Hanifi Missoum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hanifi Missoum has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Nadia Laredj
Laboratory of Construction, Transport and Environmental Protection LCTPE, University Abdelhamid Ibn Badis, Mostaganem, Algeria
9 shared publications - Mustapha Maliki
Laboratory of Construction, Transport and Environmental Protection LCTPE, University Abdelhamid Ibn Badis, Mostaganem, Algeria
8 shared publications - Karim Bendani
LCTPE Laboratory, University Abdelhamid Ibn Badis of Mostaganem, Mostaganem, Algeria
2 shared publications Kheira Belhamideche
2 shared publications- Kheira Belhamideche
Laboratory of Construction, Transport and Environmental Protection LCTPE, University Abdelhamid Ibn Badis of Mostaganem, Mostaganem, Algeria
2 shared publications - Mahi Eddine Brahimi
Laboratory of Construction, Transport and Environmental Protection LCTPE, University Abdelhamid Ibn Badis, Mostaganem, Algeria
2 shared publications
Latest Publications
- Open Access
- 19 February 2026
- Published by Elsevier in SSRN Electronic Journal
Energy performance of shallow borehole heat exchangers with multiphysics coupling in unsaturated soils
Low geothermal energy involves harnessing heat from shallow underground sources. This technology uses a heat pump connected to a vertical ground heat exchanger. This study analyzes the performance of geothermal heat pump (GSHP) systems with U-shaped vertical borehole heat exchangers. A new mathematical model that considers thermo-hydro-vapor phase change coupling has been developed. This model accurately simulates the complex interactions between heat and water transfer and phase change processes in unsaturated, stratified soil under various climatic and geological conditions in the studied region. Finally, this study evaluates the effect of the distance between the two arms of the heat exchanger, the distance between two piles, and the number of piles on the performance of the GSHP system. The findings indicate that soil surface temperature affects water vapor concentration, affecting evaporation. Cooling in winter changes the vapor pressure, forming a condensation zone. The coefficient of performance (COP) increases with the spacing between the arms of the U-shaped exchanger. At a spacing of two meters, the COP reaches 4 and 6.01 in heating and cooling mode. Furthermore, the results indicate that the energy efficiency of the system under investigation is optimized when the spacing between two heat exchangers is set at 2.5 meters. The final results demonstrate that there is an optimal threshold of four piles, at which point the total energy extracted is 47.15% higher than with a single pile. Beyond this value, a decline in productivity is observed.
- 19 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEnergy performance of shallow borehole heat exchangers with multiphysics coupling in unsaturated soils
Low geothermal energy involves harnessing heat from shallow underground sources. This technology uses a heat pump connected to a vertical ground heat exchanger. This study analyzes the performance of geothermal heat pump (GSHP) systems with U-shaped vertical borehole heat exchangers. A new mathematical model that considers thermo-hydro-vapor phase change coupling has been developed. This model accurately simulates the complex interactions between heat and water transfer and phase change processes in unsaturated, stratified soil under various climatic and geological conditions in the studied region. Finally, this study evaluates the effect of the distance between the two arms of the heat exchanger, the distance between two piles, and the number of piles on the performance of the GSHP system. The findings indicate that soil surface temperature affects water vapor concentration, affecting evaporation. Cooling in winter changes the vapor pressure, forming a condensation zone. The coefficient of performance (COP) increases with the spacing between the arms of the U-shaped exchanger. At a spacing of two meters, the COP reaches 4 and 6.01 in heating and cooling mode. Furthermore, the results indicate that the energy efficiency of the system under investigation is optimized when the spacing between two heat exchangers is set at 2.5 meters. The final results demonstrate that there is an optimal threshold of four piles, at which point the total energy extracted is 47.15% higher than with a single pile. Beyond this value, a decline in productivity is observed.
- 11 September 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (19) , 14835-14847
Thermomechanical performance of new bio-based insulation material produced using fatty acids and date palm fibers
- 11 September 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (19) , 14835-14847
Thermomechanical performance of new bio-based insulation material produced using fatty acids and date palm fibers
- 14 July 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (16) , 12415-12426
Effect analysis of seasonal hydrothermal fluctuations on thermal performance of horizontal air–ground heat exchanger
- 14 July 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (16) , 12415-12426
Effect analysis of seasonal hydrothermal fluctuations on thermal performance of horizontal air–ground heat exchanger
- Open Access
- 7 July 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 278
Thermal effectiveness of different types of shallow horizontal heat exchangers arranged in single loop, series or parallel configurations
- 7 July 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 278
Open AccessThermal effectiveness of different types of shallow horizontal heat exchangers arranged in single loop, series or parallel configurations
- 22 January 2025
- Published by Springer Nature in Arabian Journal of Geosciences
- Vol. 18 (2) , 1-11
Numerical investigation on energy efficiency of horizontal heat pump systems in buildings heating and cooling: case study of Mostaganem (Algeria)
- 22 January 2025
- Published by Springer Nature in Arabian Journal of Geosciences
- Vol. 18 (2) , 1-11
Numerical investigation on energy efficiency of horizontal heat pump systems in buildings heating and cooling: case study of Mostaganem (Algeria)
- Open Access
- 5 November 2024
- Published by "IMS" Vogosca in Science, Engineering and Technology
- Vol. 5 (1)
Thermo-Mechanical Assessment of Bio-based Insulating Material Using Phase Change Materials and Date Palm Fibers
To mitigate extreme temperature fluctuations in arid southern Algerian cities, developing an internal thermal environment that is either independent of or only marginally influenced by external conditions is a viable solution. In this study, we successfully created a eutectic mixture of animal and plant fatty acids, excluding petroleum sources, consisting of 70% myristic acid (MA) and 30% stearic acid (SA). This phase change material (PCM) was then impregnated into date palm fiber waste (DPF) using a vacuum technique. The melting points of both the eutectic mixture and the impregnated date palm fiber were measured at 35°C and 34.5°C, respectively. Clay bricks, which are widely used in Algerian construction, were prepared with 75% dune sand and 10% lime. Date palm fibers impregnated with PCM were added in varying proportions (0.5%, 1%, 1.5%, 2%) to test the mechanical and thermal properties of the bricks. The results showed an improvement in thermal insulation, with a reduction in thermal conductivity by 11% for bricks containing 2% impregnated palm fibers. The compressive strength of these bricks remained within acceptable limits, regardless of whether the PCM was in a solid or liquid state. Numerical simulations showed that adding MA-SA/DPF to clay bricks contributed to a 30% reduction in outward heat flow in winter and a 25% reduction in inward heat flow in summer. This, in turn, resulted in a corresponding decrease in energy consumption.
- 5 November 2024
- Published by "IMS" Vogosca in Science, Engineering and Technology
- Vol. 5 (1)
Open AccessThermo-Mechanical Assessment of Bio-based Insulating Material Using Phase Change Materials and Date Palm Fibers
To mitigate extreme temperature fluctuations in arid southern Algerian cities, developing an internal thermal environment that is either independent of or only marginally influenced by external conditions is a viable solution. In this study, we successfully created a eutectic mixture of animal and plant fatty acids, excluding petroleum sources, consisting of 70% myristic acid (MA) and 30% stearic acid (SA). This phase change material (PCM) was then impregnated into date palm fiber waste (DPF) using a vacuum technique. The melting points of both the eutectic mixture and the impregnated date palm fiber were measured at 35°C and 34.5°C, respectively. Clay bricks, which are widely used in Algerian construction, were prepared with 75% dune sand and 10% lime. Date palm fibers impregnated with PCM were added in varying proportions (0.5%, 1%, 1.5%, 2%) to test the mechanical and thermal properties of the bricks. The results showed an improvement in thermal insulation, with a reduction in thermal conductivity by 11% for bricks containing 2% impregnated palm fibers. The compressive strength of these bricks remained within acceptable limits, regardless of whether the PCM was in a solid or liquid state. Numerical simulations showed that adding MA-SA/DPF to clay bricks contributed to a 30% reduction in outward heat flow in winter and a 25% reduction in inward heat flow in summer. This, in turn, resulted in a corresponding decrease in energy consumption.
- Open Access
- 5 November 2024
- Published by "IMS" Vogosca in Science, Engineering and Technology
- Vol. 5 (1)
Effect of Soil Salinity on Thermal Behavior of Sandy Soils Under a Sahara Climate
Soil salinity represents a harmful environmental problem that occurs either naturally or as a consequence of ineffective management practices by humans, especially in arid regions. Assessing ground temperature profile represents an important indicator for evaluating the performance of geothermal systems, used in air conditioning of building. This paper proposes a conceptual and numerical model for predicting the hydrothermal behavior of unsaturated soils. The effect of soil salinity was investigated in this research. Two soil types (sandy and sandy loam) were studied under three salinity levels. Moreover, the arid meteorological conditions of Sahara Desert were considered in the developed model. According to the results, it appears that sandy soils exhibit optimal thermal behavior at a moderate salinity concentration of C = 0.1 M, with increased surface temperatures during warmer periods and better heat conservation in colder conditions. Conversely, sandy loam soils respond most effectively at a higher salinity concentration of C = 0.2 M, particularly excelling in heat retention during the summer months. These results emphasize the intricate interaction between soil composition and salinity in regulating temperature patterns, providing important knowledge for enhancing soil management practices that are customized to particular soil types and environmental factors, with potential implications for geothermal applications.
- 5 November 2024
- Published by "IMS" Vogosca in Science, Engineering and Technology
- Vol. 5 (1)
Open AccessEffect of Soil Salinity on Thermal Behavior of Sandy Soils Under a Sahara Climate
Soil salinity represents a harmful environmental problem that occurs either naturally or as a consequence of ineffective management practices by humans, especially in arid regions. Assessing ground temperature profile represents an important indicator for evaluating the performance of geothermal systems, used in air conditioning of building. This paper proposes a conceptual and numerical model for predicting the hydrothermal behavior of unsaturated soils. The effect of soil salinity was investigated in this research. Two soil types (sandy and sandy loam) were studied under three salinity levels. Moreover, the arid meteorological conditions of Sahara Desert were considered in the developed model. According to the results, it appears that sandy soils exhibit optimal thermal behavior at a moderate salinity concentration of C = 0.1 M, with increased surface temperatures during warmer periods and better heat conservation in colder conditions. Conversely, sandy loam soils respond most effectively at a higher salinity concentration of C = 0.2 M, particularly excelling in heat retention during the summer months. These results emphasize the intricate interaction between soil composition and salinity in regulating temperature patterns, providing important knowledge for enhancing soil management practices that are customized to particular soil types and environmental factors, with potential implications for geothermal applications.
- 1 August 2020
- Published by Elsevier in Chemosphere
- Vol. 253, 126688
Effect of processing time on removal of harmful emerging salt pollutants from saline-sodic soil during electrochemical remediation
- 1 August 2020
- Published by Elsevier in Chemosphere
- Vol. 253, 126688
Effect of processing time on removal of harmful emerging salt pollutants from saline-sodic soil during electrochemical remediation
- Open Access
- 14 December 2018
- Published by Universidad de Antioquia in Revista Facultad de Ingeniería Universidad de Antioquia
- No. 90,p. 101-112
Laboratory evaluation of soil geotechnical properties via electrical conductivity
In recent years, the use of electrical methods has been improved considerably in several areas such as environment, agronomy, geophysics and geotechnics. Electrical resistivity may be used as a parameter in soil characterization; it may have many advantages for the determination of geotechnical factors influencing the behavior of soil. In this research, laboratory tests were carried out on natural sodic soil from the region of Ain Nouissy (Mostaganem) to investigate the geotechnical and chemical behavior of a natural soil using electrical resistivity measurements under various conditions. This study aims therefore to identify relationships between electrical resistivity of the soil and some physical and chemical parameters such as water content, porosity, salt concentration and pH. Moreover, electrical resistivity has been measured with the addition of salts into the natural soil. The results show that electrical resistivity reduced drastically with the addition of salt. The obtained results will be used to evaluate properties needed for soil characterization, as well as to track soil behavior with respect to salt concentration for use in soil remediation.
- 14 December 2018
- Published by Universidad de Antioquia in Revista Facultad de Ingeniería Universidad de Antioquia
- No. 90,p. 101-112
Open AccessLaboratory evaluation of soil geotechnical properties via electrical conductivity
In recent years, the use of electrical methods has been improved considerably in several areas such as environment, agronomy, geophysics and geotechnics. Electrical resistivity may be used as a parameter in soil characterization; it may have many advantages for the determination of geotechnical factors influencing the behavior of soil. In this research, laboratory tests were carried out on natural sodic soil from the region of Ain Nouissy (Mostaganem) to investigate the geotechnical and chemical behavior of a natural soil using electrical resistivity measurements under various conditions. This study aims therefore to identify relationships between electrical resistivity of the soil and some physical and chemical parameters such as water content, porosity, salt concentration and pH. Moreover, electrical resistivity has been measured with the addition of salts into the natural soil. The results show that electrical resistivity reduced drastically with the addition of salt. The obtained results will be used to evaluate properties needed for soil characterization, as well as to track soil behavior with respect to salt concentration for use in soil remediation.
- Open Access
- 1 January 2011
- Published by MathDoc/Centre Mersenne in Comptes Rendus Mécanique
- Vol. 339 (1) , 63-66
Reply to the comment by M. Rahman on “Influence of inter-granular void ratio on monotonic and cyclic undrained shear response of sandy soils” by M. Belkhatir et al. [C. R. Mecanique 338 (2010) 290–303]
- 1 January 2011
- Published by MathDoc/Centre Mersenne in Comptes Rendus Mécanique
- Vol. 339 (1) , 63-66
Open AccessReply to the comment by M. Rahman on “Influence of inter-granular void ratio on monotonic and cyclic undrained shear response of sandy soils” by M. Belkhatir et al. [C. R. Mecanique 338 (2010) 290–303]