A small angle of shunting and detectable shunting inlet may predict successful exclusive transvenous closure of patent ductus arteriosus with a 3-year follow-up
Authors:
Open Access
- 11 November 2026
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 13, 1977237
Abstract
Background: The transvenous V-method simplifies transcatheter patent ductus arteriosus (PDA) closure compared with the arteriovenous (AV) method and retrograde transarterial coil occlusion, with fewer complications, but it carries variable failure rates. This study aimed to identify preoperative transthoracic echocardiography (TTE) predictors for V-method failure and establish a practical model to optimize procedural strategies. Methods: A total of 403 consecutive patients undergoing transcatheter PDA closure in Fujian Medical University Union Hospital between October 2014 and July 2019 were retrospectively enrolled and randomly split to training ( n = 282) and internal validation ( n = 121) cohorts at a 7:3 ratio. LASSO regression was performed to screen independent predictors. Model performance was validated via ROC, calibration and decision curve analysis. All patients received standardized 3-year postoperative follow-up. Results: Overall, 323 patients completed V-method closure, and 80 converted to the AV-method. The median age was 7 years (6 months-73 years) and an average PDA size of 4.43 mm (1.0mm–14.5 mm). Large shunt angle (defined as shunt beam–PDA inlet plane angle; A larger angle may indicate more perpendicular insertion to the pulmonary artery wall) and undetectable PDA shunting inlet on preoperative TTE were independent predictors of V-method failure. The dual-index model achieved excellent predictive performance with AUCs of 0.933 (training) and 0.910 (validation), along with favorable calibration and clinical net benefit. The optimal cut-off value for the model was defined as an undetectable PDA shunting inlet or a shunt angle > 81.61°, with a sensitivity of 89.5% and a specificity of 96.4%. At 3-year follow-up, no signal of excess harm was detected in either group. Conclusion: A small angle of shunting and detectable shunting inlet by echocardiography may predict successful exclusive transvenous PDA closure. The 3-year follow-up suggested the safety and efficacy of the exclusive transvenous access.Keywords
This publication has 16 references indexed in Scilit:
- Transcatheter Intervention for Congenital Defects Involving the Great VesselsJACC, 2021
- 2020 ESC Guidelines for the management of adult congenital heart diseaseEuropean Heart Journal, 2020
- Transcatheter closure through single venous approach for young children with patent ductus arteriosusMedicine, 2018
- Transthoracic Echocardiography as an Alternative Major Guidance to Angiography During Transcatheter Closure of Patent Ductus Arteriosus: Technical Feasibility and Clinical RelevancePediatric Cardiology, 2014
- Transcatheter Closure of Persistent Ductus Arteriosus in AdultsJournal of Interventional Cardiology, 2012
- Indications for Cardiac Catheterization and Intervention in Pediatric Cardiac DiseaseCirculation, 2011
- ESC Guidelines for the management of grown-up congenital heart disease (new version 2010): The Task Force on the Management of Grown-up Congenital Heart Disease of the European Society of Cardiology (ESC)European Heart Journal, 2010
- Transcatheter closure of the arterial duct without arterial accessCardiology in the Young, 2009
- Comprehensive assessment of patent ductus arteriosus by echocardiography before transcatheter closureJournal of the American Society of Echocardiography, 2002
- Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusionThe American Journal of Cardiology, 1989