of different self-assembly monolayers (SAMs), several quantitative and kinetic measurements were carried out. The extent of immobilization of anti-CEA and the immune response of anti-CEA antibody against CEA were measured using the SPR instrument and CV device. The terminal functional groups of protein A have different effects on the adsorption and covalent binding of immunoprotein depending on the steric hindrance. Through the parallel measurements, we demonstrate that SPR and CV are sensitive to measure the antigen–antibody binding capacity.
- 9 March 2006
- Published by Springer Nature in Bioprocess and Biosystems Engineering
- Vol. 28 (5) , 315-321
Novel immunoassay for carcinoembryonic antigen based on protein A-conjugated immunosensor chip by surface plasmon resonance and cyclic voltammetry
In this study, an immunosensor chip utilizing surface plasmon resonance (SPR) and cyclic voltammetry (CV) was fabricated for detecting carcinoembryonic antigen (CEA). Specifically, we applied in parallel an SPR instrument and a CV device to monitor the assembly of carcinoembryonic antibody (anti-CEA) on a protein A-conjugated surface and the subsequent ligand reaction. The immunosensor chips were constructed by various concentrations of protein A. To determine the surface characteristics of different self-assembly monolayers (SAMs), several quantitative and kinetic measurements were carried out. The extent of immobilization of anti-CEA and the immune response of anti-CEA antibody against CEA were measured using the SPR instrument and CV device. The terminal functional groups of protein A have different effects on the adsorption and covalent binding of immunoprotein depending on the steric hindrance. Through the parallel measurements, we demonstrate that SPR and CV are sensitive to measure the antigen–antibody binding capacity.
- 19 December 2005
- Published by Wiley in Electroanalysis
- Vol. 17 (24) , 2208-2216
Direct and Rapid Detection of Diphtherotoxin via Potentiometric Immunosensor Based on Nanoparticles Mixture and Polyvinyl Butyral as Matrixes
In this paper a novel potentiometric immunosensor for direct and rapid detection of diphtherotoxin (D‐Ag) has been developed by means of self‐assembly of monoclonal diphtheria antibody (D‐Ab) onto a platinum electrode based on nanoparticles mixture (containing gold nanoparticles and silica nanoparticles) and polyvinyl butyral (PVB) as matrixes. At first, D‐Ab was absorbed onto the surface of nanoparticles mixture, and then they were entrapped into polyvinyl butyral sol‐gel network on a platinum electrode. The detection is based on the change in the potentiometric response before and after the antigen‐antibody reaction in a phosphate buffer solution (pH 7.0). The immobilized D‐Ab exhibited direct potentiometric response toward D‐Ag. In comparison to the conventional applied methods, this strategy could allow antibodies immobilized with higher loading amount and better retained immunoactivity, as demonstrated by potentiometric response, cyclic voltammetry and electrochemical impedance spectroscopy of the immunosensor. The immunosensor with nanoparticles mixture exhibited much higher sensitivity, better reproducibility, and long‐term stability than that with gold nanoparticles or silica nanoparticles alone. The linear range was from 5.0×10−3 to 1.2 μg⋅mL−1 with a detection limit of 1.1×10−3 μg⋅mL−1. Up to 16 successive assay cycles with retentive sensitivity were achieved for the probes regenerated with in 0.2 mol⋅L−1 glycine‐hydrochloric acid (Gly‐HCl) buffer solution and 0.25 mol⋅L−1 NaCl. Moreover, the immunosensor with nanoparticles mixture was applied to evaluate a number of practical specimens with potentiometric results in acceptable agreement with those given by the ELISA method, implying a promising alternative approach for detecting diphtherotoxin in the clinical diagnosis.
- 19 December 2005
- Published by Wiley in Electroanalysis
- Vol. 17 (24) , 2208-2216
Direct and Rapid Detection of Diphtherotoxin via Potentiometric Immunosensor Based on Nanoparticles Mixture and Polyvinyl Butyral as Matrixes
In this paper a novel potentiometric immunosensor for direct and rapid detection of diphtherotoxin (D‐Ag) has been developed by means of self‐assembly of monoclonal diphtheria antibody (D‐Ab) onto a platinum electrode based on nanoparticles mixture (containing gold nanoparticles and silica nanoparticles) and polyvinyl butyral (PVB) as matrixes. At first, D‐Ab was absorbed onto the surface of nanoparticles mixture, and then they were entrapped into polyvinyl butyral sol‐gel network on a platinum electrode. The detection is based on the change in the potentiometric response before and after the antigen‐antibody reaction in a phosphate buffer solution (pH 7.0). The immobilized D‐Ab exhibited direct potentiometric response toward D‐Ag. In comparison to the conventional applied methods, this strategy could allow antibodies immobilized with higher loading amount and better retained immunoactivity, as demonstrated by potentiometric response, cyclic voltammetry and electrochemical impedance spectroscopy of the immunosensor. The immunosensor with nanoparticles mixture exhibited much higher sensitivity, better reproducibility, and long‐term stability than that with gold nanoparticles or silica nanoparticles alone. The linear range was from 5.0×10−3 to 1.2 μg⋅mL−1 with a detection limit of 1.1×10−3 μg⋅mL−1. Up to 16 successive assay cycles with retentive sensitivity were achieved for the probes regenerated with in 0.2 mol⋅L−1 glycine‐hydrochloric acid (Gly‐HCl) buffer solution and 0.25 mol⋅L−1 NaCl. Moreover, the immunosensor with nanoparticles mixture was applied to evaluate a number of practical specimens with potentiometric results in acceptable agreement with those given by the ELISA method, implying a promising alternative approach for detecting diphtherotoxin in the clinical diagnosis.
- 4 December 2004
- Published by Springer Nature in Bioprocess and Biosystems Engineering
- Vol. 27 (2) , 135-141
Construction of a novel immunoassay for the relationship between anxiety and the development of a primary immune response to adrenal cortical hormone
A novel potentiometric immunosensor for the detection of adrenal cortical hormones (ACH) has been developed by means of self-assembling immobilization of adrenal cortical hormone antibody (anti-ACH) on a gold electrode-modified gold nanoparticle (Au) and a thiol-containing sol–gel network. A cleaned gold electrode was first immersed in a (3-mercaptopropyl)-trimethoxysilane (MPS) sol–gel solution to assemble a silica sol–gel monolayer, then the silane units were polymerized into a 2D sol–gel network (2D network) by dipping into aqueous NaOH. The second silane layer was formed by immersion back into the MPS solution overnight, and then the gold nanoparticles (nanogold) were chemisorbed onto the thiol groups of the second silane layer. Finally, anti-ACH was adsorbed onto the surface of the gold nanoparticles. The modified process was characterized by electrochemical impedance spectroscopy (EIS). The detection is based on the change in the potentiometric response before and after the antigen–antibody reaction. Using nanogold and 3-MPS as substrates, potentiometric detection at room temperature resulted in a pseudolinear detection range of about 22–1,000 ng mL−1 with a detection limit of 5.2 ng mL−1. Subsequently, several serum samples obtained from medical students with different anxiety extents were analyzed comparing with the ELISA method, and the results demonstrated that the immunoassay meets the demands of psychological analyses.
- 4 December 2004
- Published by Springer Nature in Bioprocess and Biosystems Engineering
- Vol. 27 (2) , 135-141
Construction of a novel immunoassay for the relationship between anxiety and the development of a primary immune response to adrenal cortical hormone
A novel potentiometric immunosensor for the detection of adrenal cortical hormones (ACH) has been developed by means of self-assembling immobilization of adrenal cortical hormone antibody (anti-ACH) on a gold electrode-modified gold nanoparticle (Au) and a thiol-containing sol–gel network. A cleaned gold electrode was first immersed in a (3-mercaptopropyl)-trimethoxysilane (MPS) sol–gel solution to assemble a silica sol–gel monolayer, then the silane units were polymerized into a 2D sol–gel network (2D network) by dipping into aqueous NaOH. The second silane layer was formed by immersion back into the MPS solution overnight, and then the gold nanoparticles (nanogold) were chemisorbed onto the thiol groups of the second silane layer. Finally, anti-ACH was adsorbed onto the surface of the gold nanoparticles. The modified process was characterized by electrochemical impedance spectroscopy (EIS). The detection is based on the change in the potentiometric response before and after the antigen–antibody reaction. Using nanogold and 3-MPS as substrates, potentiometric detection at room temperature resulted in a pseudolinear detection range of about 22–1,000 ng mL−1 with a detection limit of 5.2 ng mL−1. Subsequently, several serum samples obtained from medical students with different anxiety extents were analyzed comparing with the ELISA method, and the results demonstrated that the immunoassay meets the demands of psychological analyses.