Early Detection of Local Tumor Progression after Irreversible Electroporation (IRE) of Hepatocellular Carcinoma Using Gd-EOB-DTPA-Based MR Imaging at 3T
Open Access
Abstract
This single-center retrospective study was conducted to improve the early detection of local tumor progression (LTP) after irreversible electroporation (IRE) of a hepatocellular carcinoma (HCC) using gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-based 3T MR imaging and to identify helpful signal characteristics by comparing 23 patients with and 60 patients without LTP. To identify the differences in the sensitivity of MRI sequences, the specificity, positive prediction value, negative prediction value (NPV) and diagnostic odds ratio were calculated. A chi-squared test, two-tailed student’s t-test and binary logistic regression model were used to detect distinct patient characteristics and variables for the prediction of LTP. LTP was mostly detected in the peripheral ablation zone (82.6%) within the first six months (87.0%). The central LTP ablation area presented more hypointensities in T1 p.v. (sensitivity: 95.0%; NPV: 90.0%) and in T1 d.p. (sensitivity: 100.0%; NPV: 100.0) while its peripheral part showed more hyperintensities in T2 BLADE (sensitivity: 95.5%; NPV: 80.0%) and in diffusion sequences (sensitivity: 90.0%). Liver cirrhosis seems to be an unfavorable prognosticator for LTP (p = 0.039). In conclusion, LTP mostly occurs in the peripheral ablation zone within six months after IRE. Despite often exhibiting atypical Gd-EOB-DTPA MR signal characteristics, T2 BLADE and diffusion sequences were helpful for their detection in the peripheral zone while T1 p.v. and T1 d.p. had the highest sensitivity in the central zone.Keywords
This publication has 36 references indexed in Scilit:
- Irreversible Electroporation Ablation (IRE) of Unresectable Soft Tissue Tumors: Learning Curve Evaluation in the First 150 Patients TreatedPLOS ONE, 2013
- Irreversible Electroporation for Unresectable Hepatocellular Carcinoma: Initial Experience and Review of Safety and OutcomesTechnology in Cancer Research & Treatment, 2013
- Irreversible Electroporation in Porcine LiverInvestigative Radiology, 2012
- Safety and early efficacy of irreversible electroporation for hepatic tumors in proximity to vital structuresJournal of Surgical Oncology, 2012
- Ablation of Perivascular Hepatic Malignant Tumors with Irreversible ElectroporationJournal of the American College of Surgeons, 2012
- Acute Portal Venous Injury After Microwave Ablation in an In Vivo Porcine Model: A Rare Possible ComplicationJournal of Vascular and Interventional Radiology, 2011
- Investigation of the Safety of Irreversible Electroporation in HumansJournal of Vascular and Interventional Radiology, 2011
- Management of Hepatocellular Carcinoma: An Update ΔσHepatology, 2011
- Quality Improvement Guidelines for Radiofrequency Ablation of Liver TumoursCardioVascular and Interventional Radiology, 2009
- Tumor Ablation with Radio-frequency EnergyRadiology, 2000