MOMark O'Sullivan

Mark O'Sullivan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mark O'Sullivan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis of a Low-Cost EEG Monitoring System and Dry Electrodes toward Clinical Use in the Neonatal ICU

    by Mark O’sullivan, Andriy Temko, Andrea Bocchino, Conor O’mahony, Geraldine Boylan, Emanuel Popovici

    Electroencephalography (EEG) is an important clinical tool for monitoring neurological health. However, the required equipment, expertise, and patient preparation inhibits its use outside of tertiary care. Non-experts struggle to obtain high-quality EEG due to its low amplitude and artefact susceptibility. Wet electrodes are currently used, which require abrasive/conductive gels to reduce skin-electrode impedance. Advances in dry electrodes, which do not require gels, have simplified this process. However, the assessment of dry electrodes on neonates is limited due to health and safety barriers. This study presents a simulation framework for assessing the quality of EEG systems using a neonatal EEG database, without the use of human participants. The framework is used to evaluate a low-cost EEG acquisition system and compare performance of wet and dry (Micro Transdermal Interface Platforms (MicroTIPs), g.tec-g.SAHARA) electrodes using accurately acquired impedance models. A separate experiment assessing the electrodes on adult participants was conducted to verify the simulation framework’s efficacy. Dry electrodes have higher impedance than wet electrodes, causing a reduction in signal quality. However, MicroTIPs perform comparably to wet electrodes at the frontal region and g.tec-g.SAHARA performs well at the occipital region. Using the simulation framework, a 25dB signal-to-noise ratio (SNR) was obtained for the low-cost EEG system. The tests on adults closely matched the simulated results.


  • Open Access

    System Level Framework for Assessing the Accuracy of Neonatal EEG Acquisition

    by Mark O'Sullivan, Emanuel Popovici, Andrea Bocchino, Conor O'Mahony, Geraldine Boylan, Andriy Temko

    Significant research has been conducted in recent years to design low-cost alternatives to the current EEG monitoring systems used in healthcare facilities. Testing such systems on a vulnerable population such as newborns is complicated due to ethical and regulatory considerations that slow down the technical development. This paper presents and validates a method for quantifying the accuracy of neonatal EEG acquisition systems and electrode technologies via clinical data simulations that do not require neonatal participants. The proposed method uses an extensive neonatal EEG database to simulate analogue signals, which are subsequently passed through electrical models of the skin-electrode interface, which are developed using wet and dry EEG electrode designs. The signal losses in the system are quantified at each stage of the acquisition process for electrode and acquisition board losses. SNR, correlation and noise values were calculated. The results verify that low-cost EEG acquisition systems are capable of obtaining clinical grade EEG. Although dry electrodes result in a significant increase in the skin-electrode impedance, accurate EEG recordings are still achievable.

  • V2Hz: Music composition from wind turbine energy using a finite-state machine

    by Mark O'Sullivan, Bruno Srbinovski, Andriy Temko, Emanuel Popovici, Hugh McCarthy

    The study presents a multi-disciplinary application of the Internet of Things (IoT) benefiting both the engineering and music community. A music composition algorithm based on a finite-state machine was designed to receive and manipulate wind turbine voltage output data into a musically aesthetic composition. The algorithm adapts common western music theory and imposes these limitations on the wind turbine output voltage stream. The front-end of the system employs various transmission protocols. The data is streamed to a server on-site at the wind farm using transmission control protocol, and then received offsite via TCP/IP. The back-end of the system processes the digital signals, and finally constructs Musical Instrument Digital Interface messages, which can be routed to a host of various music synthesis software programs. The voltage output values of each wind turbine are directly represented in both the amplitude and frequency characteristics of the audio. Thus, the audio serves as an accurate real-time monitoring and maintenance tool for the wind farm data from an offsite location.