Dan Waisman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Dan Waisman has a total of 181 co-authors. Here are the top co-authors by number of shared publications:
Avi Rotschild
Neonatal Intensive Care Unit Lady Davis Carmel Medical Center Haifa Israel
19 shared publicationsAmir Landesberg
Faculty of Biomedical Engineering, Technion-IIT, Haifa, Israel
7 shared publicationsAnna Faingersh
Faculty of Biomedical Engineering, Technion-IIT, Haifa, Israel
6 shared publicationsCarmit Levy
1] Faculty of Biomedical Engineering, Technion-IIT, Haifa, Israel [2] Department of Neonatology, Mayer Children's Hospital, Haifa, Israel [3] Pneumedicare Ltd., Yokneam, Israel
6 shared publicationsHaim Bibi
Mayanei HaYeshuah Medical Center Bnei Brak Israel
6 shared publicationsVera Brod
Ischemia-Shock Research Laboratory, Department of Medicine, Carmel Medical Center, Faculty of Medicine, Technion, Haifa, Israel
5 shared publications
Latest Publications
- 9 December 2021
- Published by Wiley in Paediatric and Perinatal Epidemiology
- Vol. 36 (4) , 548-552
Group B Streptococcus real‐time PCR may potentially reduce intrapartum maternal antibiotic treatment
Background: Protocols for preventing early‐onset group B streptococcal (GBS) neonatal infection may result in unnecessary antibiotics administration. Real‐time polymerase chain reaction (PCR) can provide a result within 30–60 min and has been found to be specific and sensitive for defining intrapartum GBS status.Objective: To evaluate whether implementation of GBS fast real‐time PCR to all women who require GBS prophylaxis may reduce the use of maternal prophylactic antibiotics.Methods: This prospective cohort study included women admitted to a single delivery ward who required prophylactic antibiotics either due to a positive antepartum GBS culture screening performed at 35–37 weeks or due to an unknown GBS status with an intrapartum risk factor. All the women were tested by a double vaginal swab (real‐time PCR and culture) as soon as it became apparent, they required antibiotic prophylaxis and prior to its administration.Results: Between May 2019 and August 2020, 303 women met eligibility criteria and were enrolled, but four were excluded from the analysis due to failed culture or PCR tests. Of 299 women included in the study, 208 (69.5%) and 180 (60.2%) women, showed no evidence of GBS on intrapartum culture or PCR, respectively. Of 89 GBS antepartum carriers, 43 (48.3%) and 32 (35.9%) had negative intrapartum culture and PCR results, respectively. Of the 210 women with risk factors, 165 (78.5%) were culture negative and 148 (70.4%) had a negative PCR. Using intrapartum culture as the gold standard, intrapartum GBS real‐time PCR was found to have a sensitivity of 97.8% (95% confidence interval [CI] 92.3, 99.7) and a specificity of 85.6% (95% CI 80.1, 90.1).Conclusions: Compared with antepartum universal culture screening or intrapartum risk‐factor assessment, the need for maternal antibiotic treatment may be substantially reduced by implementation of intrapartum GBS real‐time PCR, without compromising the sensitivity of GBS detection.
- 9 December 2021
- Published by Wiley in Paediatric and Perinatal Epidemiology
- Vol. 36 (4) , 548-552
Group B Streptococcus real‐time PCR may potentially reduce intrapartum maternal antibiotic treatment
Background: Protocols for preventing early‐onset group B streptococcal (GBS) neonatal infection may result in unnecessary antibiotics administration. Real‐time polymerase chain reaction (PCR) can provide a result within 30–60 min and has been found to be specific and sensitive for defining intrapartum GBS status.Objective: To evaluate whether implementation of GBS fast real‐time PCR to all women who require GBS prophylaxis may reduce the use of maternal prophylactic antibiotics.Methods: This prospective cohort study included women admitted to a single delivery ward who required prophylactic antibiotics either due to a positive antepartum GBS culture screening performed at 35–37 weeks or due to an unknown GBS status with an intrapartum risk factor. All the women were tested by a double vaginal swab (real‐time PCR and culture) as soon as it became apparent, they required antibiotic prophylaxis and prior to its administration.Results: Between May 2019 and August 2020, 303 women met eligibility criteria and were enrolled, but four were excluded from the analysis due to failed culture or PCR tests. Of 299 women included in the study, 208 (69.5%) and 180 (60.2%) women, showed no evidence of GBS on intrapartum culture or PCR, respectively. Of 89 GBS antepartum carriers, 43 (48.3%) and 32 (35.9%) had negative intrapartum culture and PCR results, respectively. Of the 210 women with risk factors, 165 (78.5%) were culture negative and 148 (70.4%) had a negative PCR. Using intrapartum culture as the gold standard, intrapartum GBS real‐time PCR was found to have a sensitivity of 97.8% (95% confidence interval [CI] 92.3, 99.7) and a specificity of 85.6% (95% CI 80.1, 90.1).Conclusions: Compared with antepartum universal culture screening or intrapartum risk‐factor assessment, the need for maternal antibiotic treatment may be substantially reduced by implementation of intrapartum GBS real‐time PCR, without compromising the sensitivity of GBS detection.
- Open Access
- 16 November 2021
- Published by Wiley in Bioengineering & Translational Medicine
- Vol. 7 (2) , e10271
Ventilation‐induced epithelial injury drives biological onset of lung trauma in vitro and is mitigated with prophylactic anti‐inflammatory therapeutics
Mortality rates among patients suffering from acute respiratory failure remain perplexingly high despite the maintenance of blood oxygen homeostasis during ventilatory support. The biotrauma hypothesis advocates that mechanical forces from invasive ventilation trigger immunological mediators that spread systemically. Yet, how these forces elicit an immune response remains unclear. Here, a biomimetic in vitro three‐dimensional (3D) upper airways model allows to recapitulate lung injury and immune responses induced during invasive mechanical ventilation in neonates. Under such ventilatory support, flow‐induced stresses injure the bronchial epithelium of the intubated airways model and directly modulate epithelial cell inflammatory cytokine secretion associated with pulmonary injury. Fluorescence microscopy and biochemical analyses reveal site‐specific susceptibility to epithelial erosion in airways from jet‐flow impaction and are linked to increases in cell apoptosis and modulated secretions of cytokines IL‐6, ‐8, and ‐10. In an effort to mitigate the onset of biotrauma, prophylactic pharmacological treatment with Montelukast, a leukotriene receptor antagonist, reduces apoptosis and pro‐inflammatory signaling during invasive ventilation of the in vitro model. This 3D airway platform points to a previously overlooked origin of lung injury and showcases translational opportunities in preclinical pulmonary research toward protective therapies and improved protocols for patient care.
- 16 November 2021
- Published by Wiley in Bioengineering & Translational Medicine
- Vol. 7 (2) , e10271
Open AccessVentilation‐induced epithelial injury drives biological onset of lung trauma in vitro and is mitigated with prophylactic anti‐inflammatory therapeutics
Mortality rates among patients suffering from acute respiratory failure remain perplexingly high despite the maintenance of blood oxygen homeostasis during ventilatory support. The biotrauma hypothesis advocates that mechanical forces from invasive ventilation trigger immunological mediators that spread systemically. Yet, how these forces elicit an immune response remains unclear. Here, a biomimetic in vitro three‐dimensional (3D) upper airways model allows to recapitulate lung injury and immune responses induced during invasive mechanical ventilation in neonates. Under such ventilatory support, flow‐induced stresses injure the bronchial epithelium of the intubated airways model and directly modulate epithelial cell inflammatory cytokine secretion associated with pulmonary injury. Fluorescence microscopy and biochemical analyses reveal site‐specific susceptibility to epithelial erosion in airways from jet‐flow impaction and are linked to increases in cell apoptosis and modulated secretions of cytokines IL‐6, ‐8, and ‐10. In an effort to mitigate the onset of biotrauma, prophylactic pharmacological treatment with Montelukast, a leukotriene receptor antagonist, reduces apoptosis and pro‐inflammatory signaling during invasive ventilation of the in vitro model. This 3D airway platform points to a previously overlooked origin of lung injury and showcases translational opportunities in preclinical pulmonary research toward protective therapies and improved protocols for patient care.
- 4 August 2021
- Published by Wiley in Acta Paediatrica
- Vol. 110 (12) , 3269-3271
Neonatal resuscitation in the NICU; Challenges beyond NRP
- 4 August 2021
- Published by Wiley in Acta Paediatrica
- Vol. 110 (12) , 3269-3271
Neonatal resuscitation in the NICU; Challenges beyond NRP
- Open Access
Ventilation-induced epithelial injury drives biological onset of lung trauma in vitro and is mitigated with anti-inflammatory therapeutics
Mortality rates among patients suffering from acute respiratory failure remain perplexingly high despite maintenance of blood homeostasis. The biotrauma hypothesis advances that mechanical forces from invasive ventilation trigger immunological factors that spread systemically. Yet, how these forces elicit an immune response remains unclear. Here we show that flow-induced stresses under mechanical ventilation can injure the bronchial epithelium of ventilated in vitro upper airway models and directly modulate inflammatory cytokine secretion associated with pulmonary injury. We identify site-specific susceptibility to epithelial erosion in airways from jet-flow impaction and measure an increase in cell apoptosis and modulated secretions of cytokines IL-6, 8 and 10. We find that prophylactic pharmacological treatment with anti-inflammatory therapeutics reduces apoptosis and pro-inflammatory signaling during ventilation. Our 3D in vitro airway platform points to a previously overlooked origin of lung injury and showcases translational opportunities in preclinical pulmonary research towards protective therapies and improved protocols for patient care.
Open AccessVentilation-induced epithelial injury drives biological onset of lung trauma in vitro and is mitigated with anti-inflammatory therapeutics
Mortality rates among patients suffering from acute respiratory failure remain perplexingly high despite maintenance of blood homeostasis. The biotrauma hypothesis advances that mechanical forces from invasive ventilation trigger immunological factors that spread systemically. Yet, how these forces elicit an immune response remains unclear. Here we show that flow-induced stresses under mechanical ventilation can injure the bronchial epithelium of ventilated in vitro upper airway models and directly modulate inflammatory cytokine secretion associated with pulmonary injury. We identify site-specific susceptibility to epithelial erosion in airways from jet-flow impaction and measure an increase in cell apoptosis and modulated secretions of cytokines IL-6, 8 and 10. We find that prophylactic pharmacological treatment with anti-inflammatory therapeutics reduces apoptosis and pro-inflammatory signaling during ventilation. Our 3D in vitro airway platform points to a previously overlooked origin of lung injury and showcases translational opportunities in preclinical pulmonary research towards protective therapies and improved protocols for patient care.
- 19 November 2020
- Published by Wiley in Acta Paediatrica
- Vol. 110 (5) , 1475-1482
Using heated humidified high‐flow nasal cannulas for premature infants may result in an underestimated amount of water reaching the airways
Aim Condensation often occurs when providing humidified respiratory support. We examined conditions conducive to excess water formation in heated, humified, high‐flow nasal cannula (HHHFNC). Methods An HHHFNC device, at 35°C or 37°C, was attached with a nasal cannula to a reservoir and tested in five ambient conditions and flows. For Group A, tubing and collection bottle remained at room temperature (23°C). Group B, tubing and reservoir remained inside an incubator (31°C). Group C, tubing and reservoir remained at 33°C. In Group D the HHHFNC was set to 35°C, the reservoir remained at 33°C and the nasal cannula and tubing remained at 23°C. Group E, same as D, with HHHFNC at 37°C. Results The largest amounts of collected water were in groups A and E. Both had highest temperature differences. Median (range) was 4.9°C (4.1‐6.9) and 4.0°C, collecting 38.4 (26.4‐50.4) and 26.4 (19.2‐50.4) ml/24hs, respectively. Smallest amounts of water were seen with lower temperature differences as in Groups B, C, and D with 2.7 (1.9‐4.7), 1.6 (1.2‐2.1), and 2.0°C with 8.4 (0.0‐33.6), 2.4 (0.0‐14.4), and 9.6 (4.8‐16.8) ml/24hs, respectively. Conclusion HHHFNC devices may produce clinically significant amounts of water reaching the upper airways. This may be prevented with appropriate device setup.
- 19 November 2020
- Published by Wiley in Acta Paediatrica
- Vol. 110 (5) , 1475-1482
Using heated humidified high‐flow nasal cannulas for premature infants may result in an underestimated amount of water reaching the airways
Aim Condensation often occurs when providing humidified respiratory support. We examined conditions conducive to excess water formation in heated, humified, high‐flow nasal cannula (HHHFNC). Methods An HHHFNC device, at 35°C or 37°C, was attached with a nasal cannula to a reservoir and tested in five ambient conditions and flows. For Group A, tubing and collection bottle remained at room temperature (23°C). Group B, tubing and reservoir remained inside an incubator (31°C). Group C, tubing and reservoir remained at 33°C. In Group D the HHHFNC was set to 35°C, the reservoir remained at 33°C and the nasal cannula and tubing remained at 23°C. Group E, same as D, with HHHFNC at 37°C. Results The largest amounts of collected water were in groups A and E. Both had highest temperature differences. Median (range) was 4.9°C (4.1‐6.9) and 4.0°C, collecting 38.4 (26.4‐50.4) and 26.4 (19.2‐50.4) ml/24hs, respectively. Smallest amounts of water were seen with lower temperature differences as in Groups B, C, and D with 2.7 (1.9‐4.7), 1.6 (1.2‐2.1), and 2.0°C with 8.4 (0.0‐33.6), 2.4 (0.0‐14.4), and 9.6 (4.8‐16.8) ml/24hs, respectively. Conclusion HHHFNC devices may produce clinically significant amounts of water reaching the upper airways. This may be prevented with appropriate device setup.
- 11 December 2018
- Published by Springer Nature in Journal of Perinatology
- Vol. 39 (2) , 331-338
While waiting for a vaccine: opportunities for optimization of neonatal group B streptococcal (GBS) disease prevention in Israel
To quantify effects of different strategies for decreasing neonatal early onset GBS sepsis (EOGBS) in Israel. A risk allocation model for EOGBS among infants ≥ 35w was adapted to Israeli data. Effects of strategies for antepartum (APS) and intrapartum (IPS) screening, and intrapartum (IAP) and/or postpartum antibiotic prophylaxis (PAP) were calculated. Estimated EOGBS attack rates (AR) with APS in 90%, IAP in 90%, may reduce AR to 0.18/1000. A rapid intrapartum test would further decrease AR to 0.16/1000, while reducing IAP from 21.3 to 12.5% of women. For babies with risk factors and GBS+ who do not receive IAP, further risk reduction could be achieved by PAP. IAP remains the main intervention to decrease EOGBS. IAP and PAP together may reduce EOGBS present incidence by 40%. Combining rapid intrapartum screening with selective IAP and selective PAP for remaining gaps, would be the most efficient strategy.
- 11 December 2018
- Published by Springer Nature in Journal of Perinatology
- Vol. 39 (2) , 331-338
While waiting for a vaccine: opportunities for optimization of neonatal group B streptococcal (GBS) disease prevention in Israel
To quantify effects of different strategies for decreasing neonatal early onset GBS sepsis (EOGBS) in Israel. A risk allocation model for EOGBS among infants ≥ 35w was adapted to Israeli data. Effects of strategies for antepartum (APS) and intrapartum (IPS) screening, and intrapartum (IAP) and/or postpartum antibiotic prophylaxis (PAP) were calculated. Estimated EOGBS attack rates (AR) with APS in 90%, IAP in 90%, may reduce AR to 0.18/1000. A rapid intrapartum test would further decrease AR to 0.16/1000, while reducing IAP from 21.3 to 12.5% of women. For babies with risk factors and GBS+ who do not receive IAP, further risk reduction could be achieved by PAP. IAP remains the main intervention to decrease EOGBS. IAP and PAP together may reduce EOGBS present incidence by 40%. Combining rapid intrapartum screening with selective IAP and selective PAP for remaining gaps, would be the most efficient strategy.
- 23 August 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 48 (1) , 49-54
Red blood cell (RBC) suspensions in confined microflows: Pressure-flow relationship
Microfluidic-based assays have become increasingly popular to explore microcirculation in vitro. In these experiments, blood is resuspended to a desired haematocrit level in a buffer solution, where frequent choices for preparing RBC suspensions comprise notably Dextran and physiological buffer. Yet, the rational for selecting one buffer versus another is often ill-defined and lacks detailed quantification, including ensuing changes in RBC flow characteristics. Here, we revisit RBC suspensions in microflows and attempt to quantify systematically some of the differences emanating between buffers. We measure bulk flow rate (Q) of RBC suspensions, using PBS- and Dextran-40, as a function of the applied pressure drop (ΔP) for two hematocrits (∼0% and 23%). Two distinct microfluidic designs of varying dimensions are employed: a straight channel larger than and a network array similar to the size of individual RBCs. Using the resulting pressure-flow curves, we extract the equivalent hydrodynamic resistances and estimate the relative viscosities. These efforts are a first step in rigorously quantifying the influence of the 'background' buffer on RBC flows within microfluidic devices and thereby underline the importance of purposefully selecting buffer suspensions for microfluidic in vitro assays.
- 23 August 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 48 (1) , 49-54
Red blood cell (RBC) suspensions in confined microflows: Pressure-flow relationship
Microfluidic-based assays have become increasingly popular to explore microcirculation in vitro. In these experiments, blood is resuspended to a desired haematocrit level in a buffer solution, where frequent choices for preparing RBC suspensions comprise notably Dextran and physiological buffer. Yet, the rational for selecting one buffer versus another is often ill-defined and lacks detailed quantification, including ensuing changes in RBC flow characteristics. Here, we revisit RBC suspensions in microflows and attempt to quantify systematically some of the differences emanating between buffers. We measure bulk flow rate (Q) of RBC suspensions, using PBS- and Dextran-40, as a function of the applied pressure drop (ΔP) for two hematocrits (∼0% and 23%). Two distinct microfluidic designs of varying dimensions are employed: a straight channel larger than and a network array similar to the size of individual RBCs. Using the resulting pressure-flow curves, we extract the equivalent hydrodynamic resistances and estimate the relative viscosities. These efforts are a first step in rigorously quantifying the influence of the 'background' buffer on RBC flows within microfluidic devices and thereby underline the importance of purposefully selecting buffer suspensions for microfluidic in vitro assays.
- Open Access
- 1 January 2017
- Published by AIP Publishing in Biomicrofluidics
- Vol. 11 (1) , 014103
Red blood cell dynamics in biomimetic microfluidic networks of pulmonary alveolar capillaries
The pulmonary capillary networks (PCNs) embody organ-specific microvasculatures, where blood vessels form dense meshes that maximize the surface area available for gas exchange in the lungs. With characteristic capillary lengths and diameters similar to the size of red blood cells (RBCs), seminal descriptions coined the term "sheet flow" nearly half a century ago to differentiate PCNs from the usual notion of Poiseuille flow in long straight tubes. Here, we revisit in true-scale experiments the original “sheet flow” model and devise for the first time biomimetic microfluidic platforms of organ-specific PCN structures perfused with RBC suspensions at near-physiological hematocrit levels. By implementing RBC tracking velocimetry, our measurements reveal a wide range of heterogonous RBC pathways that coexist synchronously within the PCN; a phenomenon that persists across the broad range of pressure drops and capillary segment sizes investigated. Interestingly, in spite of the intrinsic complexity of the PCN structure and the heterogeneity in RBC dynamics observed at the microscale, the macroscale bulk flow rate versus pressure drop relationship retains its linearity, where the hydrodynamic resistance of the PCN is to a first order captured by the characteristic capillary segment size. To the best of our knowledge, our in vitro efforts constitute a first, yet significant, step in exploring systematically the transport dynamics of blood in morphologically inspired capillary networks.
- 1 January 2017
- Published by AIP Publishing in Biomicrofluidics
- Vol. 11 (1) , 014103
Open AccessRed blood cell dynamics in biomimetic microfluidic networks of pulmonary alveolar capillaries
The pulmonary capillary networks (PCNs) embody organ-specific microvasculatures, where blood vessels form dense meshes that maximize the surface area available for gas exchange in the lungs. With characteristic capillary lengths and diameters similar to the size of red blood cells (RBCs), seminal descriptions coined the term "sheet flow" nearly half a century ago to differentiate PCNs from the usual notion of Poiseuille flow in long straight tubes. Here, we revisit in true-scale experiments the original “sheet flow” model and devise for the first time biomimetic microfluidic platforms of organ-specific PCN structures perfused with RBC suspensions at near-physiological hematocrit levels. By implementing RBC tracking velocimetry, our measurements reveal a wide range of heterogonous RBC pathways that coexist synchronously within the PCN; a phenomenon that persists across the broad range of pressure drops and capillary segment sizes investigated. Interestingly, in spite of the intrinsic complexity of the PCN structure and the heterogeneity in RBC dynamics observed at the microscale, the macroscale bulk flow rate versus pressure drop relationship retains its linearity, where the hydrodynamic resistance of the PCN is to a first order captured by the characteristic capillary segment size. To the best of our knowledge, our in vitro efforts constitute a first, yet significant, step in exploring systematically the transport dynamics of blood in morphologically inspired capillary networks.
- 27 January 2016
- Published by Springer Nature in Journal of Perinatology
- Vol. 36 (2) , 157-159
Chest dynamics asymmetry facilitates earlier detection of pneumothorax
JPER is a multi-disciplinary journal that promotes the health of the preterm infant.
- 27 January 2016
- Published by Springer Nature in Journal of Perinatology
- Vol. 36 (2) , 157-159
Chest dynamics asymmetry facilitates earlier detection of pneumothorax
JPER is a multi-disciplinary journal that promotes the health of the preterm infant.
- 19 November 2015
- Published by Springer Nature in Journal of Perinatology
- Vol. 36 (2) , 116-120
Monitoring the respiratory rate by miniature motion sensors in premature infants: a comparative study
JPER is a multi-disciplinary journal that promotes the health of the preterm infant.
- 19 November 2015
- Published by Springer Nature in Journal of Perinatology
- Vol. 36 (2) , 116-120
Monitoring the respiratory rate by miniature motion sensors in premature infants: a comparative study
JPER is a multi-disciplinary journal that promotes the health of the preterm infant.