Darian Viezzer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Darian Viezzer has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Jeanette Schulz-Menger
Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Deutschland
6 shared publications - Clemens Ammann
Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
4 shared publications Steffen Lange
Faculty for Computer Sciences, Hochschule Darmstadt (University of Applied Sciences), Darmstadt, Germany
4 shared publicationsJeanette Schulz-Menger
3 shared publicationsJens Wetzl
Siemens Healthineers AG Forchheim Germany
3 shared publicationsMaximilian Fenski
Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, ECRC Experimental and Clinical Research Center, Berlin, Germany
3 shared publications
Latest Publications
- 1 February 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (1) , e240247
Assessing Cardiac 2D Flow MRI Reliability across Various Physiologic, Technical, and Observer Confounders in Healthy Traveling Volunteers
Comparing segmented and real-time two-dimensional flow cardiac MRI across four scanners in healthy volunteers revealed excellent repeatability for forward flow and moderate agreement for peak velocity despite physiologic and technical confounders.
- 1 February 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (1) , e240247
Assessing Cardiac 2D Flow MRI Reliability across Various Physiologic, Technical, and Observer Confounders in Healthy Traveling Volunteers
Comparing segmented and real-time two-dimensional flow cardiac MRI across four scanners in healthy volunteers revealed excellent repeatability for forward flow and moderate agreement for peak velocity despite physiologic and technical confounders.
- Open Access
- 4 October 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (4) , 1140-1154
Quantitative Confounder Analysis of Electrocardiogram Signals in Cardiac Magnetic Resonance at 1.5, 3 and 7 T—Assessing Standardized Electrode Positions and Sequence Types—Towards Quality Assurance
Background: The electrocardiogram (ECG) used for gating in cardiac MRI may be compromised by multiple confounders inside the scanner bore. Purpose: To quantify the influence of magnetic field strengths (1.5 T/3 T/7 T), standardized electrode positions, and imaging sequences on ECG signals used for gating. Study Type: Prospective. Population: Sixteen healthy volunteers (eight male; mean age 26.25 ± 7.67 years). Field Strength/Sequence: Balanced steady‐state free precession cine (1.5 T/3 T), fast low‐angle shot cine (7 T), and 4D flow (1.5 T/3 T/7 T) sequences. Assessment: ECG‐signals were recorded during breath‐hold and non‐breath‐hold short axis cine (sax‐bh and sax‐nbh, respectively) and 4D flow scans at 1.5 T/3 T/7 T. All scans were repeated with 4 standardized electrode positionings (pos1–4) at each field strength. Pos1/2 were vendor‐recommended positionings for 1.5 T/3 T/7 T scans, respectively, whereas pos3/4 were alternative positionings recommended in previous studies. Similarity between confounded ECG‐signals and unconfounded baseline ECG‐signals was assessed by QRS‐feature correlation. Cine image quality (IQ) was assessed by 3 readers (with 6, 10, and 22 years experience) on a four‐point Likert scale. Statistical Tests: Linear mixed models with type III tests of fixed effects (overall) and t tests with adjusted degrees of freedom (pairwise subgroup‐comparisons) at significance level p < 0.05. Results: Increasing field strength resulted in significantly decreasing similarity to baseline measurements, with r values (provided with 95% confidence interval) of 1.5 T: 97% (92.6–101.3); 3 T: 91.4% (87.1–95.8); 7 T: 50.4% (46–54.9) and lower IQ: 1.5 T: 2.33 (2.12–2.55); 3 T: 1.96 (1.75–2.17); 7 T: 0.91 (0.7–1.12). Vendor‐specified electrode positions pos1: 91.8% (87.2–96.5), pos2: 88.3% (83.7–92.9) showed significantly higher correlation with baseline measurements than alternative positions pos3: 67.5% (62.9–72.1) and pos4: 70.8% (66.2–75.4). The evaluated standardized sequences showed similar amounts of electrocardiogram distortion, with r values of: sax‐bh: 77.3% (73–81.7); 4D: 79.3% (75–83.7), p = 0.54; sax‐nbh: 82.1% (77.8–86.5), p = 0.31, but the difference between sax‐bh and sax‐nbh: 4.8% (2.88–6.72) was significant. Data Conclusion: Increasing field strength leads to significant ECG signal distortions. Vendor‐specified positions 1/2 resulted in less distorted ECG signals than alternative positions 3/4 recommended in previous publications. Level of Evidence: 2. Technical Efficacy: Stage 5.
- 4 October 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (4) , 1140-1154
Open AccessQuantitative Confounder Analysis of Electrocardiogram Signals in Cardiac Magnetic Resonance at 1.5, 3 and 7 T—Assessing Standardized Electrode Positions and Sequence Types—Towards Quality Assurance
Background: The electrocardiogram (ECG) used for gating in cardiac MRI may be compromised by multiple confounders inside the scanner bore. Purpose: To quantify the influence of magnetic field strengths (1.5 T/3 T/7 T), standardized electrode positions, and imaging sequences on ECG signals used for gating. Study Type: Prospective. Population: Sixteen healthy volunteers (eight male; mean age 26.25 ± 7.67 years). Field Strength/Sequence: Balanced steady‐state free precession cine (1.5 T/3 T), fast low‐angle shot cine (7 T), and 4D flow (1.5 T/3 T/7 T) sequences. Assessment: ECG‐signals were recorded during breath‐hold and non‐breath‐hold short axis cine (sax‐bh and sax‐nbh, respectively) and 4D flow scans at 1.5 T/3 T/7 T. All scans were repeated with 4 standardized electrode positionings (pos1–4) at each field strength. Pos1/2 were vendor‐recommended positionings for 1.5 T/3 T/7 T scans, respectively, whereas pos3/4 were alternative positionings recommended in previous studies. Similarity between confounded ECG‐signals and unconfounded baseline ECG‐signals was assessed by QRS‐feature correlation. Cine image quality (IQ) was assessed by 3 readers (with 6, 10, and 22 years experience) on a four‐point Likert scale. Statistical Tests: Linear mixed models with type III tests of fixed effects (overall) and t tests with adjusted degrees of freedom (pairwise subgroup‐comparisons) at significance level p < 0.05. Results: Increasing field strength resulted in significantly decreasing similarity to baseline measurements, with r values (provided with 95% confidence interval) of 1.5 T: 97% (92.6–101.3); 3 T: 91.4% (87.1–95.8); 7 T: 50.4% (46–54.9) and lower IQ: 1.5 T: 2.33 (2.12–2.55); 3 T: 1.96 (1.75–2.17); 7 T: 0.91 (0.7–1.12). Vendor‐specified electrode positions pos1: 91.8% (87.2–96.5), pos2: 88.3% (83.7–92.9) showed significantly higher correlation with baseline measurements than alternative positions pos3: 67.5% (62.9–72.1) and pos4: 70.8% (66.2–75.4). The evaluated standardized sequences showed similar amounts of electrocardiogram distortion, with r values of: sax‐bh: 77.3% (73–81.7); 4D: 79.3% (75–83.7), p = 0.54; sax‐nbh: 82.1% (77.8–86.5), p = 0.31, but the difference between sax‐bh and sax‐nbh: 4.8% (2.88–6.72) was significant. Data Conclusion: Increasing field strength leads to significant ECG signal distortions. Vendor‐specified positions 1/2 resulted in less distorted ECG signals than alternative positions 3/4 recommended in previous publications. Level of Evidence: 2. Technical Efficacy: Stage 5.
- 1 April 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 7 (2) , e240181
Evaluating the Effect of Heart Rate on T2 Balanced Steady-State Free Precession Cardiac MRI Mapping
A T2 balanced steady-state free precession cardiac MRI mapping sequence with three R-R intervals underestimated myocardial T2 values as heart rate increased, but this dependence was mitigated by using longer resting periods.
- 1 April 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 7 (2) , e240181
Evaluating the Effect of Heart Rate on T2 Balanced Steady-State Free Precession Cardiac MRI Mapping
A T2 balanced steady-state free precession cardiac MRI mapping sequence with three R-R intervals underestimated myocardial T2 values as heart rate increased, but this dependence was mitigated by using longer resting periods.
- Open Access
- 17 September 2024
- Published by Springer Nature in BMC Research Notes
- Vol. 17 (1) , 1-8
Reslice3Dto2D: Introduction of a software tool to reformat 3D volumes into reference 2D slices in cardiovascular magnetic resonance imaging
Objective: Cardiovascular magnetic resonance enables the quantification of functional and morphological parameters with an impact on therapeutical decision making. While quantitative assessment is established in 2D, novel 3D techniques lack a standardized approach. Multi-planar-reformatting functionality in available software relies on visual matching location and often lacks necessary functionalities for further post-processing. Therefore, the easy-to-use Reslice3Dto2D software tool was developed as part of another research project to fill this gap and is now introduced with this work. Results: The Reslice3Dto2D reformats 3D data at the exact location of a reference slice with a two-step-based interpolation in order to reflect in-plane discretization and through-plane slice thickness including a slice profile selection. The tool was successfully validated on an artificial dataset and tested on 119 subjects with different underlying pathologies. The exported reformatted data could be imported into three different post-processing software tools. The quantified image sharpness by the Frequency Domain Image Blur Measure was significantly decreased by around 40% on rectangular slice profiles with 7 mm slice thickness compared to 0 mm due to partial volume effects. Consequently, Reslice3Dto2D enables the quantification of 3D data with conventional post-processing tools as well as the comparison of 3D acquisitions with their established 2D version.
- 17 September 2024
- Published by Springer Nature in BMC Research Notes
- Vol. 17 (1) , 1-8
Open AccessReslice3Dto2D: Introduction of a software tool to reformat 3D volumes into reference 2D slices in cardiovascular magnetic resonance imaging
Objective: Cardiovascular magnetic resonance enables the quantification of functional and morphological parameters with an impact on therapeutical decision making. While quantitative assessment is established in 2D, novel 3D techniques lack a standardized approach. Multi-planar-reformatting functionality in available software relies on visual matching location and often lacks necessary functionalities for further post-processing. Therefore, the easy-to-use Reslice3Dto2D software tool was developed as part of another research project to fill this gap and is now introduced with this work. Results: The Reslice3Dto2D reformats 3D data at the exact location of a reference slice with a two-step-based interpolation in order to reflect in-plane discretization and through-plane slice thickness including a slice profile selection. The tool was successfully validated on an artificial dataset and tested on 119 subjects with different underlying pathologies. The exported reformatted data could be imported into three different post-processing software tools. The quantified image sharpness by the Frequency Domain Image Blur Measure was significantly decreased by around 40% on rectangular slice profiles with 7 mm slice thickness compared to 0 mm due to partial volume effects. Consequently, Reslice3Dto2D enables the quantification of 3D data with conventional post-processing tools as well as the comparison of 3D acquisitions with their established 2D version.
- Open Access
- 14 March 2024
- Published by Elsevier in EBioMedicine
- Vol. 102, 105055
Post-hoc standardisation of parametric T1 maps in cardiovascular magnetic resonance imaging: a proof-of-concept
- 14 March 2024
- Published by Elsevier in EBioMedicine
- Vol. 102, 105055
Open AccessPost-hoc standardisation of parametric T1 maps in cardiovascular magnetic resonance imaging: a proof-of-concept
- Open Access
- 18 May 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 238, 107615
Lazy Luna: Extendible software for multilevel reader comparison in cardiovascular magnetic resonance imaging
- 18 May 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 238, 107615
Open AccessLazy Luna: Extendible software for multilevel reader comparison in cardiovascular magnetic resonance imaging
- Open Access
- 6 February 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-14
Introduction of a cascaded segmentation pipeline for parametric T1 mapping in cardiovascular magnetic resonance to improve segmentation performance
The manual and often time-consuming segmentation of the myocardium in cardiovascular magnetic resonance is increasingly automated using convolutional neural networks (CNNs). This study proposes a cascaded segmentation (CASEG) approach to improve automatic image segmentation quality. First, an object detection algorithm predicts a bounding box (BB) for the left ventricular myocardium whose 1.5 times enlargement defines the region of interest (ROI). Then, the ROI image section is fed into a U-Net based segmentation. Two CASEG variants were evaluated: one using the ROI cropped image solely (cropU) and the other using a 2-channel-image additionally containing the original BB image section (crinU). Both were compared to a classical U-Net segmentation (refU). All networks share the same hyperparameters and were tested on basal and midventricular slices of native and contrast enhanced (CE) MOLLI T1 maps. Dice Similarity Coefficient improved significantly (p < 0.05) in cropU and crinU compared to refU (81.06%, 81.22%, 72.79% for native and 80.70%, 79.18%, 71.41% for CE data), while no significant improvement (p < 0.05) was achieved in the mean absolute error of the T1 time (11.94 ms, 12.45 ms, 14.22 ms for native and 5.32 ms, 6.07 ms, 5.89 ms for CE data). In conclusion, CASEG provides an improved geometric concordance but needs further improvement in the quantitative outcome.
- 6 February 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-14
Open AccessIntroduction of a cascaded segmentation pipeline for parametric T1 mapping in cardiovascular magnetic resonance to improve segmentation performance
The manual and often time-consuming segmentation of the myocardium in cardiovascular magnetic resonance is increasingly automated using convolutional neural networks (CNNs). This study proposes a cascaded segmentation (CASEG) approach to improve automatic image segmentation quality. First, an object detection algorithm predicts a bounding box (BB) for the left ventricular myocardium whose 1.5 times enlargement defines the region of interest (ROI). Then, the ROI image section is fed into a U-Net based segmentation. Two CASEG variants were evaluated: one using the ROI cropped image solely (cropU) and the other using a 2-channel-image additionally containing the original BB image section (crinU). Both were compared to a classical U-Net segmentation (refU). All networks share the same hyperparameters and were tested on basal and midventricular slices of native and contrast enhanced (CE) MOLLI T1 maps. Dice Similarity Coefficient improved significantly (p < 0.05) in cropU and crinU compared to refU (81.06%, 81.22%, 72.79% for native and 80.70%, 79.18%, 71.41% for CE data), while no significant improvement (p < 0.05) was achieved in the mean absolute error of the T1 time (11.94 ms, 12.45 ms, 14.22 ms for native and 5.32 ms, 6.07 ms, 5.89 ms for CE data). In conclusion, CASEG provides an improved geometric concordance but needs further improvement in the quantitative outcome.
- Open Access
- 23 November 2021
- Published by CERN in Open Research Europe
- Vol. 1, 80
An agenda-setting paper on data sharing platforms: euCanSHare workshop
Various data sharing platforms are being developed to enhance the sharing of cohort data by addressing the fragmented state of data storage and access systems. However, policy challenges in several domains remain unresolved. The euCanSHare workshop was organized to identify and discuss these challenges and to set the future research agenda. Concerns over the multiplicity and long-term sustainability of platforms, lack of resources, access of commercial parties to medical data, credit and recognition mechanisms in academia and the organization of data access committees are outlined. Within these areas, solutions need to be devised to ensure an optimal functioning of platforms.
- 23 November 2021
- Published by CERN in Open Research Europe
- Vol. 1, 80
Open AccessAn agenda-setting paper on data sharing platforms: euCanSHare workshop
Various data sharing platforms are being developed to enhance the sharing of cohort data by addressing the fragmented state of data storage and access systems. However, policy challenges in several domains remain unresolved. The euCanSHare workshop was organized to identify and discuss these challenges and to set the future research agenda. Concerns over the multiplicity and long-term sustainability of platforms, lack of resources, access of commercial parties to medical data, credit and recognition mechanisms in academia and the organization of data access committees are outlined. Within these areas, solutions need to be devised to ensure an optimal functioning of platforms.
- Open Access
- 19 July 2021
- Published by CERN in Open Research Europe
- Vol. 1, 80
An agenda-setting paper on data sharing platforms: euCanSHare workshop
Various data sharing platforms are being developed to enhance the sharing of cohort data by addressing the fragmented state of data storage and access systems. However, policy challenges in several domains remain unresolved. The euCanSHare workshop was organized to identify and discuss these challenges and to set the future research agenda. Concerns over the multiplicity and long-term sustainability of platforms, lack of resources, access of commercial parties to medical data, credit and recognition mechanisms in academia and the organization of data access committees are outlined. Within these areas, solutions need to be devised to ensure an optimal functioning of platforms.
- 19 July 2021
- Published by CERN in Open Research Europe
- Vol. 1, 80
Open AccessAn agenda-setting paper on data sharing platforms: euCanSHare workshop
Various data sharing platforms are being developed to enhance the sharing of cohort data by addressing the fragmented state of data storage and access systems. However, policy challenges in several domains remain unresolved. The euCanSHare workshop was organized to identify and discuss these challenges and to set the future research agenda. Concerns over the multiplicity and long-term sustainability of platforms, lack of resources, access of commercial parties to medical data, credit and recognition mechanisms in academia and the organization of data access committees are outlined. Within these areas, solutions need to be devised to ensure an optimal functioning of platforms.