Objective: Cardiovascular magnetic resonance enables the quantification of functional and morphological parameters with an impact on therapeutical decision making. While quantitative assessment is established in 2D, novel 3D techniques lack a standardized approach. Multi-planar-reformatting functionality in available software relies on visual matching location and often lacks necessary functionalities for further post-processing. Therefore, the easy-to-use Reslice3Dto2D software tool was developed as part of another research project to fill this gap and is now introduced with this work. Results: The Reslice3Dto2D reformats 3D data at the exact location of a reference slice with a two-step-based interpolation in order to reflect in-plane discretization and through-plane slice thickness including a slice profile selection. The tool was successfully validated on an artificial dataset and tested on 119 subjects with different underlying pathologies. The exported reformatted data could be imported into three different post-processing software tools. The quantified image sharpness by the Frequency Domain Image Blur Measure was significantly decreased by around 40% on rectangular slice profiles with 7 mm slice thickness compared to 0 mm due to partial volume effects. Consequently, Reslice3Dto2D enables the quantification of 3D data with conventional post-processing tools as well as the comparison of 3D acquisitions with their established 2D version.Keywords
Funding Information
- Charité - Universitätsmedizin Berlin
This publication has 18 references indexed in Scilit:
- Clinical Validation of a 3-Dimensional Ultrafast Cardiac Magnetic Resonance Protocol Including Single Breath-Hold 3-Dimensional SequencesJACC: Cardiovascular Imaging, 2021
- Cardiac magnetic resonance using fused 3D cine and 4D flow sequences:Validation of ventricular and blood flow measurementsMagnetic Resonance Imaging, 2020
- SCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2020
- Motion-corrected 3D whole-heart water-fat high-resolution late gadolinium enhancement cardiovascular magnetic resonance imagingJournal of Cardiovascular Magnetic Resonance, 2020
- Free-running simultaneous myocardial T1/T2 mapping and cine imaging with 3D whole-heart coverage and isotropic spatial resolutionMagnetic Resonance Imaging, 2019
- 3D whole-heart phase sensitive inversion recovery CMR for simultaneous black-blood late gadolinium enhancement and bright-blood coronary CMR angiographyJournal of Cardiovascular Magnetic Resonance, 2016
- 3D Slicer as an image computing platform for the Quantitative Imaging NetworkMagnetic Resonance Imaging, 2012
- Compensation of slice profile mismatch in combined spin‐ and gradient‐echo echo‐planar imaging pulse sequencesMagnetic Resonance in Medicine, 2011
- 4D XCAT phantom for multimodality imaging researchMedical Physics, 2010
- Estimation of the partial volume effect in MRIMedical Image Analysis, 2002