Microneedle-Array-Electrode-Based ECG with PPG Sensor for Cuffless Blood Pressure Estimation
Open Access
- 19 December 2025
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 35
Abstract
Continuous blood pressure (BP) measurement is essential for real-time hypertension management and the prevention of related complications. To address this need, a cuffless BP estimation technique utilizing biosignals from wearable devices has gained significant attention. This study proposes a feasibility approach that integrates microneedle array electrodes (MNE) for ECG acquisition with photoplethysmogram (PPG) sensors for cuffless BP estimation. The algorithm employed is a baseline multivariate regression model using PTT and RR intervals, while the novelty lies in the hardware design aimed at improving signal quality and long-term wearability. The algorithm’s performance was validated using the Medical Information Mart for Intensive Care (MIMIC) database, achieving a mean error range of ±5.28 mmHg for the SBP and ±2.81 mmHg for the DBP. Additionally, the comparison with 253 measurements from three volunteers against an automated sphygmomanometer indicated an accuracy within ±25%. Therefore, these findings demonstrate the feasibility of an MNE-based ECG with PPG for BP integration for cuffless monitoring of SBP and DBP in daily life. The MIMIC-based evaluation was performed to verify the feasibility of the regression model under ideal public-database conditions. The volunteer experiment, performed with the developed MNE-ECG hardware, served as a separate preliminary feasibility test to observe hardware behavior in real-world measurements.Keywords
Funding Information
- National Research Foundation of Korea (NRF-2023R1A2C1003669)
This publication has 33 references indexed in Scilit:
- MIMIC-BP: A curated dataset for blood pressure estimationScientific Data, 2024
- A review of machine learning methods for non-invasive blood pressure estimationJournal of Clinical Monitoring and Computing, 2024
- A review: Blood pressure monitoring based on PPG and circadian rhythmAPL Bioengineering, 2024
- PPG-based blood pressure estimation can benefit from scalable multi-scale fusion neural networks and multi-task learningBiomedical Signal Processing and Control, 2022
- Blood pressure increase during hospitalization for COVID-19European Journal of Internal Medicine, 2022
- Home Blood Pressure and Telemedicine: A Modern Approach for Managing Hypertension During and After COVID-19 PandemicHigh Blood Pressure & Cardiovascular Prevention, 2021
- Simplified blood pressure measurement approaches and implications for hypertension screening: the Atherosclerosis Risk in Communities studyJournal Of Hypertension, 2020
- Cuffless blood pressure estimation from electrocardiogram and photoplethysmogram using waveform based ANN-LSTM networkBiomedical Signal Processing and Control, 2019
- The MIMIC Code Repository: enabling reproducibility in critical care researchJournal of the American Medical Informatics Association, 2017
- Microneedle-based electrodes with integrated through-silicon via for biopotential recordingSensors and Actuators A: Physical, 2012