Prediction of cell necrosis with sequential temperature mapping after radiofrequency ablation
Authors:
Open Access
- 23 July 2009
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 30 (3) , 631-639
Abstract
Purpose: To assess the feasibility of magnetic resonance (MR) thermometry after thermoablative therapy and to quantitatively evaluate the ability of two sequence types to predict cell necrosis.Methods: Twenty patients with hepatic tumors were treated by MR‐guided radiofrequency ablation. For each 10 patients, postinterventionally performed gradient echo and segmented echo planar imaging sequences were used to calculate temperature maps based on the proton resonance frequency shift method. Contrast‐enhanced images acquired 1 month after therapy were registered on the temperature maps and the necrotic, nonenhanced area was segmented and compared to the area with a displayed temperature above 60°C. Sensitivity and positive predictive value of the temperature map was calculated, using the follow‐up imaging as the gold standard.Results: Temperature mapping reached acceptable image quality in 45/47 cases. Sensitivity, ie, the rate of correctly detected coagulated tissue was 0.82 ± 0.08 for the gradient echo imaging (GRE) sequence and 0.81 ± 0.14 for the echo planar imaging (EPI) sequence. Positive predictive value, ie, the rate of voxel in the temperature map over 60°C that actually developed necrosis, was 0.90 ± 0.07 for the GRE sequence and 0.84 ± 0.11 for the EPI sequence.Conclusion: Sequential MR temperature mapping allows for the prediction of the coagulation zone with an acceptable sensitivity and positive predictive value using EPI and GRE sequences. J. Magn. Reson. Imaging 2009.Keywords
This publication has 32 references indexed in Scilit:
- Real time monitoring of radiofrequency ablation based on MR thermometry and thermal dose in the pig liver in vivoEuropean Radiology, 2007
- Real‐time monitoring of radiofrequency ablation of rabbit liver by respiratory‐gated quantitative temperature MRIJournal of Magnetic Resonance Imaging, 2006
- Quantitative magnetic resonance temperature mapping for real-time monitoring of radiofrequency ablation of the liver: an ex vivo studyEuropean Radiology, 2006
- In vivo porcine liver radiofrequency ablation with simultaneous MR temperature imagingJournal of Magnetic Resonance Imaging, 2006
- Magnetic Resonance Guidance of Thermal AblationTopics in Magnetic Resonance Imaging, 2005
- Image-guided Tumor Ablation: Standardization of Terminology and Reporting CriteriaJournal of Vascular and Interventional Radiology, 2005
- Experimental application of thermosensitive paramagnetic liposomes for monitoring magnetic resonance imaging guided thermal ablationMagnetic Resonance in Medicine, 2004
- Real‐time MR temperature mapping of rabbit liver in vivo during thermal ablationMagnetic Resonance in Medicine, 2003
- Sonographically Observed Echogenic Response During Intraoperative Radiofrequency Ablation of Cirrhotic LiversAmerican Journal of Roentgenology, 2002
- Thermal dose determination in cancer therapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1984