Jake Biele
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jake Biele has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan C. F. Matthews
Quantum Engineering Technology Labs, H. H. Wills Physics Laboratory and Department of Electrical & Electronic Engineering, University of Bristol, Bristol BS8 1FD, United Kingdom
2 shared publications - Joshua W. Silverstone
Quantum Engineering Technology Labs, H. H. Wills Physics Laboratory and Department of Electrical and Electronic Engineering, University of Bristol, BS8 1FD, UK
2 shared publications - Euan J. Allen
Quantum Engineering Technology Labs, H. H. Wills Physics Laboratory and Department of Electrical & Electronic Engineering, University of Bristol, Bristol BS8 1FD, United Kingdom
1 shared publication - Joel F. Tasker
Quantum Engineering Technology Labs, H. H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL, UK
1 shared publication Sabine Wollmann
Quantum Engineering Technology Labs, H. H. Wills Physics Laboratory and Department of Electrical & Electronic Engineering, University of Bristol, Bristol BS8 1FD, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 22 February 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (5) , 7716-7724
Shot-noise limited homodyne detection for MHz quantum light characterisation in the 2 µm band
Characterising quantum states of light in the 2 µm band requires high-performance shot-noise limited detectors. Here, we present the characterisation of a homodyne detector that we use to observe vacuum shot-noise via homodyne measurement with a 2.07 µm pulsed mode-locked laser. The device is designed primarily for pulsed illumination. It has a 3-dB bandwidth of 13.2 MHz, total conversion efficiency of 57% at 2.07 µm, and a common-mode rejection ratio of 48 dB at 39.5 MHz. The detector begins to saturate at 1.8 mW with 9 dB of shot-noise clearance at 5 MHz. This demonstration enables the characterisation of megahertz-quantum optical behaviour in the 2 µm band and provides a guide of how to design a 2 µm homodyne detector for quantum applications.
- 22 February 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (5) , 7716-7724
Open AccessShot-noise limited homodyne detection for MHz quantum light characterisation in the 2 µm band
Characterising quantum states of light in the 2 µm band requires high-performance shot-noise limited detectors. Here, we present the characterisation of a homodyne detector that we use to observe vacuum shot-noise via homodyne measurement with a 2.07 µm pulsed mode-locked laser. The device is designed primarily for pulsed illumination. It has a 3-dB bandwidth of 13.2 MHz, total conversion efficiency of 57% at 2.07 µm, and a common-mode rejection ratio of 48 dB at 39.5 MHz. The detector begins to saturate at 1.8 mW with 9 dB of shot-noise clearance at 5 MHz. This demonstration enables the characterisation of megahertz-quantum optical behaviour in the 2 µm band and provides a guide of how to design a 2 µm homodyne detector for quantum applications.
- 22 November 2021
- Published by American Physical Society (APS) in Physical Review A
- Vol. 104 (5) , 053717
Maximizing precision in saturation-limited absorption measurements
Quantum fluctuations in the intensity of an optical probe is noise which limits measurement precision in absorption spectroscopy. Increased probe power can offer greater precision; however, this strategy is often constrained by sample saturation. Here, we analyze measurement precision for a generalized absorption model in which we account for saturation and explore its effect on both classical and quantum probe performance. We present a classical probe-sample optimization strategy to maximize precision and find that optimal probe powers always fall within the saturation regime. We apply our optimization strategy to two examples, high-precision Doppler broadened thermometry and an absorption spectroscopy measurement of chlorophyll a. We derive a limit on the maximum precision gained from using a nonclassical probe and find a strategy capable of saturating this bound. We evaluate amplitude-squeezed light as a viable experimental probe state and find it capable of providing precision that reaches to within of the ultimate quantum limit with currently available technology.- 22 November 2021
- Published by American Physical Society (APS) in Physical Review A
- Vol. 104 (5) , 053717
Maximizing precision in saturation-limited absorption measurements
Quantum fluctuations in the intensity of an optical probe is noise which limits measurement precision in absorption spectroscopy. Increased probe power can offer greater precision; however, this strategy is often constrained by sample saturation. Here, we analyze measurement precision for a generalized absorption model in which we account for saturation and explore its effect on both classical and quantum probe performance. We present a classical probe-sample optimization strategy to maximize precision and find that optimal probe powers always fall within the saturation regime. We apply our optimization strategy to two examples, high-precision Doppler broadened thermometry and an absorption spectroscopy measurement of chlorophyll a. We derive a limit on the maximum precision gained from using a nonclassical probe and find a strategy capable of saturating this bound. We evaluate amplitude-squeezed light as a viable experimental probe state and find it capable of providing precision that reaches to within of the ultimate quantum limit with currently available technology.