System Level Framework for Assessing the Accuracy of Neonatal EEG Acquisition
Authors:
- Mark O'SullivanMOMark O'Sullivan
- Emanuel PopoviciEPEmanuel Popovici
- Andrea BocchinoABAndrea Bocchino
- Conor O'MahonyCOConor O'Mahony
- Geraldine BoylanGBGeraldine Boylan
- Andriy TemkoATAndriy Temko
Preprint
Abstract
Significant research has been conducted in recent years to design low-cost alternatives to the current EEG monitoring systems used in healthcare facilities. Testing such systems on a vulnerable population such as newborns is complicated due to ethical and regulatory considerations that slow down the technical development. This paper presents and validates a method for quantifying the accuracy of neonatal EEG acquisition systems and electrode technologies via clinical data simulations that do not require neonatal participants. The proposed method uses an extensive neonatal EEG database to simulate analogue signals, which are subsequently passed through electrical models of the skin-electrode interface, which are developed using wet and dry EEG electrode designs. The signal losses in the system are quantified at each stage of the acquisition process for electrode and acquisition board losses. SNR, correlation and noise values were calculated. The results verify that low-cost EEG acquisition systems are capable of obtaining clinical grade EEG. Although dry electrodes result in a significant increase in the skin-electrode impedance, accurate EEG recordings are still achievable.Keywords
All Related Versions
This publication has 12 references indexed in Scilit:
- Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodesJournal of Micromechanics and Microengineering, 2016
- Validation of a wireless dry electrode system for electroencephalographyJournal of NeuroEngineering and Rehabilitation, 2015
- Overcoming the practical challenges of electroencephalography for very preterm infants in the neonatal intensive care unitActa Paediatrica, 2015
- Spatial patterning of the neonatal EEG suggests a need for a high number of electrodesNeuroImage, 2013
- Creation of a Human Head Phantom for Testing of Electroencephalography Equipment and TechniquesIEEE Transactions on Biomedical Engineering, 2012
- Comparison of Dry and Gel Based Electrodes for P300 Brain–Computer InterfacesFrontiers in Neuroscience, 2012
- Development of an embedded system and MATLAB-based GUI for online acquisition and analysis of ECG signalMeasurement, 2010
- A new EEG recording system for passive dry electrodesClinical Neurophysiology, 2010
- Defining the gap between electrographic seizure burden, clinical expression and staff recognition of neonatal seizuresArchives of Disease in Childhood - Fetal and Neonatal Edition, 2007
- Scalp electrode impedance, infection risk, and EEG data qualityClinical Neurophysiology, 2001