Energy performance of shallow borehole heat exchangers with multiphysics coupling in unsaturated soils
Authors:
- Frédéric KuznikFrédéric Kuznik
- Kheira BelhamidecheKBKheira Belhamideche
- Nadia LaredjNLNadia Laredj
- Mustapha MalikiMMMustapha Maliki
- Hanifi MissoumHMHanifi Missoum
Preprint
- 19 February 2026
- preprint
- Published by Elsevier in SSRN Electronic Journal
Abstract
Low geothermal energy involves harnessing heat from shallow underground sources. This technology uses a heat pump connected to a vertical ground heat exchanger. This study analyzes the performance of geothermal heat pump (GSHP) systems with U-shaped vertical borehole heat exchangers. A new mathematical model that considers thermo-hydro-vapor phase change coupling has been developed. This model accurately simulates the complex interactions between heat and water transfer and phase change processes in unsaturated, stratified soil under various climatic and geological conditions in the studied region. Finally, this study evaluates the effect of the distance between the two arms of the heat exchanger, the distance between two piles, and the number of piles on the performance of the GSHP system. The findings indicate that soil surface temperature affects water vapor concentration, affecting evaporation. Cooling in winter changes the vapor pressure, forming a condensation zone. The coefficient of performance (COP) increases with the spacing between the arms of the U-shaped exchanger. At a spacing of two meters, the COP reaches 4 and 6.01 in heating and cooling mode. Furthermore, the results indicate that the energy efficiency of the system under investigation is optimized when the spacing between two heat exchangers is set at 2.5 meters. The final results demonstrate that there is an optimal threshold of four piles, at which point the total energy extracted is 47.15% higher than with a single pile. Beyond this value, a decline in productivity is observed.Keywords
This publication has 25 references indexed in Scilit:
- Numerical investigation of vertical borehole heat exchanger heat transfer under coupled conditions of groundwater seepage and layered subsurfaceGeomechanics and Geophysics for Geo-Energy and Geo-Resources, 2023
- Performance analysis of helical ground heat exchangers with different configurationsApplied Thermal Engineering, 2019
- Numerical simulation of ground source heat pump systems considering unsaturated soil properties and groundwater flowApplied Thermal Engineering, 2018
- The effects of ground heat exchanger parameters changes on geothermal heat pump performance – A reviewApplied Thermal Engineering, 2018
- An improved analytical model for vertical borehole ground heat exchanger with multiple-layer substrates and groundwater flowApplied Energy, 2017
- Experimental and numerical study on the thermal performance of ground source heat pump with a set of designed buried pipesApplied Thermal Engineering, 2017
- Sensitivity analysis of a vertical geothermal heat pump systemApplied Energy, 2016
- A transient quasi-3D entire time scale line source model for the fluid and ground temperature prediction of vertical ground heat exchangers (GHEs)Applied Energy, 2016
- Geothermal heat pump systems: Status review and comparison with other heating optionsApplied Energy, 2013
- Three-dimensional coupled heat, moisture, and air transfer in a deformable unsaturated soilInternational Journal for Numerical Methods in Engineering, 1999