Abstract
Quantum fluctuations in the intensity of an optical probe is noise which limits measurement precision in absorption spectroscopy. Increased probe power can offer greater precision; however, this strategy is often constrained by sample saturation. Here, we analyze measurement precision for a generalized absorption model in which we account for saturation and explore its effect on both classical and quantum probe performance. We present a classical probe-sample optimization strategy to maximize precision and find that optimal probe powers always fall within the saturation regime. We apply our optimization strategy to two examples, high-precision Doppler broadened thermometry and an absorption spectroscopy measurement of chlorophyll a. We derive a limit on the maximum precision gained from using a nonclassical probe and find a strategy capable of saturating this bound. We evaluate amplitude-squeezed light as a viable experimental probe state and find it capable of providing precision that reaches to within >85% of the ultimate quantum limit with currently available technology.
Funding Information
  • Engineering and Physical Sciences Research Council (EP/LO15730/1, EP/M024385/1, EP/R024170/1, EP/R513179/1, EP/T00097X/1)
  • Horizon 2020 (892242)
  • Leverhulme Trust (ECF-2018-276)

This publication has 61 references indexed in Scilit: