Lumenless Pacing Leads: Performance and Extraction in Pediatrics and Congenital Heart Disease
- 16 September 2014
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 38 (1) , 42-47
Abstract
Background: Pediatric and congenital heart disease (CHD) patients requiring permanent pacing present unique challenges, including need for long duration of implant, small size, and structural abnormalities. We report 6 years of experience with a novel 4.1‐Fr lumenless pacing lead (model 3830, Medtronic Inc., Minneapolis, MN, USA) in this population.Methods: Retrospective review of M3830 leads implanted at a pediatric center from 2005 to 2011. Data were compared to a population with a conventional pacing lead (model 1488, St. Jude Medical Inc., St. Paul, MN, USA).Results: A total of 193 patients with 198 model 3830 leads (125 atrial, 73 ventricular) were enrolled. CHD was present in 121 (63%). Age and weight at implant were 16.6 ± 8.5 years and 51.7 ± 23.5 kg, respectively. Length of follow‐up was 26 ± 19 months (range 0–73). At implant, mean sensing and capture thresholds were good and remained stable over time. There were no significant differences in electrical performance compared to 101 leads in the comparison group. Implant complications were rare. Follow‐up complications occurred in 4% of the M3830 leads and 16% of M1488 leads. Eleven M3830 leads required extraction. All were extracted without complications using only manual traction. There were three deaths in each group. One death in the M1488 group occurred during lead extraction. No other deaths were lead related.Conclusion: During up to 6 years of use in pediatric and CHD patients, the M3830 lead has demonstrated excellent efficacy, a low rate of complications, and straightforward extractability relative to traditional pacing leads.Keywords
This publication has 11 references indexed in Scilit:
- Performance of the Lumenless 4.1‐Fr Diameter Pacing Lead Implanted at Alternative Pacing Sites in Congenital Heart: A Chronic 5‐Year ComparisonPacing and Clinical Electrophysiology, 2010
- Selective-site pacing in paediatric patients: use of the SelectSecure System and risk of vein occlusionEP Europace, 2010
- Bipolar Lumenless Lead Performance in Children and Adults with Congenital Heart DiseaseCongenital Heart Disease, 2010
- Initial Experience of Pacing with a Lumenless Lead System in Patients with Congenital Heart DiseasePacing and Clinical Electrophysiology, 2009
- Selective-site pacing in paediatric patients: a new application of the Select Secure systemEP Europace, 2009
- Noncatheter‐Based Delivery of a Single‐Chamber Lumenless Pacing Lead in Small ChildrenPacing and Clinical Electrophysiology, 2007
- Implantation of SelectSecure? Leads in ChildrenPacing and Clinical Electrophysiology, 2007
- Pacemakers and implantable cardioverter-defibrillators in pediatric patientsHeart Rhythm, 2006
- Multi‐Center Clinical Experience with a Lumenless, Catheter‐Delivered, Bipolar, Permanent Pacemaker Lead: Implant Safety and Electrical PerformancePacing and Clinical Electrophysiology, 2006
- Endocardial Pacing After Fontan‐Type ProceduresPacing and Clinical Electrophysiology, 2005