Behavior of peptides and computer‐assisted optimization of peptides separations in a normal‐phase thin‐layer chromatography system with and without the addition of ionic liquid in the eluent
- 6 September 2004
- journal article
- research article
- Published by Wiley in Biomedical Chromatography
- Vol. 19 (1) , 1-8
Abstract
The addition of an ionic liquid into the mobile phase appeared to be useful in optimization of chromatographic separation of peptides. Different behavior of peptides in thin‐layer chromatography (TLC) was observed after addition of 1‐ethyl‐3‐methylimidazolium tetrafluoroborate to the eluent in comparison to the system without the ionic liquid. Nonlinear dependence of the retention coefficient, RM, of peptides on the volume percentage of acetonitrile in the eluent was found in normal‐phase TLC with and without immidazolium tetrafluoroborate in the mobile phase. In general, RM increased with increasing concentration of acetonitrile. In TLC systems without the ionic liquid, RM can be described well with a quadratic function. On the other hand, in a TLC system with an ionic liquid as the additive to the mobile phase, the retention behavior is better described with a third‐degree polynomial function. The potential usefulness of ionic liquids for optimization of separation of peptides was demonstrated. Optimization of the separation conditions was supported by a commercially available computer program. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 15 references indexed in Scilit:
- Suppression of deleterious effects of free silanols in liquid chromatography by imidazolium tetrafluoroborate ionic liquidsJournal of Chromatography A, 2004
- Electrospray ionization mass spectrometry of ionic liquids and determination of their solubility in waterAnalytical and Bioanalytical Chemistry, 2003
- Effect of 1-alkyl-3-methylimidazolium-based ionic liquids as the eluent on the separation of ephedrines by liquid chromatographyJournal of Chromatography A, 2003
- Effect of Ionic Liquids as Mobile Phase Additives on Retention of Catecholamines in Reversed-Phase High-Performance Liquid ChromatographyAnalytical Letters, 2003
- Characterisation of reversed-phase stationary phases for the liquid chromatographic analysis of basic pharmaceuticals by thermodynamic dataJournal of Chromatography A, 2002
- Quantitative relationship between the retention of peptides on a reversed-phase alumina support and their physicochemical parametersJournal of Chromatography A, 2002
- Imaging of thin-layer chromatograms using matrix-assisted laser desorption/ionization mass spectrometryAnalytical Chemistry, 1995
- Thin-Layer Chromatography Combined with Matrix-Assisted Laser Desorption/Ionization Mass SpectrometryAnalytical Chemistry, 1995
- Bare silica, dynamically modified with long-chain quaternary ammonium ions — the technique of choice for more reproducible selectivity in reversed-phase high-performance liquid chromatographyJournal of Chromatography A, 1991
- Surface silanols in silica-bonded hydrocarbonaceous stationary phasesJournal of Chromatography A, 1981