The Partially Concrete Filled Steel Tube (PCFST) structure has gradually been applied to bridges as the main load carrying components in recent years, owing to the advantages of light weight and high stability. The failure mechanism and load carrying capacity of PCFST structure highly depends on the concrete filling ratio. For this purpose, the failure mechanism and parametric analysis of a single arched PCFST cable stayed bridge tower are investigated by using both refined solid element simulation and quasi-static experiment. The results shows that the PCFST arched tower experiences asymmetrical instability failure subjected to quarter span symmetrical loading, and the plastic hinges appears firstly at the tower arch closely above the tower columns, and then the bottom of the tower columns, forming a rotating mechanism leading to the instability failure. Filling concrete or not will result in two opposite deforming propagations of the plastic hinges, and when the concrete filling length exceeds the length of plastic hinge, the initial rigidity and ultimate load carrying capacity of the PCFST structure will sharply increase. Finally, according to the results of the extended parametric analysis based on the real size simulation, an improved initial stress reduction coefficient of PCFST structure is then suggested.Keywords
Funding Information
- Project of National Natural Science Foundation of China
- Fujian Science and Technology Plan Industry-University Cooperation Project
- National Key Research and Development Program of China
This publication has 33 references indexed in Scilit:
- Axial strength of concrete-filled double skin steel tubular (CFDST) columns with preload on steel tubesThin-Walled Structures, 2012
- Effect of Filled-Concrete Height on Ultimate Strength and Ductility of Steel Tubular Bridge Pier with Partial Filled-ConcreteAdvanced Materials Research, 2011
- Finite element modeling of hollow and concrete-filled fiber composite tubes in flexure: Optimization of partial filling and a design method for polesEngineering Structures, 2008
- A numerical investigation on the behaviour of concrete-filled steel tubular columns under initial stressesJournal of Constructional Steel Research, 2007
- A three-dimensional slope stability problem in clayCanadian Geotechnical Journal, 2006
- Seismic demand predictions of concrete-filled steel box columnsEngineering Structures, 2003
- New Structural Forms for Steel/Concrete Composite BridgesStructural Engineering International, 2000
- Behaviour of partially concrete-filled steel bridge piers under cyclic and dynamic loadingJournal of Constructional Steel Research, 1997
- ANALYTICAL STUDY ON ULTIMATE STRENGTH AND DEFORMATION OF PARTIALLY CONCRETE-FILLED STEEL BEAM-COLUMNS OF BOX SECTIONSDoboku Gakkai Ronbunshu, 1995
- Strength analysis of concrete-filled thin-walled steel box columnsJournal of Constructional Steel Research, 1994