Blood flow characteristics in the ascending aorta after TAVI compared to surgical aortic valve replacement
- 22 October 2015
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 32 (3) , 461-467
Abstract
Ascending aortic blood flow characteristics are altered after aortic valve surgery, but the effect of transcatheter aortic valve implantation (TAVI) is unknown. Abnormal flow may be associated with aortic and cardiac remodeling. We analyzed blood flow characteristics in the ascending aorta after TAVI in comparison to conventional stented aortic bioprostheses (AVR) and healthy subjects using time-resolved three-dimensional flow-sensitive cardiovascular magnetic resonance imaging (4D-flow MRI). Seventeen patients with TAVI (Edwards Sapien XT), 12 with AVR and 9 healthy controls underwent 4D-flow MRI of the ascending aorta. Target parameters were: severity of vortical and helical flow pattern (semiquantitative grading from 0 = none to 3 = severe) and the local distribution of systolic wall shear stress (WSSsystole). AVR revealed significantly more extensive vortical and helical flow pattern than TAVI (p = 0.042 and p = 0.002) and controls (p < 0.001 and p = 0.001). TAVI showed significantly more extensive vortical flow than controls (p < 0.001). Both TAVI and AVR revealed marked blood flow eccentricity (64.7 and 66.7 %, respectively), whereas controls showed central blood flow (88.9 %). TAVI and AVR exhibited an asymmetric distribution of WSSsystole in the mid-ascending aorta with local maxima at the right anterior aortic wall and local minima at the left posterior wall. In contrast, controls showed a symmetric distribution of WSSsystole along the aortic circumference. Blood flow was significantly altered in the ascending aorta after TAVI and AVR. Changes were similar regarding WSSsystole distribution, while TAVI resulted in less helical and vortical blood flow.Keywords
Funding Information
- National Institutes of Health (NIH K25HL119608, R01HL115828)
This publication has 31 references indexed in Scilit:
- k‐t GRAPPA accelerated four‐dimensional flow MRI in the aorta: Effect on scan time, image quality, and quantification of flow and wall shear stressMagnetic Resonance in Medicine, 2013
- Assessment of valve haemodynamics, reverse ventricular remodelling and myocardial fibrosis following transcatheter aortic valve implantation compared to surgical aortic valve replacement: a cardiovascular magnetic resonance studyHeart, 2013
- 4D flow magnetic resonance imaging in bicuspid aortic valve disease demonstrates altered distribution of aortic blood flow helicityMagnetic Resonance in Medicine, 2013
- Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) Board of Trustees Task Force on Standardized Post ProcessingJournal of Cardiovascular Magnetic Resonance, 2013
- Cardiac and hepatic iron and ejection fraction in thalassemia major: Multicentre prospective comparison of combined Deferiprone and Deferoxamine therapy against Deferiprone or Deferoxamine MonotherapyJournal of Cardiovascular Magnetic Resonance, 2013
- Bicuspid Aortic Valve Is Associated With Altered Wall Shear Stress in the Ascending AortaCirculation: Cardiovascular Imaging, 2012
- Reproducibility of flow and wall shear stress analysis using flow‐sensitive four‐dimensional MRIJournal of Magnetic Resonance Imaging, 2011
- Comparison Between Transcatheter and Surgical Prosthetic Valve Implantation in Patients With Severe Aortic Stenosis and Reduced Left Ventricular Ejection FractionCirculation, 2010
- 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM Guidelines for the Diagnosis and Management of Patients with Thoracic Aortic DiseaseAnesthesia & Analgesia, 2010
- Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parametersMagnetic Resonance in Medicine, 2008