Assessment of photovoltaic generation penetration effect on the maximum loadability of the system
- 1 March 2024
- journal article
- research article
- Published by IOP Publishing in Engineering Research Express
- Vol. 6 (1) , 015312
Abstract
This paper proposed a method to investigate the effect of increasing PV penetration on the voltage stability of an IEEE 14-bus test system considering maximum PV penetration and system loadability limit. The critical bus of the test system has been decided based on nose curve analysis. The solar PV system is deployed with the most critical bus of the system. The effect of increasing PV penetration on the improvement in the loading capacity of various power system components like transmission lines, transmission line transformers, and generators is investigated over the adopted test system. Based on solar PV penetration up to 100 MW, the maximum loadability limit of the IEEE 14-bus test system increases, as shown by the results. Bus 14 is found to be the most severe bus of the test system using the continuation power flow (CPF) method. However, in some cases, overloading situations develop after a certain limit of PV penetration in the power system. In this condition, the overloading of the power system equipment is improved by the use of a Static Synchronous Compensator (STATCOM) at bus number 14, a double circuit line in the critical line (9–14), and Static Synchronous Series Compensator (SSSC) in the most severe line (9–14) in the system. The maximum loadability of the system gets maximum enhanced from 4.0349 p.u. to 4.5602 p.u. under simultaneous use of solar PV generation, SSSC, and STATCOM at the most critical bus and in most severe line of the system. As evidence, the enhancement in maximum loadability of the system found using the proposed method has been also compared with the existing research. The maximum system loadability has been also enhanced under normal and (N-1) contingency conditions by the use of PV penetration in the system. PSAT/MATLAB software is used for simulation and maximum loadability has been investigated by continuation power flow (CPF) method.Keywords
This publication has 26 references indexed in Scilit:
- Application of Newton-based load flow methods for determining steady-state condition of well and ill-conditioned power systems: A reviewInternational Journal of Electrical Power & Energy Systems, 2019
- The dynamic relationship of renewable and nonrenewable energy consumption with carbon emission: A global study with the application of heterogeneous panel estimationsRenewable Energy, 2019
- LVRT capability enhancement of DFIG-based wind farms by using capacitive DC reactor-type fault current limiterInternational Journal of Electrical Power & Energy Systems, 2018
- Analytical approach to assess the loadability of unbalanced distribution grid with rooftop PV unitsApplied Energy, 2018
- Solar energy: Potential and future prospectsRenewable and Sustainable Energy Reviews, 2018
- Steady state analysis of wind-driven self-excited reluctance generator for isolated applicationsRenewable Energy, 2017
- Two-stage voltage control of subtransmission networks with high penetration of wind powerControl Engineering Practice, 2017
- Integration of PV and BES units in commercial distribution systems considering energy loss and voltage stabilityApplied Energy, 2014
- Optimum network reconfiguration based on maximization of system loadability using continuation power flow theoremInternational Journal of Electrical Power & Energy Systems, 2014
- Optimal hybrid PV/WT/FC sizing and distribution system reconfiguration using multi-objective artificial bee colony (MOABC) algorithmSolar Energy, 2012