Lukas Philipp Beyer

Lukas Philipp Beyer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lukas Philipp Beyer has a total of 171 co-authors. Here are the top co-authors by number of shared publications:

  • Christian Stroszczynski

    Department of Radiology, University Hospital Regensburg , Regensburg , Germany

    24 shared publications
  • C. Stroszczynski

    Department of Radiology, University Hospital Regensburg, Regensburg, Germany

    20 shared publications
  • Philipp Wiggermann

    Department of Radiology, Hospital Braunschweig , Braunschweig , Germany

    18 shared publications
  • P. Wiggermann

    Department of Radiology and Nuclear Medicine, Hospital Braunschweig, Braunschweig, Germany

    17 shared publications
  • E.M. Jung

    Institute of Radiology, University Hospital Regensburg, Regensburg, Germany

    9 shared publications
  • B. Pregler

    Department of Radiology, University Medical Center Regensburg, Germany

    8 shared publications

Latest Publications

  • Open Access

    Similar complication rates for irreversible electroporation and thermal ablation in patients with hepatocellular tumors

    by Niklas Verloh, Isabel Jensch, Lukas Lürken, Michael Haimerl, Marco Dollinger, Philipp Renner, Philipp Wiggermann, Jens Martin Werner, Florian Zeman, Christian Stroszczynski, et al.

    Sciendo provides publishing services and solutions to academic and professional organizations and individual authors. We publish journals, books, conference proceedings and a variety of other publications.

  • Open Access

    Stereotactic Microwave Ablation of Hepatocellular Carcinoma: The Impact of Tumor Size and Minimal Ablative Margin on Therapeutic Success

    by Antonia-Maria Pausch, Tamam Ghali, Tobias Wertheimer, Florian Zeman, Karolina Mueller, Michael Christian Doppler, Ingo Einspieler, Lukas Philipp Beyer, Stephan Schleder, Christian Stroszczynski, et al.

    Background: Microwave ablation (MWA) has gained relevance in the treatment of hepatic malignancies and especially in hepatocellular carcinoma (HCC), and it is an important alternative to surgery. The purpose of the study was to evaluate whether the minimal ablative margin (MAM) or the initial tumor size has a greater effect on the success of stereotactic MWA of HCC regarding the time to local tumor progression (LTP) and overall survival (OS). Methods: 88 patients, who received stereotactic MWA of 127 tumor lesions with a curative intention were included in this single-center, retrospective study. The MAM was evaluated in a side-by-side comparison of pre- and post-ablative, contrast-enhanced slice imaging. A Cox proportional hazard model with a frailty term was computed to assess the influence of the MAM and the maximum tumor diameter on the time to LTP and the OS. Results: The maximum tumor diameter was identified as a significant positive predictor for LTP (hazard ratio 1.04, 95% CI 1.00–1.08, p = 0.03), but it was not a significant positive predictor for the OS (p = 0.20). The MAM did not have a significant influence on LTP-free survival (p = 0.23) and OS (p = 0.67). Conclusion: For the successful stereotactic MWA of HCC, the MAM and maximum tumor diameter might not have an influence on the OS, but the maximum tumor diameter seems to be an independent predictor of the time to LTP.


  • Open Access

    Assessment of Rib Fracture in Acute Trauma Using Automatic Rib Segmentation and a Curved, Unfolded View of the Ribs: Is There a Saving of Time?

    by Benedikt Pregler, Lukas Philipp Beyer, Natascha Platz Batista da Silva, Sebastian Steer, Florian Zeman, Daniel Popp, Christian Stroszczynski, René Müller-Wille

    Introduction: The fast and accurate diagnosis of rib fractures in polytrauma patients is important to reduce the mortality rate and relieve long-term pain and complications. Aim: To evaluate the diagnostic accuracy and potential time savings using automatic rib segmentation and a curved, unfolded view for the detection of rib fractures in trauma patients. Methods: The multidetector computed tomography raw data of 101 consecutive polytrauma patients (72 men; mean age 45 years, age range 17 to 84 years) admitted to a university hospital were retrospectively post-processed to generate a curved, unfolded view of the rib cage. No manual corrections were performed. Patients with reconstruction errors and movement artifacts were excluded from further analysis. All fractures were identified and classified by the study coordinator using the original data set. Two readers (reader 1 and reader 2) evaluated the original axial sections and the unfolded view, separately. The fracture locations, fracture type, and reading times were recorded. Sensitivity and specificity were calculated on a per-rib basis using a ratio estimator. Cohen’s Kappa was calculated as an index of inter-rater agreement. Results: 26 of 101 patients (25.7%) were excluded from further analysis owing to breathing artifacts (6.9%) or incorrect centerline computation in the unfolded view (18.8%). In total, 107 (5.9%) of 1800 ribs were fractured in 25 (33%) of 75 patients. The unfolded view had a sensitivity/specificity of 81%/100% (reader 1) and 71%/100% (reader 2) compared to 94%/100% (reader 1; p = 0.002/p = 0.754) and 63%/99% (reader 2; p < 0.001/p = 0.002). The sensitivity (reader 1; reader 2) was poor for buckled fractures (31%; 38%), moderate for undislocated fractures (78%; 62%), and good for dislocated fractures (94%; 90%). The assessment of the unfolded view was performed significantly faster than that of the original layers (19.5 ± 9.4 s vs. 68.6 ± 32.4 s by reader 1 (p < 0.001); 24.1 ± 9.5 s vs. 40.2 ± 12.7 s by reader 2 (p < 0.001)). Both readers demonstrated a very high interobserver agreement for the unfolded view (κ = 0.839) but only a moderate agreement for the original view (κ = 0.529). Conclusion: Apart from a relatively high number of incorrect centerline reconstructions, the unfolded view of the rib cage allows a faster diagnosis of dislocated rib fractures.


  • Open Access

    Detection of Incomplete Irreversible Electroporation (IRE) and Microwave Ablation (MWA) of Hepatocellular Carcinoma (HCC) Using Iodine Quantification in Dual Energy Computed Tomography (DECT)

    by Wolf Bäumler, Lukas Philipp Beyer, Lukas Lürken, Philipp Wiggermann, Christian Stroszczynski, Marco Dollinger, Andreas Schicho

    Early detection of local tumor progression (LTP) after irreversible electroporation (IRE) and microwave ablation (MWA) of hepatocellular carcinoma (HCC) remains challenging. The goal of this study was to identify cases with insufficient ablation and prevent HCC recurrencies by measuring iodine uptake using dual-energy computed tomography (DECT). In 54 HCC-patients, the volumetric iodine concentration (VIC) of the central and peripheral ablation area was evaluated by DECT within 24 h after IRE or MWA. Follow-up was performed with CT and/or MRI at 6 weeks, 3, 6, 9, and 12 months, respectively. In both groups, LTP was solely detected in the peripheral area (IRE: n = 4; MWA: n = 4) and LTP patients showed significantly higher VIC values in the peripheral zone than patients without LTP (IRE: * p = 0.0005; MWA: * p = 0.000). In IRE-LTP patients, no significant difference between the VIC values of non-ablated liver tissue and the peripheral zone was detected (p = 0.155). The peripheral zones of IRE patients without LTP (* p = 0.000) and MWA patients, irrespective of the presence of LTP (LTP: * p = 0.005; without LTP: * p = 0.000), showed significantly lower VIC values than non-ablated liver parenchyma. Higher BCLC tumor stages were indicative for LTP (* p = 0.008). The study suggests that elevated iodine uptake in the peripheral ablation zone could help identify LTP after IRE and MWA of HCC.


  • Open Access

    Early Detection of Local Tumor Progression after Irreversible Electroporation (IRE) of Hepatocellular Carcinoma Using Gd-EOB-DTPA-Based MR Imaging at 3T

    by Wolf Bäumler, Philipp Wiggermann, Lukas Lürken, Marco Dollinger, Christian Stroszczynski, Lukas P. Beyer, Andreas Schicho

    This single-center retrospective study was conducted to improve the early detection of local tumor progression (LTP) after irreversible electroporation (IRE) of a hepatocellular carcinoma (HCC) using gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-based 3T MR imaging and to identify helpful signal characteristics by comparing 23 patients with and 60 patients without LTP. To identify the differences in the sensitivity of MRI sequences, the specificity, positive prediction value, negative prediction value (NPV) and diagnostic odds ratio were calculated. A chi-squared test, two-tailed student’s t-test and binary logistic regression model were used to detect distinct patient characteristics and variables for the prediction of LTP. LTP was mostly detected in the peripheral ablation zone (82.6%) within the first six months (87.0%). The central LTP ablation area presented more hypointensities in T1 p.v. (sensitivity: 95.0%; NPV: 90.0%) and in T1 d.p. (sensitivity: 100.0%; NPV: 100.0) while its peripheral part showed more hyperintensities in T2 BLADE (sensitivity: 95.5%; NPV: 80.0%) and in diffusion sequences (sensitivity: 90.0%). Liver cirrhosis seems to be an unfavorable prognosticator for LTP (p = 0.039). In conclusion, LTP mostly occurs in the peripheral ablation zone within six months after IRE. Despite often exhibiting atypical Gd-EOB-DTPA MR signal characteristics, T2 BLADE and diffusion sequences were helpful for their detection in the peripheral zone while T1 p.v. and T1 d.p. had the highest sensitivity in the central zone.


  • Open Access

    Evaluation of Alterations to Bile Ducts and Laboratory Values During the First 3 Months After Irreversible Electroporation of Malignant Hepatic Tumors

    by Wolf Bäumler, Mareike Sebald, Ingo Einspieler, Andreas Schicho, Jan Schaible, Philipp Wiggermann, Marco Dollinger, Christian Stroszczynski, Lukas Philipp Beyer

    Purpose: To assess the incidence and evolution of biliary alterations adjacent to the ablation area in patients with hepatic malignancies during the first 3 months after percutaneous irreversible electroporation (IRE) and to investigate associated changes in laboratory values. Material and Methods: Bile ducts located within a ≤ 1.0 cm radius of the ablation zone were analyzed in 45 patients by preinterventional and postinterventional MRI (1– 3 days, 6 weeks, and 3 months after IRE). Moreover, levels of alkaline phosphatase (AP) and serum bilirubin (SB) were examined for evidence of bile duct injury. Biliary alterations and the presence of postinterventional-elevated laboratory levels were correlated with features of the lesions, patients, ablation procedures, and laboratory values. Results: A total of 80 bile ducts were located within a 1.0 cm radius of the ablation zone: 59 were encased, 16 were abutting and 5 were located within a radius of 0.1– 1.0 cm of the ablation area. In total, 38 biliary injuries (narrowing, n=22; dilatation, n=14; biloma, n=2) were detected, 3 cases of narrowing occurred for the first time 6 weeks and 3 months after IRE, 21 alterations (dilatation: n=9; narrowing; n=10; biloma: n=2) had resolved during the first 6 weeks, 1 alteration (dilatation: n=1) had resolved by the last follow-up control. Three months after IRE, 19 patients showed elevated levels of AP, whereas SB levels were increased in 10 cases. No significant association between biliary alterations or postinterventional-elevated laboratory values and the investigated characteristics of lesions, patients, ablation procedures or laboratory values could be proven. Conclusion: Different alterations of bile ducts adjacent to an IRE ablation zone are common, of which dilatation and especially narrowing commonly represent a long-term complication after IRE. Moreover, a definite correlation between the frequently observed prolonged post-ablative elevation of AP- and SB-levels and the postinterventional biliary alterations could not be proven.


  • Open Access

    Full-Core Biopsy Systems Take Larger Liver Tissue Samples with Lower Fragmentation Rates Than Conventional Side-Notch Systems: A Randomized Trial

    by Jan Schaible, Kirsten Utpatel, Niklas Verloh, Ingo Einspieler, Benedikt Pregler, Florian Zeman, Philipp Wiggermann, Andreas G Schreyer, Christian Stroszczynski, Lukas P Beyer

    Background: The aim of this study was to compare the histopathological quality and physical features of the specimen of a full-core end-cut biopsy system with that of the standard side-notch system for liver biopsies. Methods: A full-core end-cut 16G biopsy device and a standard side-notch 16G needle were used to take biopsies of unclear liver lesions. Patients were randomized in two groups of 16 patients each. The primary endpoint of this prospective study was the core length measured using a dedicated microscope imaging software. Secondary endpoints were the quality of the specimen rated by an independent pathologist unaware of the device (scale from 1 to 5; with 1 as best and 5 as worst), the core diameter (determined by the microscopic imaging software) and presence of fragmentation (evaluated by the pathologist). Results: For the full-core (FC) and side-notch (SN) groups, the mean core length was similar with 13,599 μm and 11,570 μm (p=0.131), respectively. The quality of the specimen was significantly better in the FC-group with an average rating of 1.68 vs 2.50 (p=0.009). The fragmentation rate in the FC-group was statistically significantly lower at 2/27 (7%) than in the SN-group at 13/33 (39%) (p=0.021). The diameter in the FC-group was 1042 μm vs 930 μm in SN-group (p=0.018).


  • Ablation of Hepatocellular Carcinoma

    by Lukas Beyer, Lukas Luerken

  • Open Access

    Incidence and evolution of venous thrombosis during the first 3 months after irreversible electroporation of malignant hepatic tumours

    by W. Bäumler, M. Sebald, I. Einspieler, P. Wiggermann, A. Schicho, J. Schaible, L. Lürken, M. Dollinger, C. Stroszczynski, L. P. Beyer

    The incidence and evolution of venous thrombosis adjacent to the ablation zone after percutaneous irreversible electroporation (IRE) were evaluated to identify potential risk factors in patients with hepatic malignancies. 205 venous structures (in 87 patients) within a ≤1.0 cm radius of the ablation zone were assessed after IRE of 112 hepatic lesions (74 primary, 38 secondary hepatic malignancies) by pre-interventional and post-interventional (1–3 days, 6 weeks and 3 months after IRE) contrast-enhanced magnetic resonance imaging. The relationships between venous thrombosis and clinical features were analysed using a binary logistic regression model. In 27 of 87 patients (31%), a total of 67 venous complications were noted during the 3 months follow-up. Thrombosis represented the most frequently observed complication (n = 47; 70.1%), followed by vessel narrowing (n = 20; 29.9%). 5 (10.6%) of 47 thromboses showed spontaneous regression 3 months after IRE. A small vessel diameter (p = 0.011) and post-interventional vessel narrowing (p = 0.006) were independently associated with delayed post-ablative thrombosis. Delayed venous thrombosis frequently occurs after IRE of hepatic malignancies. Pre-existing vessel narrowing and a small vessel diameter represent significant risk factors that require further surveillance and potentially therapeutic intervention.


  • Open Access

    Color Coded Perfusion Imaging with Contrast Enhanced Ultrasound (CEUS) for Post-Interventional Success Control Following Irreversible Electroporation (IRE) of Primary and Secondary Malignant Liver Lesions

    by Janine Rennert, Isabel Wiesinger, Andreas Schicho, Philipp Wiggermann, Christian Stroszczynski, Lukas Philipp Beyer, Ernst Michael Jung

    Aim: Evaluation of the post-interventional success following irreversible electroporation (IRE) using a new color coded perfusion quantification software with contrast-enhanced ultrasound (CEUS) in patients with malignant lesions of the liver. Methods: Thirty-eight patients with 68 malignant liver lesions underwent IRE. All malignant lesions were investigated with CEUS before and within 24 hours following IRE to detect residual tumor tissue. The parameters analyzed by color coded perfusion quantification software were: the peak enhancement (pE), time to peak (TTP), mean transit time (mTT), rise (Ri) and wash-in area under the curve (WiAUC). Perfusion in the center, the margins of the lesions and in the surrounding liver were evaluated using these parameters. Results: Hepatocellular carcinoma (HCC) with complete ablation showed significantly different changes between the center and the margin of the lesions for WiAUC (p<0.05) and pE (p<0.01). Also significant differences were noted between the center of the lesions and the surrounded tissue for the same parameters (p<0.01). In the completely ablated metastatic lesions, significant differences were found between the center of the lesion and the margins (p < 0.01) and between the center of the lesion and the surrounding liver (p < 0.05) for WiAUC. mTT, TTP and Ri showed no significant changes between the center of the lesions, margin of the lesions or surrounding tissue. Also, no significant differences were found for these parameters in the different regions of interest for HCC or the metastatic lesions with partial ablation success. Conclusion: CEUS with perfusion imaging is a valuable supporting tool for the post-interventional evaluation of liver lesions following IRE. Focus should be placed on the peak enhancement (pE) and the wash-in area under the curve (WiAUC).