Florian von Knobelsdorff-Brenkenhoff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Florian von Knobelsdorff-Brenkenhoff has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- Jeanette Schulz-Menger
Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Deutschland
12 shared publications Jeanette Schulz-Menger
German Center for Cardiovascular Research (DZHK), Partner Site Berlin, Germany
10 shared publications- Matthias A. Dieringer
Department of Cardiology and Nephrology, Working Group on Cardiovascular Magnetic Resonance Imaging, Experimental and Clinical Research Center, Max-Delbrück-Centrum and Charité -Medical University Berlin and HELIOS Klinikum Berlin-Buch, Schwanebecker Chaussee 50, 13125, Berlin, Germany.
5 shared publications - Thoralf Niendorf
Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
5 shared publications - Andreas Greiser
Siemens Healthcare GmbH, Erlangen, Germany
4 shared publications J. Schulz-Menger
Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a Joint Cooperation Between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine, and HELIOS Klinikum Berlin Buch, Department of Cardiology and Nephrology, Schwanebecker Chaussee 50, Berlin 13125, Germany
4 shared publications
Latest Publications
- Open Access
- 1 January 2019
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 21 (1) , 25
Subclinical myocardial injury in patients with Facioscapulohumeral muscular dystrophy 1 and preserved ejection fraction – assessment by cardiovascular magnetic resonance
- 1 January 2019
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 21 (1) , 25
Open AccessSubclinical myocardial injury in patients with Facioscapulohumeral muscular dystrophy 1 and preserved ejection fraction – assessment by cardiovascular magnetic resonance
- 1 September 2016
- Vol. 25 (5) , 527-533
Cardiac Fibrosis in Aortic Stenosis and Hypertensive Heart Disease Assessed by Magnetic Resonance T1 Mapping.
Continuous pressure overload may lead to subclinical myocardial tissue changes in patients with hypertensive heart disease (HHD) and aortic stenosis (AS). The study aim was to detect interstitial fibrosis using quantitative cardiovascular magnetic resonance. Fifteen patients with HHD (arterial hypertension + septal wall thickness ≥13 mm), 33 with AS (eight mild, 15 moderate, 10 severe), and 60 healthy controls were enrolled. Native T1 maps (modified Look-Locker inversion recovery) were obtained in a basal, mid-ventricular, and apical shortaxis slice of the left ventricle to assess cardiac fibrosis. Focal fibrosis was assessed with late gadolinium enhancement (LGE). Patients with HHD and controls did not differ regarding the native myocardial T1 values, both per slice and per segment. In AS patients, apical native T1 values were lower than in controls, and there was a trend towards higher T1 values in the septum in severe AS (1172.6 ± 62.0 ms versus 1152.9 ± 43.9 ms). Five HHD patients and 11 AS patients had non-ischemic fibrosis in LGE images. Native T1 times did not differ between LGE-positive and LGEnegative groups (both with inclusion and exclusion of segments with LGE). T1 mapping did not reveal any evidence of abnormal interstitial fibrosis in HHD subjects with mild hypertrophy. In severe AS, a trend towards more interstitial fibrosis was present, but absolute differences were small for decision making.
- 1 September 2016
- Vol. 25 (5) , 527-533
Cardiac Fibrosis in Aortic Stenosis and Hypertensive Heart Disease Assessed by Magnetic Resonance T1 Mapping.
Continuous pressure overload may lead to subclinical myocardial tissue changes in patients with hypertensive heart disease (HHD) and aortic stenosis (AS). The study aim was to detect interstitial fibrosis using quantitative cardiovascular magnetic resonance. Fifteen patients with HHD (arterial hypertension + septal wall thickness ≥13 mm), 33 with AS (eight mild, 15 moderate, 10 severe), and 60 healthy controls were enrolled. Native T1 maps (modified Look-Locker inversion recovery) were obtained in a basal, mid-ventricular, and apical shortaxis slice of the left ventricle to assess cardiac fibrosis. Focal fibrosis was assessed with late gadolinium enhancement (LGE). Patients with HHD and controls did not differ regarding the native myocardial T1 values, both per slice and per segment. In AS patients, apical native T1 values were lower than in controls, and there was a trend towards higher T1 values in the septum in severe AS (1172.6 ± 62.0 ms versus 1152.9 ± 43.9 ms). Five HHD patients and 11 AS patients had non-ischemic fibrosis in LGE images. Native T1 times did not differ between LGE-positive and LGEnegative groups (both with inclusion and exclusion of segments with LGE). T1 mapping did not reveal any evidence of abnormal interstitial fibrosis in HHD subjects with mild hypertrophy. In severe AS, a trend towards more interstitial fibrosis was present, but absolute differences were small for decision making.
- 20 August 2016
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 30 (1) , 85-91
Influence of spatial resolution and contrast agent dosage on myocardial T1 relaxation times
Objective Our aim was to study the influence of small variations in spatial resolution and contrast agent dosage on myocardial T1 relaxation time. Materials and methods Twenty-nine healthy volunteers underwent cardiovascular magnetic resonance at 3T twice, including a modified look-locker inversion recovery (MOLLI) technique—3(3)3(3)5—for T1 mapping. Native T1 was assessed in three spatial resolutions (voxel size 1.4 × 1.4 × 6, 1.6 × 1.6 × 6, 1.7 × 1.7 × 6 mm3), and postcontrast T1 after 0.1 and 0.2 mmol/kg gadobutrol. Partition coefficient was calculated based on myocardial and blood T1. T1 analysis was done per segment, per slice, and for the whole heart. Results Native T1 values did not differ with varying spatial resolution per segment (p = 0.116–0.980), per slice (basal: p = 0.772; middle: p = 0.639; apex: p = 0.276), and globally (p = 0.191). Postcontrast T1 values were significantly lower with higher contrast agent dosage (p < 0.001). The global partition coefficient was 0.43 ± 0.3 for 0.2 and 0.1 mmol gadobutrol (p = 0.079). Conclusion Related to the tested MOLLI technique at 3T, very small variations in spatial resolution (voxel sizes between 1.4 × 1.4 × 6 and 1.7 × 1.7 × 6 mm3) remained without effect on the native T1 relaxation times. Postcontrast T1 values were naturally shorter with higher contrast agent dosage while the partition coefficient remained constant. Further studies are necessary to test whether these conclusions hold true for larger matrix sizes and in larger cohorts.
- 20 August 2016
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 30 (1) , 85-91
Influence of spatial resolution and contrast agent dosage on myocardial T1 relaxation times
Objective Our aim was to study the influence of small variations in spatial resolution and contrast agent dosage on myocardial T1 relaxation time. Materials and methods Twenty-nine healthy volunteers underwent cardiovascular magnetic resonance at 3T twice, including a modified look-locker inversion recovery (MOLLI) technique—3(3)3(3)5—for T1 mapping. Native T1 was assessed in three spatial resolutions (voxel size 1.4 × 1.4 × 6, 1.6 × 1.6 × 6, 1.7 × 1.7 × 6 mm3), and postcontrast T1 after 0.1 and 0.2 mmol/kg gadobutrol. Partition coefficient was calculated based on myocardial and blood T1. T1 analysis was done per segment, per slice, and for the whole heart. Results Native T1 values did not differ with varying spatial resolution per segment (p = 0.116–0.980), per slice (basal: p = 0.772; middle: p = 0.639; apex: p = 0.276), and globally (p = 0.191). Postcontrast T1 values were significantly lower with higher contrast agent dosage (p < 0.001). The global partition coefficient was 0.43 ± 0.3 for 0.2 and 0.1 mmol gadobutrol (p = 0.079). Conclusion Related to the tested MOLLI technique at 3T, very small variations in spatial resolution (voxel sizes between 1.4 × 1.4 × 6 and 1.7 × 1.7 × 6 mm3) remained without effect on the native T1 relaxation times. Postcontrast T1 values were naturally shorter with higher contrast agent dosage while the partition coefficient remained constant. Further studies are necessary to test whether these conclusions hold true for larger matrix sizes and in larger cohorts.
- Open Access
- 29 April 2016
- Published by Springer Nature in BMC Medical Imaging
- Vol. 16 (1) , 35
Current T1 and T2 mapping techniques applied with simple thresholds cannot discriminate acute from chronic myocadial infarction on an individual patient basis: a pilot study
Studying T1- and T2-mapping for discrimination of acute from chronic myocardial infarction (AMI, CMI). Eight patients with AMI underwent CMR at 3 T acutely and after >3 months. Imaging techniques included: T2-weighted imaging, late enhancement (LGE), T2-mapping, native and post-contrast T1-mapping. Myocardial T2- and T1-relaxation times were determined for every voxel. Abnormal voxels as defined by having T2- and T1-values beyond a predefined threshold (T2 > 50 ms, native T1 > 1250 ms and post-contrast T1 < 350 ms) were highlighted and compared with LGE as the reference. Abnormal T2-relaxation times were present in the voxels with AMI (=> delete acute infarction; unfortunately this is not possible in your web interface) acute infarction only in half of the subjects. Abnormal T2-values were also present in subjects with CMI, thereby matching the chronically infarcted territory in some. Abnormal native T1 times were present in voxels with AMI in 5/8 subjects, but also remote from the infarcted territory in four. In CMI, abnormal native T1 values corresponded with infarcted voxels, but were also abnormal remote from the infarcted territory. Voxels with abnormal post-contrast T1-relaxation times agreed well with LGE in AMI and CMI. In this pilot-study, T2- and T1-mapping with simple thresholds did not facilitate the discrimination of AMI and CMI.
- 29 April 2016
- Published by Springer Nature in BMC Medical Imaging
- Vol. 16 (1) , 35
Open AccessCurrent T1 and T2 mapping techniques applied with simple thresholds cannot discriminate acute from chronic myocadial infarction on an individual patient basis: a pilot study
Studying T1- and T2-mapping for discrimination of acute from chronic myocardial infarction (AMI, CMI). Eight patients with AMI underwent CMR at 3 T acutely and after >3 months. Imaging techniques included: T2-weighted imaging, late enhancement (LGE), T2-mapping, native and post-contrast T1-mapping. Myocardial T2- and T1-relaxation times were determined for every voxel. Abnormal voxels as defined by having T2- and T1-values beyond a predefined threshold (T2 > 50 ms, native T1 > 1250 ms and post-contrast T1 < 350 ms) were highlighted and compared with LGE as the reference. Abnormal T2-relaxation times were present in the voxels with AMI (=> delete acute infarction; unfortunately this is not possible in your web interface) acute infarction only in half of the subjects. Abnormal T2-values were also present in subjects with CMI, thereby matching the chronically infarcted territory in some. Abnormal native T1 times were present in voxels with AMI in 5/8 subjects, but also remote from the infarcted territory in four. In CMI, abnormal native T1 values corresponded with infarcted voxels, but were also abnormal remote from the infarcted territory. Voxels with abnormal post-contrast T1-relaxation times agreed well with LGE in AMI and CMI. In this pilot-study, T2- and T1-mapping with simple thresholds did not facilitate the discrimination of AMI and CMI.
- 1 March 2016
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 9 (3) , e004038
Evaluation of Aortic Blood Flow and Wall Shear Stress in Aortic Stenosis and Its Association With Left Ventricular Remodeling
Background—: Aortic stenosis (AS) leads to variable stress for the left ventricle (LV) and consequently a broad range of LV remodeling. The aim of this study was to describe blood flow patterns in the ascending aorta of patients with AS and determine their association with remodeling. Methods and Results—: Thirty-seven patients with AS (14 mild, 8 moderate, 15 severe; age, 63±13 years) and 37 healthy controls (age, 60±10 years) underwent 4-dimensional-flow magnetic resonance imaging. Helical and vortical flow formations and flow eccentricity were assessed in the ascending aorta. Normalized flow displacement from the vessel center and peak systolic wall shear stress in the ascending aorta were quantified. LV remodeling was assessed based on LV mass index and the ratio of LV mass:end-diastolic volume (relative wall mass). Marked helical and vortical flow formation and eccentricity were more prevalent in patients with AS than in healthy subjects, and patients with AS exhibited an asymmetrical and elevated distribution of peak systolic wall shear stress. In AS, aortic orifice area was strongly negatively associated with vortical flow formation ( P =0.0274), eccentricity ( P =0.0070), and flow displacement ( P =0.0021). Bicuspid aortic valve was associated with more intense helical ( P =0.0098) and vortical flow formation ( P =0.0536), higher flow displacement ( P =0.11), and higher peak systolic wall shear stress ( P =0.0926). LV mass index and relative wall mass were significantly associated with aortic orifice area ( P =0.0611, P =0.0058) and flow displacement ( P =0.0058, P =0.0283). Conclusions—: In this pilot study, AS leads to abnormal blood flow pattern and peak systolic wall shear stress in the ascending aorta. In addition to aortic orifice area, normalized flow displacement was significantly associated with LV remodeling.
- 1 March 2016
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 9 (3) , e004038
Evaluation of Aortic Blood Flow and Wall Shear Stress in Aortic Stenosis and Its Association With Left Ventricular Remodeling
Background—: Aortic stenosis (AS) leads to variable stress for the left ventricle (LV) and consequently a broad range of LV remodeling. The aim of this study was to describe blood flow patterns in the ascending aorta of patients with AS and determine their association with remodeling. Methods and Results—: Thirty-seven patients with AS (14 mild, 8 moderate, 15 severe; age, 63±13 years) and 37 healthy controls (age, 60±10 years) underwent 4-dimensional-flow magnetic resonance imaging. Helical and vortical flow formations and flow eccentricity were assessed in the ascending aorta. Normalized flow displacement from the vessel center and peak systolic wall shear stress in the ascending aorta were quantified. LV remodeling was assessed based on LV mass index and the ratio of LV mass:end-diastolic volume (relative wall mass). Marked helical and vortical flow formation and eccentricity were more prevalent in patients with AS than in healthy subjects, and patients with AS exhibited an asymmetrical and elevated distribution of peak systolic wall shear stress. In AS, aortic orifice area was strongly negatively associated with vortical flow formation ( P =0.0274), eccentricity ( P =0.0070), and flow displacement ( P =0.0021). Bicuspid aortic valve was associated with more intense helical ( P =0.0098) and vortical flow formation ( P =0.0536), higher flow displacement ( P =0.11), and higher peak systolic wall shear stress ( P =0.0926). LV mass index and relative wall mass were significantly associated with aortic orifice area ( P =0.0611, P =0.0058) and flow displacement ( P =0.0058, P =0.0283). Conclusions—: In this pilot study, AS leads to abnormal blood flow pattern and peak systolic wall shear stress in the ascending aorta. In addition to aortic orifice area, normalized flow displacement was significantly associated with LV remodeling.
- Open Access
- 22 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 1-18
Role of cardiovascular magnetic resonance in the guidelines of the European Society of Cardiology
- 22 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 1-18
Open AccessRole of cardiovascular magnetic resonance in the guidelines of the European Society of Cardiology
- Open Access
- 21 December 2015
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (1) , 168-177
Myocardial dysfunction in patients with aortic stenosis and hypertensive heart disease assessed by MR tissue phase mapping
Purpose To identify abnormalities of myocardial velocities in patients with left ventricular pressure overload using magnetic resonance tissue phase mapping (TPM). Material and Methods Thirty-three patients (nine with hypertensive heart disease [HYP], 24 with aortic stenosis [AS]) and 41 healthy controls were enrolled. To assess left ventricular motion, a basal, midventricular, and apical slice were acquired using three-directional velocity-encoded phase-contrast MR with a 3T system. Target parameters were peak longitudinal (Vz) and radial (Vr) velocity in systole and diastole (Peaksys, Peakdias). Analysis was done on each myocardial segment. In a subgroup (n = 7 HYP, n = 12 AS, n = 24 controls), measurement was repeated during handgrip exercise. Results AS had significantly lower Vz-Peaksys in the inferolateral and inferoseptal wall (P = 0.003–0.029) and Vr-Peaksys in the septum and anterior wall (P = 0.001–0.013) than controls. Vz-Peakdias and Vr-Peakdias were lower in AS than in controls in almost all segments (P < 0.001–0.028). HYP showed reduced Vz-Peakdias compared to controls in all basal segments as well as in the lateral midventricular wall (P < 0.001–0.045), and reduced Vr-Peakdias compared to controls predominantly in the midventricular and apical segments (P = 0.004–0.042). AS patients with focal fibrosis had significantly reduced myocardial velocities (P = 0.001–0.047) in segments without late enhancement. During exercise, Vz-Peaksys, Vr-Peaksys, and Vz-Peakdias remained unchanged in AS and HYP, but decreased in the lateral wall in controls (P < 0.001–0.043). Conclusion Even with preserved left ventricle (LV) ejection fraction, peak longitudinal and radial velocities of the LV are reduced in AS and HYP, indicating early functional impairment. J. Magn. Reson. Imaging 2016;44:168–177.
- 21 December 2015
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (1) , 168-177
Open AccessMyocardial dysfunction in patients with aortic stenosis and hypertensive heart disease assessed by MR tissue phase mapping
Purpose To identify abnormalities of myocardial velocities in patients with left ventricular pressure overload using magnetic resonance tissue phase mapping (TPM). Material and Methods Thirty-three patients (nine with hypertensive heart disease [HYP], 24 with aortic stenosis [AS]) and 41 healthy controls were enrolled. To assess left ventricular motion, a basal, midventricular, and apical slice were acquired using three-directional velocity-encoded phase-contrast MR with a 3T system. Target parameters were peak longitudinal (Vz) and radial (Vr) velocity in systole and diastole (Peaksys, Peakdias). Analysis was done on each myocardial segment. In a subgroup (n = 7 HYP, n = 12 AS, n = 24 controls), measurement was repeated during handgrip exercise. Results AS had significantly lower Vz-Peaksys in the inferolateral and inferoseptal wall (P = 0.003–0.029) and Vr-Peaksys in the septum and anterior wall (P = 0.001–0.013) than controls. Vz-Peakdias and Vr-Peakdias were lower in AS than in controls in almost all segments (P < 0.001–0.028). HYP showed reduced Vz-Peakdias compared to controls in all basal segments as well as in the lateral midventricular wall (P < 0.001–0.045), and reduced Vr-Peakdias compared to controls predominantly in the midventricular and apical segments (P = 0.004–0.042). AS patients with focal fibrosis had significantly reduced myocardial velocities (P = 0.001–0.047) in segments without late enhancement. During exercise, Vz-Peaksys, Vr-Peaksys, and Vz-Peakdias remained unchanged in AS and HYP, but decreased in the lateral wall in controls (P < 0.001–0.043). Conclusion Even with preserved left ventricle (LV) ejection fraction, peak longitudinal and radial velocities of the LV are reduced in AS and HYP, indicating early functional impairment. J. Magn. Reson. Imaging 2016;44:168–177.
- Open Access
- 17 November 2015
- Published by Springer Nature in BMC Medical Imaging
- Vol. 15 (1) , 1-10
Prospective, randomized comparison of gadopentetate and gadobutrol to assess chronic myocardial infarction applying cardiovascular magnetic resonance
We hypothesized that the contrast medium gadobutrol is not inferior compared to Gd-DTPA in identifying and quantifying ischemic late gadolinium enhancement (LGE), even by using a lower dose. We prospectively enrolled 30 patients with chronic myocardial infarction as visualized by LGE during clinical routine scan at 1.5 T with 0.20 mmol/kg Gd-DTPA. Participants were randomized to either 0.15 mmol/kg gadobutrol (group A) or 0.10 mmol/kg gadobutrol (group B). CMR protocol was identical in both exams. LGE was quantified using a semiautomatic approach. Signal intensities of scar, remote myocardium, blood and air were measured. Signal to noise (SNR) and contrast to noise ratios (CNR) were calculated. Signal intensities were not different between Gd-DTPA and gadobutrol in group A, whereas significant differences were detected in group B. SNR of injured myocardium (53.5+/−21.4 vs. 30.1+/−10.4, p = 0.0001) and CNR between injured and remote myocardium (50.3+/−20.3 vs. 27.3+/−9.3, p < 0.0001) were lower in gadobutrol. Infarct size was lower in both gadobutrol groups compared to Gd-DTPA (group A: 16.8+/−10.2 g vs. 12.8+/−6.8 g, p = 0.03; group B: 18.6+/−12.0 g vs. 14.0+/−9.9 g, p = 0.0016). Taking application of 0.2 mmol/kg Gd-DTPA as the reference, the delineation of infarct scar was similar with 0.15 mmol/kg gadobutrol, whereas the use 0.10 mmol/kg gadobutrol led to reduced tissue contrast. The study had been registered under EudraCT Number: 2010-020775-22 . Registration date: 2010.08.10
- 17 November 2015
- Published by Springer Nature in BMC Medical Imaging
- Vol. 15 (1) , 1-10
Open AccessProspective, randomized comparison of gadopentetate and gadobutrol to assess chronic myocardial infarction applying cardiovascular magnetic resonance
We hypothesized that the contrast medium gadobutrol is not inferior compared to Gd-DTPA in identifying and quantifying ischemic late gadolinium enhancement (LGE), even by using a lower dose. We prospectively enrolled 30 patients with chronic myocardial infarction as visualized by LGE during clinical routine scan at 1.5 T with 0.20 mmol/kg Gd-DTPA. Participants were randomized to either 0.15 mmol/kg gadobutrol (group A) or 0.10 mmol/kg gadobutrol (group B). CMR protocol was identical in both exams. LGE was quantified using a semiautomatic approach. Signal intensities of scar, remote myocardium, blood and air were measured. Signal to noise (SNR) and contrast to noise ratios (CNR) were calculated. Signal intensities were not different between Gd-DTPA and gadobutrol in group A, whereas significant differences were detected in group B. SNR of injured myocardium (53.5+/−21.4 vs. 30.1+/−10.4, p = 0.0001) and CNR between injured and remote myocardium (50.3+/−20.3 vs. 27.3+/−9.3, p < 0.0001) were lower in gadobutrol. Infarct size was lower in both gadobutrol groups compared to Gd-DTPA (group A: 16.8+/−10.2 g vs. 12.8+/−6.8 g, p = 0.03; group B: 18.6+/−12.0 g vs. 14.0+/−9.9 g, p = 0.0016). Taking application of 0.2 mmol/kg Gd-DTPA as the reference, the delineation of infarct scar was similar with 0.15 mmol/kg gadobutrol, whereas the use 0.10 mmol/kg gadobutrol led to reduced tissue contrast. The study had been registered under EudraCT Number: 2010-020775-22 . Registration date: 2010.08.10
- 22 October 2015
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 32 (3) , 461-467
Blood flow characteristics in the ascending aorta after TAVI compared to surgical aortic valve replacement
Ascending aortic blood flow characteristics are altered after aortic valve surgery, but the effect of transcatheter aortic valve implantation (TAVI) is unknown. Abnormal flow may be associated with aortic and cardiac remodeling. We analyzed blood flow characteristics in the ascending aorta after TAVI in comparison to conventional stented aortic bioprostheses (AVR) and healthy subjects using time-resolved three-dimensional flow-sensitive cardiovascular magnetic resonance imaging (4D-flow MRI). Seventeen patients with TAVI (Edwards Sapien XT), 12 with AVR and 9 healthy controls underwent 4D-flow MRI of the ascending aorta. Target parameters were: severity of vortical and helical flow pattern (semiquantitative grading from 0 = none to 3 = severe) and the local distribution of systolic wall shear stress (WSSsystole). AVR revealed significantly more extensive vortical and helical flow pattern than TAVI (p = 0.042 and p = 0.002) and controls (p < 0.001 and p = 0.001). TAVI showed significantly more extensive vortical flow than controls (p < 0.001). Both TAVI and AVR revealed marked blood flow eccentricity (64.7 and 66.7 %, respectively), whereas controls showed central blood flow (88.9 %). TAVI and AVR exhibited an asymmetric distribution of WSSsystole in the mid-ascending aorta with local maxima at the right anterior aortic wall and local minima at the left posterior wall. In contrast, controls showed a symmetric distribution of WSSsystole along the aortic circumference. Blood flow was significantly altered in the ascending aorta after TAVI and AVR. Changes were similar regarding WSSsystole distribution, while TAVI resulted in less helical and vortical blood flow.
- 22 October 2015
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 32 (3) , 461-467
Blood flow characteristics in the ascending aorta after TAVI compared to surgical aortic valve replacement
Ascending aortic blood flow characteristics are altered after aortic valve surgery, but the effect of transcatheter aortic valve implantation (TAVI) is unknown. Abnormal flow may be associated with aortic and cardiac remodeling. We analyzed blood flow characteristics in the ascending aorta after TAVI in comparison to conventional stented aortic bioprostheses (AVR) and healthy subjects using time-resolved three-dimensional flow-sensitive cardiovascular magnetic resonance imaging (4D-flow MRI). Seventeen patients with TAVI (Edwards Sapien XT), 12 with AVR and 9 healthy controls underwent 4D-flow MRI of the ascending aorta. Target parameters were: severity of vortical and helical flow pattern (semiquantitative grading from 0 = none to 3 = severe) and the local distribution of systolic wall shear stress (WSSsystole). AVR revealed significantly more extensive vortical and helical flow pattern than TAVI (p = 0.042 and p = 0.002) and controls (p < 0.001 and p = 0.001). TAVI showed significantly more extensive vortical flow than controls (p < 0.001). Both TAVI and AVR revealed marked blood flow eccentricity (64.7 and 66.7 %, respectively), whereas controls showed central blood flow (88.9 %). TAVI and AVR exhibited an asymmetric distribution of WSSsystole in the mid-ascending aorta with local maxima at the right anterior aortic wall and local minima at the left posterior wall. In contrast, controls showed a symmetric distribution of WSSsystole along the aortic circumference. Blood flow was significantly altered in the ascending aorta after TAVI and AVR. Changes were similar regarding WSSsystole distribution, while TAVI resulted in less helical and vortical blood flow.
- 19 July 2015
- Published by Springer Nature in European Radiology
- Vol. 26 (4) , 986-996
Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patients
Assessment of haemodynamics is crucial in many cardiac diseases. Phase contrast MRI (PC-MRI) can accurately access it. Arrhythmia is a major limitation in conventional segmented PC-MRI (SEG). A real-time PC-MRI sequence (RT) could overcome this. We validated RT by comparing to SEG. A prototype RT using shared velocity encoding was tested against SEG at 1.5 T in a flow phantom and consecutively included patients with (n = 55) or without (n = 59) aortic valve disease. In patients with atrial fibrillation (Afib, n = 15), only RT was applied. Phantom: PC images were acquired in front of and behind an interchangeable aortic-stenosis-like inlay. Mean velocity and flow were quantified. Patients: PC images were acquired in the ascending aorta, pulmonary trunk and superior caval vein. Peak velocity, stroke volume and regurgitant fraction were quantified. Phantom: Mean velocities (11 ± 1 to 207 ± 10 cm/s) and flow correlated closely between SEG and RT (r ≥ 0.99, ICC ≥ 0.98, p < 0.0005). Patients without AVD or with aortic regurgitation: Concordance of SEG and RT was excellent regarding peak velocities, stroke volumes (r ≥ 0.91, ICC ≥ 0.94, p < 0.0005) and regurgitant fractions (r = 0.95, ICC = 0.95, p < 0.0005). RT was feasible in all patients with Afib. The real-time sequence is accurate compared to conventional segmented PC-MRI. Its applicability in Afib was shown. Real-time PC-MRI might become a valuable tool in arrhythmia. • Assessment of haemodynamics is crucial in many cardiac diseases. • Arrhythmias are a major limitation of conventional techniques in cardiac magnetic resonance. • A real-time technique, which allows application in arrhythmia, was validated. • This real-time technique might become a valuable tool in arrhythmic patients.
- 19 July 2015
- Published by Springer Nature in European Radiology
- Vol. 26 (4) , 986-996
Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patients
Assessment of haemodynamics is crucial in many cardiac diseases. Phase contrast MRI (PC-MRI) can accurately access it. Arrhythmia is a major limitation in conventional segmented PC-MRI (SEG). A real-time PC-MRI sequence (RT) could overcome this. We validated RT by comparing to SEG. A prototype RT using shared velocity encoding was tested against SEG at 1.5 T in a flow phantom and consecutively included patients with (n = 55) or without (n = 59) aortic valve disease. In patients with atrial fibrillation (Afib, n = 15), only RT was applied. Phantom: PC images were acquired in front of and behind an interchangeable aortic-stenosis-like inlay. Mean velocity and flow were quantified. Patients: PC images were acquired in the ascending aorta, pulmonary trunk and superior caval vein. Peak velocity, stroke volume and regurgitant fraction were quantified. Phantom: Mean velocities (11 ± 1 to 207 ± 10 cm/s) and flow correlated closely between SEG and RT (r ≥ 0.99, ICC ≥ 0.98, p < 0.0005). Patients without AVD or with aortic regurgitation: Concordance of SEG and RT was excellent regarding peak velocities, stroke volumes (r ≥ 0.91, ICC ≥ 0.94, p < 0.0005) and regurgitant fractions (r = 0.95, ICC = 0.95, p < 0.0005). RT was feasible in all patients with Afib. The real-time sequence is accurate compared to conventional segmented PC-MRI. Its applicability in Afib was shown. Real-time PC-MRI might become a valuable tool in arrhythmia. • Assessment of haemodynamics is crucial in many cardiac diseases. • Arrhythmias are a major limitation of conventional techniques in cardiac magnetic resonance. • A real-time technique, which allows application in arrhythmia, was validated. • This real-time technique might become a valuable tool in arrhythmic patients.