Red blood cell (RBC) suspensions in confined microflows: Pressure-flow relationship
- 23 August 2017
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 48 (1) , 49-54
Abstract
Microfluidic-based assays have become increasingly popular to explore microcirculation in vitro. In these experiments, blood is resuspended to a desired haematocrit level in a buffer solution, where frequent choices for preparing RBC suspensions comprise notably Dextran and physiological buffer. Yet, the rational for selecting one buffer versus another is often ill-defined and lacks detailed quantification, including ensuing changes in RBC flow characteristics. Here, we revisit RBC suspensions in microflows and attempt to quantify systematically some of the differences emanating between buffers. We measure bulk flow rate (Q) of RBC suspensions, using PBS- and Dextran-40, as a function of the applied pressure drop (ΔP) for two hematocrits (∼0% and 23%). Two distinct microfluidic designs of varying dimensions are employed: a straight channel larger than and a network array similar to the size of individual RBCs. Using the resulting pressure-flow curves, we extract the equivalent hydrodynamic resistances and estimate the relative viscosities. These efforts are a first step in rigorously quantifying the influence of the 'background' buffer on RBC flows within microfluidic devices and thereby underline the importance of purposefully selecting buffer suspensions for microfluidic in vitro assays.Keywords
This publication has 45 references indexed in Scilit:
- Microfluidics analysis of red blood cell membrane viscoelasticityLab on a Chip, 2010
- Deformability based cell margination—A simple microfluidic design for malaria-infected erythrocyte separationLab on a Chip, 2010
- Measurement of Individual Red Blood Cell Motions Under High Hematocrit Conditions Using a Confocal Micro-PTV SystemAnnals of Biomedical Engineering, 2009
- In vitro blood flow in a rectangular PDMS microchannel: experimental observations using a confocal micro-PIV systemBiomedical Microdevices, 2007
- In vitro confocal micro-PIV measurements of blood flow in a square microchannel: The effect of the haematocrit on instantaneous velocity profilesJournal of Biomechanics, 2007
- A microfluidic device for continuous, real time blood plasma separationLab on a Chip, 2006
- Microvascular blood viscosity in vivo and the endothelial surface layerAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- Velocity measurement of both red blood cells and plasma ofin vitroblood flow using high-speed micro PIV techniqueMeasurement Science and Technology, 2005
- Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)Analytical Chemistry, 1998
- Effects of Dextran-40 on Blood Viscosity in Experimental MacroglobulinaemiaNature, 1968