Electrode Placement Accuracy in Robot-Assisted Asleep Deep Brain Stimulation
- 22 February 2019
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 47 (5) , 1212-1222
Abstract
Deep brain stimulation (DBS) involves the implantation of electrodes into specific central brain structures for the treatment of Parkinson’s disease. Image guidance and robot-assisted techniques have been developed to assist in the accuracy of electrode placement. Traditional DBS is performed with the patient awake and utilizes microelectrode recording for feedback, which yields lengthy operating room times. Asleep DBS procedures use imaging techniques to verify electrode placement. The objective of this study is to demonstrate the validity of an asleep robot-assisted DBS procedure that utilizes intraoperative imaging techniques for precise electrode placement in a large, inclusive cohort. Preoperative magnetic resonance imaging (MRI) was used to plan the surgical procedure for the 128 patients that underwent asleep DBS. During the surgery, robot assistance was used during the implantation of the electrodes. To verify electrode placement, intraoperative CT scans were fused with the preoperative MRIs. The mean radial error of all final electrode placements is 0.85 ± 0.38 mm. MRI-CT fusion error is 0.64 ± 0.40 mm. The average operating room time for bilateral and unilateral implantations are 139.3 ± 34.7 and 115.4 ± 42.1 min, respectively. This study shows the validity of the presented asleep DBS procedure using robot assistance and intraoperative CT verification for accurate electrode placement with shorter operating room times.Keywords
This publication has 29 references indexed in Scilit:
- Clinical outcomes following awake and asleep deep brain stimulation for Parkinson diseaseJournal of Neurosurgery, 2018
- Registration Accuracy of CT/MRI Fusion for Localisation of Deep Brain Stimulation Electrode Position: An Imaging Study and Systematic ReviewStereotactic and Functional Neurosurgery, 2016
- Review of Robotic Technology for Stereotactic NeurosurgeryIEEE Reviews in Biomedical Engineering, 2015
- Surgical Site Infections after Deep Brain Stimulation Surgery: Frequency, Characteristics and Management in a 10-Year PeriodPLOS ONE, 2014
- Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recordingJournal of Neurosurgery, 2013
- An International Survey of Deep Brain Stimulation Procedural StepsStereotactic and Functional Neurosurgery, 2012
- MRI-guided STN DBS in Parkinson's disease without microelectrode recording: efficacy and safetyJournal of Neurology, Neurosurgery & Psychiatry, 2010
- Artifacts in CT: Recognition and AvoidanceRadioGraphics, 2004
- Safety and Risk of Microelectrode Recording in Surgery for Movement DisordersStereotactic and Functional Neurosurgery, 2002
- Impact of thalamic deep brain stimulation on disability and health-related quality of life in patients with essential tremorJournal of Neurology, Neurosurgery & Psychiatry, 2002