Sungmin Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sungmin Lee has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Daesoo Kim
Department of Electronics Engineering, Gachon University, Seongnam 13210, Republic of Korea
1 shared publication - Hyun-Moon Park
Energy Mining, Co., Ltd., Daehak 4-ro, Yeongtong-gu, Suwon 16226, Republic of Korea
1 shared publication - Soyoung Yang
Department of Electronics Engineering, Gachon University, Seongnam 13210, Republic of Korea
1 shared publication - Sungbo Cho
Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, Korea
1 shared publication - Zeeshan Haider
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 19 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 35
Microneedle-Array-Electrode-Based ECG with PPG Sensor for Cuffless Blood Pressure Estimation
Continuous blood pressure (BP) measurement is essential for real-time hypertension management and the prevention of related complications. To address this need, a cuffless BP estimation technique utilizing biosignals from wearable devices has gained significant attention. This study proposes a feasibility approach that integrates microneedle array electrodes (MNE) for ECG acquisition with photoplethysmogram (PPG) sensors for cuffless BP estimation. The algorithm employed is a baseline multivariate regression model using PTT and RR intervals, while the novelty lies in the hardware design aimed at improving signal quality and long-term wearability. The algorithm’s performance was validated using the Medical Information Mart for Intensive Care (MIMIC) database, achieving a mean error range of ±5.28 mmHg for the SBP and ±2.81 mmHg for the DBP. Additionally, the comparison with 253 measurements from three volunteers against an automated sphygmomanometer indicated an accuracy within ±25%. Therefore, these findings demonstrate the feasibility of an MNE-based ECG with PPG for BP integration for cuffless monitoring of SBP and DBP in daily life. The MIMIC-based evaluation was performed to verify the feasibility of the regression model under ideal public-database conditions. The volunteer experiment, performed with the developed MNE-ECG hardware, served as a separate preliminary feasibility test to observe hardware behavior in real-world measurements.
- 19 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 35
Open AccessMicroneedle-Array-Electrode-Based ECG with PPG Sensor for Cuffless Blood Pressure Estimation
Continuous blood pressure (BP) measurement is essential for real-time hypertension management and the prevention of related complications. To address this need, a cuffless BP estimation technique utilizing biosignals from wearable devices has gained significant attention. This study proposes a feasibility approach that integrates microneedle array electrodes (MNE) for ECG acquisition with photoplethysmogram (PPG) sensors for cuffless BP estimation. The algorithm employed is a baseline multivariate regression model using PTT and RR intervals, while the novelty lies in the hardware design aimed at improving signal quality and long-term wearability. The algorithm’s performance was validated using the Medical Information Mart for Intensive Care (MIMIC) database, achieving a mean error range of ±5.28 mmHg for the SBP and ±2.81 mmHg for the DBP. Additionally, the comparison with 253 measurements from three volunteers against an automated sphygmomanometer indicated an accuracy within ±25%. Therefore, these findings demonstrate the feasibility of an MNE-based ECG with PPG for BP integration for cuffless monitoring of SBP and DBP in daily life. The MIMIC-based evaluation was performed to verify the feasibility of the regression model under ideal public-database conditions. The volunteer experiment, performed with the developed MNE-ECG hardware, served as a separate preliminary feasibility test to observe hardware behavior in real-world measurements.